The stress-strain state and the bearing capacity of the dismountable joints of concrete filled tubular elements are investigated. The methods of calculation and constructive solutions of concrete filled tubular elements with joints are analyzed. Five new types of dismountable joints are proposed. Experimental studies of concrete filled tubular elements have been carried out. It was determined that the most effective for compression was a joint with a steel coupling and for bending the most effective was a joint with longitudinal ribs. The numerical modeling algorithm is presented; results are verified using experimental tests. A method for constructing N-M boundary dependences for concrete filled tubular structures is proposed. Bearing capacity diagrams for concrete filled tubular elements and their joints have been constructed. The costs of the materials needed to perform the joint as the example of a real construction for similar loads are analyzed.
22 December 2022 in Collection of scientific works of the Ukrainian State University of Railway Transport
The article analyzes the design solutions for the outer walls of residential buildings built in 2020-2022 in a city that belongs to the II temperature zone of Ukraine. The outer walls of the monolithic reinforced concrete frame of the building are made of hollow brick 250 mm thick with a façade system of heat-insulating and finishing class A. A verification thermotechnical calculation of the outer wall was carried out, taking into account heat-conducting inclusions, the reduced heat transfer resistance of an opaque enclosing structure (wall) does not correspond to the minimum allowable value of heat transfer resistance of the corresponding structure according to DBN V.2.6 – 31:2016 for the II temperature zone. When taking into account the effect of air permeability on reducing the overall level of thermal protection of the fence, it was determined that the calculated reduced value of the resistance to heat transfer of the outer wall will be even lower due to the fact that the structure consists of light cellular materials with a significant breathability. External enclosing structures and internal, dividing rooms with a temperature difference of 4 ° C or more, have insufficient insulation thickness. When developing insulation measures, the effect of air filtration through wall structures made of lightweight materials is not taken into account. The requirements for the insulation of complex structural units of enclosing structures to prevent the formation of "cold bridges", for example, a balcony slab, are not met. Translucent structures, which occupy more than 50% of the facades, are the cheapest, their heat transfer resistance is less than the minimum allowable value. Based on the results of the analysis, the main measures to improve the energy efficiency of residential multi-storey buildings were identified to enable the installation of large windows in residential and public buildings in the climatic conditions of Ukraine.
Steel trapezoidal profiled sheeting (STPS) is widely used in the construction industry. It is often viewed not as a structural element but as a material with its own properties, similar to bricks or masonry blocks. Consequently, to determine the load-bearing capacity and deformability of STPS, engineers most often rely on tables developed at the request of manufacturers. In Europe, these tables are compiled according to the EN 1993-1-3 methodology. However, there is a notable lack of studies comparing the results of theoretical calculations and manufacturer-provided data with the outcomes of experimental tests on full-scale profiled sheeting samples. For this reason, the authors conducted a study of 12 full-scale specimens of second-generation trapezoidal sheeting. The samples were tested under a two-span scheme, with deflections measured at the midpoint of each span and settlement of the sheeting at the supports. The study found that half the specimens showed higher deformability in the elastic stage than predicted, with differences of 16% to 105% based on span length and sheet thickness. For 11 out of 12 tested specimens, the onset of plastic deformations occurred before the samples reached their theoretical load-bearing capacity. The main novelty is identifying differences between Eurocode calculations and experimental results, showing higher deflections and earlier plastic deformations in tests. These full-scale STPS results offer both scientific and practical value.
Ядерна безпека є одним з важливих питань для будь-якої країни. Умови повномасштабної війни в Україні різко загострили питання реальної захисної спроможності укриттів, які масово облаштовують у підвальних і цокольних приміщеннях без належної перевірки відповідності властивостям захисних споруд цивільного захисту, зокрема і протирадіаційних укриттів. Навіть наявні протирадіаційні укриття, споруджені ще в минулому столітті, потребують перегляду відповідності сучасним вимогам щодо несучої здатності та послаблення іонізуючого випромінювання. У статті на конкретному об’єкті показано, як системна оцінка дозволяє встановити фактичну відповідність / невідповідність підвального приміщення будівлі ознакам протирадіаційного укриття за ДБН В.2.2-5:2023. Методика оцінки охоплювала натурне обстеження, аналіз об’ємно-планувальних рішень й інженерних систем, перевірні розрахунки несучої здатності конструкцій, визначення коефіцієнта послаблення іонізуючого випромінювання. Результати засвідчили низку критичних невідповідностей: відсутність механічної вентиляції, захисних дверей та аварійних виходів; дефіцит площі основних приміщень, обов’язкових допоміжних приміщень і санітарно-гігієнічного обладнання; прокладання мереж без захисних футлярів. За розрахунками несуча здатність плит перекриття і стін є недостатньою на повне еквівалентне навантаження у 22 рази та 1,5 раза відповідно, а коефіцієнт послаблення випромінювання у сотні разів нижчий за нормативний; навіть після первинних заходів (влаштування тамбурів, закладення прорізів, зовнішнього обвалування стін) показник залишається у 8–20 разів меншим за вимогу. Практичне значення роботи полягає в демонстрації проведення перевірок, що дозволяє органам місцевого самоврядування, балансоутримувачам та проєктантам ідентифікувати «вузькі місця» типових підвальних укриттів й обґрунтовано планувати підсилення конструкцій і комплектацію інженерних систем до досягнення нормативної відповідності.
20 June 2018 in International Journal of Engineering & Technology
Stress-strain state and compressed flexible steel-reinforced concrete elements resistance capacity are investigated in the work. The experiment program is complied and steel reinforced concrete elements calculations methods are analyzed. Experimental sample design drawings are shown. Raw materials physical and mechanical properties are determined. Steel reinforced-concrete elements experimental and research studies have been carried out. Coboundary dependences N-M for steel reinforced concrete elements construction method is proposed. Resistance capacity diagrams for steel reinforced concrete elements are constructed depending on the element height and the applied eccentricity.