Yan To Ling

Ms. Yan To Ling

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2016 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
EMEleanor Martin
Eleanor Martin
YLYan To Ling
Yan To Ling
BTBradley E. Treeby
Bradley E. Treeby
Accurately representing the behavior of acoustic sources is an important part of ultrasound simulation. This is particularly challenging in ultrasound therapy where multielement arrays are often used. Typically, sources are defined as a boundary condition over a 2-D plane within the computational model. However, this approach can become difficult to apply to arrays with multiple elements distributed over a nonplanar surface. In this paper, a grid-based discrete source model for single- and multielement bowl-shaped transducers is developed to model the source geometry explicitly within a regular Cartesian grid. For each element, the source model is defined as a symmetric, simply connected surface with a single grid point thickness. Simulations using the source model with the open-source k-Wave toolbox are validated using the Rayleigh integral, O'Neil solution, and experimental measurements of a focused bowl transducer under both quasi-continuous wave and pulsed excitations. Close agreement is shown between the discrete bowl model and the axial pressure predicted by the O'Neil solution for a uniform curved radiator, even at very low grid resolutions. Excellent agreement is also shown between the discrete bowl model and experimental measurements. To accurately reproduce the near-field pressure measured experimentally, it is necessary to derive the drive signal at each grid point of the bowl model directly using holography. However, good agreement is also obtained in the focal region using uniformly radiating monopole sources distributed over the bowl surface. This allows the response of multielement transducers to be modeled, even where measurement of an input plane is not possible.

23 December 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
Niraj Singh TharuNiraj Singh Tharu
Niraj Singh Tharu
Monzurul AlamMonzurul Alam
Monzurul Alam
YLYan To Ling
Yan To Ling
Arnold Y.L. WongArnold Y.L. Wong
Arnold Y.L. Wong
YZY.P. Zheng
Y.P. Zheng
The aim of this study was to examine the effects of transcutaneous electrical spinal cord stimulation (TSCS) and conventional task-specific rehabilitation (TSR) on trunk control and sitting stability in people with chronic tetraplegia secondary to a spinal cord injury (SCI). Five individuals with complete cervical (C4–C7) cord injury participated in 24-week therapy that combined TSCS and TSR in the first 12 weeks, followed by TSR alone for another 12 weeks. The TSCS was delivered simultaneously at T11 and L1 spinal levels, at a frequency ranging from 20–30 Hz with 0.1–1.0 ms. pulse width biphasically. Although the neurological prognosis did not manifest after either treatment, the results show that there were significant increases in forward reach distance (10.3 ± 4.5 cm), right lateral reach distance (3.7 ± 1.8 cm), and left lateral reach distance (3.0 ± 0.9 cm) after the combinational treatment (TSCS+TSR). The stimulation also significantly improved the participants’ trunk control and function in sitting. Additionally, the trunk range of motion and the electromyographic response of the trunk muscles were significantly elevated after TSCS+TSR. The TSCS+TSR intervention improved independent trunk control with significantly increased static and dynamic sitting balance, which were maintained throughout the TSR period and the follow-up period, indicating long-term sustainable recovery.

18 June 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Ringo Tang-Long ZHURingo Tang-Long ZHU
Ringo Tang-Long ZHU
PLPei-Zhao Lyu
Pei-Zhao Lyu
SLShuai Li
Shuai Li
CTCheuk Ying Tong
Cheuk Ying Tong
YLYan To Ling
Yan To Ling
Christina Zong-Hao MaChristina Zong-Hao Ma
Christina Zong-Hao Ma
Making rapid and proper compensatory postural adjustments is vital to prevent falls and fall-related injuries. This study aimed to investigate how, especially how rapidly, the multiple lower-limb muscles and joints would respond to the unexpected standing balance perturbations. Unexpected waist-pull perturbations with small, medium and large magnitudes were delivered to twelve healthy young adults from the anterior, posterior, medial and lateral directions. Electromyographical (EMG) and mechanomyographical (MMG) responses of eight dominant-leg muscles (i.e., hip abductor/adductors, hip flexor/extensor, knee flexor/extensor, and ankle dorsiflexor/plantarflexors) together with the lower-limb joint angle, moment, and power data were recorded. The onset latencies, time to peak, peak values, and/or rate of change of these signals were analyzed. Statistical analysis revealed that: (1) agonist muscles resisting the delivered perturbation had faster activation than the antagonist muscles; (2) ankle muscles showed the largest rate of activation among eight muscles following both anteroposterior and mediolateral perturbations; (3) lower-limb joint moments that complied with the perturbation had faster increase; and (4) larger perturbation magnitude tended to evoke a faster response in muscle activities, but not necessarily in joint kinetics/kinematics. These findings provided insights regarding the underlying mechanism and lower-limb muscle activities to maintain reactive standing balance in healthy young adults.

20 May 2020 in Annals of Clinical and Translational Neurology
Verified
Journal Article
Open access
PDF file
Monzurul AlamMonzurul Alam
Monzurul Alam
YLYan To Ling
Yan To Ling
Arnold Y.L. WongArnold Y.L. Wong
Arnold Y.L. Wong
HZHui Zhong
Hui Zhong
VEVictor Reggie Edgerton
Victor Reggie Edgerton
YZY.P. Zheng
Y.P. Zheng
Objective: The objective of the current study was to investigate if a non‐invasive spinal cord neuromodulation modality could restore sensorimotor functions in a patient with chronic spinal cord injury (SCI).Methods: In this study, transcutaneous electrical stimulation (tES) to the spinal cord was utilized to restore sensorimotor functions in a chronic SCI patient who sustained a traumatic C7 cervical cord injury 21 years ago. At baseline, the patient had very limited volitional movement in her right leg, and her left leg was completely paralyzed. tES parameters were optimized in eight stimulation sessions before the treatment. The therapeutic stimulation involved biphasic tES, applied to T11 and L1 spinal levels during a 1‐hour standing and walking training, 2–4 times per week for 16 weeks.Results: Our pre‐treatment tests indicated that a shorter burst duration (100 µsec) was more effective than a longer burst duration of tES in improving functional movements. After 32 training sessions with tES, the patient regained significant left‐leg volitional movements (grade 0 to grade 10 according to the ISNCSCI scale). Right‐leg motor scores also increased from 17 to 21. The tES treatment also improved her pinprick sensation (from 73 to 79). Upon completion of the treatment (52 sessions), the patient’s standing ability noticeably improved. She could stabilize her knee to stand without any assistance. She could also squat while holding onto a walker.Interpretation: These promising results demonstrate beneficial effects of non‐invasive tES in regaining volitional control of plegic lower limbs in patients with chronic paralysis.

7 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Christina Zong-Hao MaChristina Zong-Hao Ma
Christina Zong-Hao Ma
YLYan To Ling
Yan To Ling
QSQueenie Tsung Kwan Shea
Queenie Tsung Kwan Shea
WLWang Like
Wang Like
XWXiao-Yun Wang
Xiao-Yun Wang
YZY.P. Zheng
Y.P. Zheng
Background: Motion capture and analyzing systems are essential for understanding locomotion. However, the existing devices are too cumbersome and can be used indoors only. A newly-developed wearable motion capture and measurement system with multiple sensors and ultrasound imaging was introduced in this study. Methods: In ten healthy participants, the changes in muscle area and activity of gastrocnemius, plantarflexion and dorsiflexion of right leg during walking were evaluated by the developed system and the Vicon system. The existence of significant changes in a gait cycle, comparison of the ankle kinetic data captured by the developed system and the Vicon system, and test-retest reliability (evaluated by the intraclass correlation coefficient, ICC) in each channel’s data captured by the developed system were examined. Results: Moderate to good test-retest reliability of various channels of the developed system (0.512 ≤ ICC ≤ 0.988, p < 0.05), significantly high correlation between the developed system and Vicon system in ankle joint angles (0.638R ≤ 0.707, p < 0.05), and significant changes in muscle activity of gastrocnemius during a gait cycle (p < 0.05) were found. Conclusion: A newly developed wearable motion capture and measurement system with ultrasound imaging that can accurately capture the motion of one leg was evaluated in this study, which paves the way towards real-time comprehensive evaluation of muscles and joint motions during different activities in both indoor and outdoor environments.

31 December 2019 in The Neuroscientist
Verified
Journal Article
Open access
PDF file
YLYan To Ling
Yan To Ling
Monzurul AlamMonzurul Alam
Monzurul Alam
YZY.P. Zheng
Y.P. Zheng
Paired associative stimulation (PAS) is a noninvasive neuromodulation method with rare cases of adverse effects for the patients with neurological injuries such as spinal cord injury (SCI). PAS is based on the principles of associative long-term potentiation and depression where the activation of presynaptic and postsynaptic neurons correlated in time is artificially induced. Statistically significant improvement in motor functions after applying PAS has been reported by several research groups. With further standardization of the technique, PAS could be an effective treatment for functional rehabilitation of SCI patients. In this review, we have summarized the methods and findings of PAS on SCI rehabilitation to facilitate the readers to understand the potentials and limitations of PAS for its future clinical use.