Lucile Alexandre

Lucile Alexandre

Auto-generated profile, based on publicly available information

Lucile Alexandre

Laboratoire NABI NAnomédecine, Biologie extracellulaire, Intégratome et Innovations, Université Paris Cité, CNRS UMR8175, INSERM U1334 75006 Paris, France

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2025 in ACS Nano
Verified
Journal Article
Closed access
LALucile Alexandre
Lucile Alexandre
DDDaniele D'Arrigo
Daniele D'Arrigo
NKNicolas Kuszla
Nicolas Kuszla
AAAndré Cronemberger Andrade
André Cronemberger Andrade
ASAmanda K. A. Silva
Amanda K. A. Silva
SMStéphanie Mangenot
Stéphanie Mangenot

8 June 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LALucile Alexandre
Lucile Alexandre
ABAmel Bendali
Amel Bendali
IPIago Pereiro
Iago Pereiro
MAMadad Azimani
Madad Azimani
SDSimon Dumas
Simon Dumas
SDStéphanie Descroix
Stéphanie Descroix
The cytokine interleukin 6 (IL-6) is involved in the pathogenesis of different inflammatory diseases, including cancer, and its monitoring could help diagnosis, prognosis of relapse-free survival and recurrence. Here, we report an innovative microfluidic approach that uses the fluidization of magnetic beads to specifically extract, preconcentrate and fluorescently detect IL-6 directly on-chip. We assess how the physical properties of the beads can be tuned to improve assay performance by enhancing mass transport, reduce non-specific binding and multiply the detection signal threefold by transitioning between packed and fluidization states. With the integration of a full ELISA protocol in a single microfluidic chamber, we show a twofold reduction in LOD compared to conventional methods along with a large dynamic range (10 pg/mL to 2 ng/mL). We additionally demonstrate its application to IL-6 detection in undiluted serum samples.

30 May 2022 in Talanta
Verified
Journal Article
Open access
MMMarco Morani
Marco Morani
MTMyriam Taverna
Myriam Taverna
ZKZuzana Krupova
Zuzana Krupova
LALucile Alexandre
Lucile Alexandre
PDPierre Defrenaix
Pierre Defrenaix
TMThanh Duc Mai
Thanh Duc Mai
In this study, we present a novel microfluidic droplet-based strategy for high performance isolation of extracellular vesicles (EVs). For EVs capture and release, a magnetic bead-based approach without having recourse to any antibody was optimized in batch and then adapted to the microfluidic droplet system. This antibody-free capture approach relies on the presence of a water-excluding polymer, polyethylene glycol (PEG), to precipitate EVs on the surface of negatively charged magnetic beads. We significantly improved the reproducibility of EV recovery and avoided positive false bias by including a washing step and optimizing the protocol. Well-characterized EV standards derived from pre-purified bovine milk were used for EVs isolation performance evaluation. An EVs recovery of up to 25% estimated with nanoparticle tracking analysis (NTA) was achieved for this batchwise PEG-based approach. The confirmation of isolated EVs identity was also made with our recently developed method using capillary electrophoresis (CE) coupled with laser-induced fluorescent (LIF) detection. In parallel, a purpose-made droplet platform working with magnetic tweezers was developed for translation of this PEG-based method into a droplet microfluidic protocol to further improve the performance in terms of EVs capture efficiency and high throughput. The droplet-based protocol offers a significant improvement of recovery rate (up to 50%) while reducing sample and reagent volumes (by more than 10 folds) and operation time (by 3 folds) compared to the batch-wise mode.

4 March 2024 in ACS Sensors
Verified
Journal Article
Open access
LALucile Alexandre
Lucile Alexandre
MSMolly L. Shen
Molly L. Shen
LALorenna Oliveira Fernandes de Araujo
Lorenna Oliveira Fernandes de Araujo
JRJohan Renault
Johan Renault
PDPhilippe DeCorwin-Martin
Philippe DeCorwin-Martin
DJDavid Juncker
David Juncker
Extracellular vesicles (EVs) are nanometric lipid vesicles that shuttle cargo between cells. Their analysis could shed light on health and disease conditions, but EVs must first be preserved, extracted, and often preconcentrated. Here we first compare plasma preservation agents, and second, using both plasma and cell supernatant, four EV extraction methods, including (i) ultracentrifugation (UC), (ii) size-exclusion chromatography (SEC), (iii) centrifugal filtration (LoDF), and (iv) accousto-sorting (AcS). We benchmarked them by characterizing the integrity, size distribution, concentration, purity, and expression profiles for nine proteins of EVs, as well as the overall throughput, time-to-result, and cost. We found that the difference between ethylenediaminetetraacetic acid (EDTA) and citrate anticoagulants varies with the extraction method. In our hands, ultracentrifugation produced a high yield of EVs with low contamination; SEC is low-cost, fast, and easy to implement, but the purity of EVs is lower; LoDF and AcS are both compatible with process automation, small volume requirement, and rapid processing times. When using plasma, LoDF was susceptible to clogging and sample contamination, while AcS featured high purity but a lower yield of extraction. Analysis of protein profiles suggests that the extraction methods extract different subpopulations of EVs. Our study highlights the strengths and weaknesses of sample preprocessing methods, and the variability in concentration, purity, and EV expression profiles of the extracted EVs. Preanalytical parameters such as collection or preprocessing protocols must be considered as part of the entire process in order to address EV diversity and their use as clinically actionable indicators.

6 September 2023 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
LALucile Alexandre
Lucile Alexandre
MAMonica Araya-Farias
Monica Araya-Farias
MNManh-Louis Nguyen
Manh-Louis Nguyen
NNNikoletta Naoumi
Nikoletta Naoumi
GGGiacomo Gropplero
Giacomo Gropplero
SDStéphanie Descroix
Stéphanie Descroix
Liquid biopsy, in particular circulating tumor DNA (ctDNA) analysis, has paved the way for a new noninvasive approach to cancer diagnosis, treatment selection and follow-up. As a crucial step in the analysis, the extraction of the genetic material from a complex matrix needs to meet specific requirements such as high specificity and low loss of target. Here, we developed a new generation of microfluidic fluidized beds (FBs) that enable the efficient extraction and preconcentration of specific ctDNA sequences from human serum with flow rates up to 15 µL/min. We first demonstrated that implementation of a vibration system inducing flow rate fluctuations combined with a mixture of different bead sizes significantly enhanced bead homogeneity, thereby increasing capture efficiency. Taking advantage of this new generation of high-throughput magnetic FBs, we then developed a new method to selectively capture a double-stranded (dsDNA) BRAF mutated DNA sequence in complex matrices such as patient serum. Finally, as proof of concept, ligation chain reaction (LCR) assays were performed to specifically amplify a mutated BRAF sequence, allowing the detection of concentrations as low as 6 × 104 copies/µL of the mutated DNA sequence in serum.

10 February 2026 in Biomacromolecules
Verified
Journal Article
Open access
MCMengyuan Cao
Mengyuan Cao
FFFrançois Fay
François Fay
AHAdrouchan Hotier
Adrouchan Hotier
SDSéverine DOMENICHINI
Séverine DOMENICHINI
LALucile Alexandre
Lucile Alexandre
EFElias Fattal
Elias Fattal
Activated proinflammatory macrophages are associated with various inflammatory diseases, and due to their overexpression of the CD44 receptor, they may be targeted for therapy by hyaluronic acid (HA), its natural ligand. This study aimed to develop lipid nanoparticles (LNPs) functionalized with HA and stabilized with an optimized amount of poly(ethylene glycol) (PEG) for targeted mRNA delivery to activated macrophages. Using microfluidic mixing, LNPs were produced with either 1.5% PEG (LNP1.5%PEG) or 0.5% PEG (LNP0.5%PEG). HA-coated LNPs (HA-LNPs) were prepared by postinsertion of an HA-DPPE conjugate, and changes in size and zeta potential demonstrated a successful and efficient HA coating, which was quantified by spectrofluorimetry and nanoscale flow cytometry. In vitro studies showed that HA-LNP0.5%PEG exhibited better uptake in activated macrophages while maintaining mRNA transfection efficiency, whereas HA-LNP1.5%PEG did not improve its uptake, suggesting that excessive PEG can hinder targeting. Overall, HA-LNP0.5%PEG effectively delivered mRNA to activated macrophages with enhanced selectivity.