Wei Yue

Wei Yue

Auto-generated profile, based on publicly available information

Wei Yue

Radio Frequency Integrated Circuit Center, Kwangwoon University, Wolgye-Dong, Nowon-Ku, Seoul 139-701, Korea

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
WYWei Yue
Wei Yue
EKEun Seong Kim
Eun Seong Kim
BZBAOHUA ZHU
BAOHUA ZHU
JCJIAN CHEN
JIAN CHEN
Jun-Ge LiangJun-Ge Liang
Jun-Ge Liang
Nam Young KimNam Young Kim
Nam Young Kim
In this study, we propose a high-performance resonator-based biosensor for mediator-free glucose identification. The biosensor is characterized by an air-bridge capacitor and fabricated via integrated passive device technology on gallium arsenide (GaAs) substrate. The exterior design of the structure is a spiral inductor with the air-bridge providing a sensitive surface, whereas the internal capacitor improves indicator performance. The sensing relies on repolarization and rearrangement of surface molecules, which are excited by the dropped sample at the microcosmic level, and the resonance performance variation corresponds to the difference in glucose concentration at the macroscopic level. The air-bridge capacitor in the modeled RLC circuit serves as a bio-recognition element to glucose concentration (εglucoseC0), generating resonant frequency shifts at 0.874 GHz and 1.244 GHz for concentrations of 25 mg/dL and 300 mg/dL compared to DI water, respectively. The proposed biosensor exhibits excellent sensitivity at 1.38 MHz per mg/dL with a wide detection range for glucose concentrations of 25–300 mg/dL and a low detection limit of 24.59 mg/dL. Additionally, the frequency shift and concentration are highly linear with a coefficient of determination of 0.98823. The response time is less than 3 s. We performed multiple experiments to verify that the surface morphology reveals no deterioration and chemical binding, thus validating the reusability and reliability of the proposed biosensor.

21 January 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
JCJIAN CHEN
JIAN CHEN
BZBAOHUA ZHU
BAOHUA ZHU
SYShan Yang
Shan Yang
WYWei Yue
Wei Yue
DLDong-Min Lee
Dong-Min Lee
Nam Young KimNam Young Kim
Nam Young Kim
In this study, we propose a miniaturized bandpass filter (BPF) developed by combining an approximate circular (36-gon) winding inductor, a circinate capacitor, and five air-bridge structures fabricated on a gallium arsenide (GaAs) substrate using an integrated passive device (IPD) technology. We introduced air-bridge structures into the outer metal wire to improve the capacitance per unit volume while utilizing a miniaturized chip with dimensions 1538 μm × 800 μm (0.029 λ0 × 0.015 λ0) for the BPF. The pattern was designed and optimized by simulating different dimensional parameters, and the group delay and current density are presented. The equivalent circuit was modeled to analysis various parasitic effect. Additionally, we described the GaAs-based micro-nano scale fabrication process to elucidate the proposed IPD technology and the physical structure of the BPF. Measurements were conducted with a center frequency of 1.53 GHz (insertion loss of 0.53 dB) and a 3-dB fractional bandwidth (FBW) of 70.59%. The transmission zero was located at 4.16 GHz with restraint of 35.86 dB. Owing to the benefits from its miniaturized chip size and high performance, the proposed GaAs-based IPD BPF was verified as an excellent device for various S-band applications, such as satellite communication, keyless vehicle locks, wireless headphones, and radar.