1 September 2023 in Nature Communications
Low-intensity transcranial ultrasound stimulation (TUS) is an emerging non-invasive technique for focally modulating human brain function. The mechanisms and neurochemical substrates underlying TUS neuromodulation in humans and how these relate to excitation and inhibition are still poorly understood. In 24 healthy controls, we separately stimulated two deep cortical regions and investigated the effects of theta-burst TUS, a protocol shown to increase corticospinal excitability, on the inhibitory neurotransmitter gamma-aminobutyric acid (GABA) and functional connectivity. We show that theta-burst TUS in humans selectively reduces GABA levels in the posterior cingulate, but not the dorsal anterior cingulate cortex. Functional connectivity increased following TUS in both regions. Our findings suggest that TUS changes overall excitability by reducing GABAergic inhibition and that changes in TUS-mediated neuroplasticity last at least 50 mins after stimulation. The difference in TUS effects on the posterior and anterior cingulate could suggest state- or location-dependency of the TUS effect—both mechanisms increasingly recognized to influence the brain’s response to neuromodulation.
1 March 2017 in Physics in Medicine & Biology
High intensity transcranial focused ultrasound is an FDA approved treatment for essential tremor, while low-intensity applications such as neurostimulation and opening the blood brain barrier are under active research. Simulations of transcranial ultrasound propagation are used both for focusing through the skull, and predicting intracranial fields. Maps of the skull acoustic properties are necessary for accurate simulations, and can be derived from medical images using a variety of methods. The skull maps range from segmented, homogeneous models, to fully heterogeneous models derived from medical image intensity. In the present work, the impact of uncertainties in the skull properties is examined using a model of transcranial propagation from a single element focused transducer. The impact of changes in bone layer geometry and the sound speed, density, and acoustic absorption values is quantified through a numerical sensitivity analysis. Sound speed is shown to be the most influential acoustic property, and must be defined with less than 4% error to obtain acceptable accuracy in simulated focus pressure, position, and volume. Changes in the skull thickness of as little as 0.1 mm can cause an error in peak intracranial pressure of greater than 5%, while smoothing with a 1 kernel to imitate the effect of obtaining skull maps from low resolution images causes an increase of over 50% in peak pressure. The numerical results are confirmed experimentally through comparison with sonications made through 3D printed and resin cast skull bone phantoms.
16 September 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Models of ultrasound propagation in biologically relevant media have applications in planning and verification of ultrasound therapies and computational dosimetry. To be effective, the models must be able to accurately predict both the spatial distribution and amplitude of the acoustic pressure. This requires that the models are validated in absolute terms, which for arbitrarily heterogeneous media should be performed by comparison with measurements of the acoustic field. In this study, simulations performed using the open-source k-Wave acoustics toolbox, with a measurement-based source definition, were quantitatively validated against measurements of acoustic pressure in water and layered absorbing fluid media. In water, the measured and simulated spatial peak pressures agreed to within 3% under linear conditions and 7% under non-linear conditions. After propagation through a planar or wedge shaped glycerol-filled phantom, the difference in spatial peak pressure was 8.5% and 10.7%, respectively. These differences are within or close to the expected uncertainty of the acoustic pressure measurement. The -6 dB width and length of the focus agreed to within 4% in all cases, and the focal positions were within 0.7 mm for the planar phantom and 1.2 mm for the wedge shaped phantom. These results demonstrate that when the acoustic medium properties and geometry are well known, accurate quantitative predictions of the acoustic field can be made using k-Wave.
5 September 2025 in Nature Communications
We introduce an advanced transcranial ultrasound stimulation (TUS) system for precise deep brain neuromodulation, featuring a 256-element helmet-shaped transducer array (555 kHz), stereotactic positioning, individualised planning, and real-time fMRI monitoring. Experiments demonstrated selective modulation of the lateral geniculate nucleus (LGN) and connected visual cortex regions. Participants showed significantly increased visual cortex activity during concurrent TUS and visual stimulation, with high cross-individual reproducibility. A theta-burst TUS protocol produced robust neuromodulatory effects, decreasing visual cortex activity for at least 40 min post-stimulation. Control experiments confirmed these effects were specific to the targeted LGN. Our findings reveal this system’s potential to non-invasively modulate deep brain circuits with unprecedented precision and specificity, offering new avenues for studying brain function and developing targeted therapies for neurological and psychiatric disorders, with transformative potential for both research and clinical applications.
1 September 2021 in Brain Stimulation
16 August 2016 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Accurately representing the behavior of acoustic sources is an important part of ultrasound simulation. This is particularly challenging in ultrasound therapy where multielement arrays are often used. Typically, sources are defined as a boundary condition over a 2-D plane within the computational model. However, this approach can become difficult to apply to arrays with multiple elements distributed over a nonplanar surface. In this paper, a grid-based discrete source model for single- and multielement bowl-shaped transducers is developed to model the source geometry explicitly within a regular Cartesian grid. For each element, the source model is defined as a symmetric, simply connected surface with a single grid point thickness. Simulations using the source model with the open-source k-Wave toolbox are validated using the Rayleigh integral, O'Neil solution, and experimental measurements of a focused bowl transducer under both quasi-continuous wave and pulsed excitations. Close agreement is shown between the discrete bowl model and the axial pressure predicted by the O'Neil solution for a uniform curved radiator, even at very low grid resolutions. Excellent agreement is also shown between the discrete bowl model and experimental measurements. To accurately reproduce the near-field pressure measured experimentally, it is necessary to derive the drive signal at each grid point of the bowl model directly using holography. However, good agreement is also obtained in the focal region using uniformly radiating monopole sources distributed over the bowl surface. This allows the response of multielement transducers to be modeled, even where measurement of an input plane is not possible.