Dmytro Usenko

Dmytro Usenko

Auto-generated profile, based on publicly available information

Dmytro Usenko

Національний університет «Полтавська політехніка імені Юрія Кондратюка

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2021 in Збірник наукових праць Галузеве машинобудування будівництво/ Academic journal Industrial Machine Building Civil Engineering
Verified
Journal Article
Open access
PDF file
ODOksana Dovzhenko
Oksana Dovzhenko
VPVolodymyr Pohribnyi
Volodymyr Pohribnyi
VUValery Usenko
Valery Usenko
DUDmytro Usenko
Dmytro Usenko
Possible causes of destruction of masonry in buildings with bearing masonry walls under the combined effect of vertical and horizontal loads are considered. The diagonal shear is highlighted as a typical case for partitions under seismic impacts. Based on the analysis of the results of experimental studies of samples for skewing, as models of the operation of the partition, proposals are presented for a kinematically possible scheme of the masonry elements destruction, which is proposed as a base for the calculation. The strength problem was solved by the variational method in the theory of plasticity, taking into account both strength characteristics of the masonry, the dimensions of the samples, and the loading areas. The peculiarities of the masonry work are taken into account by using the appropriate strength condition. The influence on the strength of reinforcement of masonry partitions during diagonal splitting is considered.

17 December 2025 in Nuclear and Radiation Safety
Verified
Journal Article
Closed access
АГА. В. Гасенко
А. В. Гасенко
Dmytro OvsiiDmytro Ovsii
Dmytro Ovsii
PSPavlo Semko
Pavlo Semko
ДУД. В. Усенко
Д. В. Усенко
Ядерна безпека є одним з важливих питань для будь-якої країни. Умови повномасштабної війни в Україні різко загострили питання реальної захисної спроможності укриттів, які масово облаштовують у підвальних і цокольних приміщеннях без належної перевірки відповідності властивостям захисних споруд цивільного захисту, зокрема і протирадіаційних укриттів. Навіть наявні протирадіаційні укриття, споруджені ще в минулому столітті, потребують перегляду відповідності сучасним вимогам щодо несучої здатності та послаблення іонізуючого випромінювання. У статті на конкретному об’єкті показано, як системна оцінка дозволяє встановити фактичну відповідність / невідповідність підвального приміщення будівлі ознакам протирадіаційного укриття за ДБН В.2.2-5:2023. Методика оцінки охоплювала натурне обстеження, аналіз об’ємно-планувальних рішень й інженерних систем, перевірні розрахунки несучої здатності конструкцій, визначення коефіцієнта послаблення іонізуючого випромінювання. Результати засвідчили низку критичних невідповідностей: відсутність механічної вентиляції, захисних дверей та аварійних виходів; дефіцит площі основних приміщень, обов’язкових допоміжних приміщень і санітарно-гігієнічного обладнання; прокладання мереж без захисних футлярів. За розрахунками несуча здатність плит перекриття і стін є недостатньою на повне еквівалентне навантаження у 22 рази та 1,5 раза відповідно, а коефіцієнт послаблення випромінювання у сотні разів нижчий за нормативний; навіть після первинних заходів (влаштування тамбурів, закладення прорізів, зовнішнього обвалування стін) показник залишається у 8–20 разів меншим за вимогу. Практичне значення роботи полягає в демонстрації проведення перевірок, що дозволяє органам місцевого самоврядування, балансоутримувачам та проєктантам ідентифікувати «вузькі місця» типових підвальних укриттів й обґрунтовано планувати підсилення конструкцій і комплектацію інженерних систем до досягнення нормативної відповідності.

22 September 2018 in Molecular Crystals and Liquid Crystals
Verified
Journal Article
Closed access
VSV. V. Soloviev
V. V. Soloviev
LSL. A. Solyanik
L. A. Solyanik
TKT. Yu. Kuznetsova
T. Yu. Kuznetsova
YHYu. S. Holik
Yu. S. Holik
OIO. E. Illyash
O. E. Illyash
DUD. V. Usenko
D. V. Usenko
On the basis of ab initio analysis of the calculation of impact of the cation composition tungstate-containing melt on structural peculiarities of EAP, the differences in the structure at implementation of sequential and simultaneous six-electron transfer are determined. According to the results of calculations of charge on the atoms of “isolated” tungstate-ion during transfer of 6 electrons in the electrode reaction on “isolated” tungstate-anion, the W atom is the only centre of electronic attack. At the electroreduction of cationised complexes, the electron charge is transferred to the cations and to the W atom, indicating the existence of two centres of electronic attack.

23 September 2021
Verified
Book Chapter
Closed access
PDF file
VPVolodymyr Pohribnyi
Volodymyr Pohribnyi
ODOksana Dovzhenko
Oksana Dovzhenko
OFOleksiy Fenko
Oleksiy Fenko
DUDmytro Usenko
Dmytro Usenko

28 August 2025 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
AHAnton Hasenko
Anton Hasenko
DUDmytro Usenko
Dmytro Usenko
PSPavlo Semko
Pavlo Semko
Dmytro OvsiiDmytro Ovsii
Dmytro Ovsii
This study’s object is brick structures for multi-story residential construction. In such buildings it is necessary to arrange built-in protective structures for civil defense. As a result of prolonged temperature and humidity exposure, wetting and destruction of brickwork may occur. Solving this problem requires devising measures to isolate brickwork from external influences, as well as, if necessary, options for strengthening damaged structures. One of the results of this work is the identification of principal damage based on analysis of the consequences of prolonged temperature and humidity exposure to complexly loaded brick structures (walls, partitions, columns) of a public facility. This is frost-related damage up to 40% of the initial cross-section, which is mainly associated with different porosity of the brick and the influence of atmospheric precipitation. The next result of the work is proposals for increasing the bearing capacity of damaged brickwork using tie clips from rolled steel elements. A qualitative feature of the proposal is the recommendations for installing these clips, which allow them to be included in joint work with existing brick elements. This qualitative distinctive feature was confirmed by mathematical numerical modeling of the increase in the bearing capacity of reinforcement brick structures. From a scientific perspective, different initial stress-strain states of brick structures and steel elements at the time of ensuring their joint operation were taken into account. After the installation of steel clips, the maximum compressive stresses in the brickwork decreased by 28.6%. The results could be applied when installing reinforcements with steel clips for damaged compressed brick structures

4 September 2023 in Municipal economy of cities
Verified
Journal Article
Open access
PDF file
Oleksandr SemkoOleksandr Semko
Oleksandr Semko
NPN. Pinchuk
N. Pinchuk
DUD. Usenko
D. Usenko
The article provides valuable information on methods for assessing the reliability of stone structures. The authors draw attention to the issues of diagnostics and calculation of the reliability of existing masonry structures, and also offer methods for determining the compressive strength of masonry using the theory of reliability. The destructive and non-destructive tests underlying the determination of strength masonry are also described. The authors emphasize the importance of structural safety and reliability, which depend on many factors, including the type and magnitude of loads and the bearing capacity of structural elements. A sufficient state of safety is ensured by compliance with the relevant standards and regulations. The article draws attention to the importance of carrying out tests and calculations in the reconstruction and repair of buildings in order to guarantee their safe operation. The authors note that the safety and reliability of the design also depends on compliance with the rules and regulations that take into account the social, economic and environmental consequences of failure. The emphasis on the probabilistic approach to assessing the reliability of a design is an important aspect of the article. Taking into account the probability of failure allows us to develop a rational approach to the repair and reconstruction of buildings, ensuring their normal operation. The authors also draw attention to the importance of determining the probability of failure (Pf) as a fundamental parameter for its assessment. Keywords: reliability assessment, masonry structures, masonry strength, structural safety, safety factors, deformations, fire resistance, reliability theory, failure probability.