Christopher Decarlo

Christopher Decarlo

Auto-generated profile, based on publicly available information

Christopher Decarlo

US Aggregates, Indianapolis, IN

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2019 in Journal of Testing and Evaluation
Verified
Journal Article
Closed access
CDChristopher DeCarlo
Christopher DeCarlo
EDEshan Dave
Eshan Dave
JSJo Sias
Jo Sias
GAGordon Airey
Gordon Airey
RMRajib Mallick
Rajib Mallick
Asphalt materials experience substantial amounts of environmental damage throughout their lives as surface layers in pavements. One of the most prominent forms of environmental damage, moisture-induced damage, is caused by the weakening of internal bonds of the material because of the presence of moisture in the voids of asphalt mixtures and is a common problem for asphalt pavements in wet climates. Moisture-induced damage is typically accounted for during asphalt mixture design by conducting performance tests to ensure the material is not susceptible to severe damage from moisture, although many of these methods have seen mixed amounts of success historically. The main objective of this study is to evaluate the ability of multiple asphalt mixture moisture susceptibility tests to identify good and poor performing mixtures with respect to moisture-induced damage to replace current mix design testing requirements. Ten plant-produced hot mix asphalt materials with established good and poor field moisture performance were subjected to various moisture susceptibility test methods. The results from these procedures are assessed to determine which procedure is most effective and practical as a moisture susceptibility test for routine usage during asphalt mixture design for transportation agencies. Results from this study suggest that performance tests with stiffness-based measurements, such as dynamic modulus paired with moisture conditioning and the saturated aging tensile stiffness procedure, show better correlation to field performance than traditional test methods such as AASHTO T-283, Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage, and that the Hamburg wheel tracker test is the most effective and practical test method to reliably identify mixtures prone to experiencing moisture-induced damage.

1 September 2019 in Journal of Transportation Engineering, Part B: Pavements
Verified
Journal Article
Closed access
RMRajib B. Mallick
Rajib B. Mallick
NKNivedya Madankara Kottayi
Nivedya Madankara Kottayi
RVRam Kumar Veeraragavan
Ram Kumar Veeraragavan
EDEshan Dave
Eshan Dave
CDChristopher DeCarlo
Christopher DeCarlo
JSJo Sias
Jo Sias
The objectives of this study were to determine a suitable set of tests to use with a moisture-conditioning process and to develop a machine learning model to predict the moisture susceptibility of hot mix asphalt. Laboratory-compacted samples of 17 plant-produced mixes with known field performance were subjected to mechanical tests before and after moisture conditioning with the moisture-induced stress tester (MiST). Statistical analysis showed that seismic modulus and indirect tensile strength were effective in distinguishing the poor-performing mixes from the well-performing mixes. Principal component analysis was conducted on the test data, and a reduced set of dimensions that were capable of explaining much of the variance in the data was identified. The significant test properties were used to develop machine learning models with two supervised classification approaches. The k -nearest neighbor model was found to be very accurate in differentiating the mixes. The use of MiST conditioning, the specified physical tests, and machine learning methods is recommended for the identification of moisture-susceptible hot-mix asphalt.

23 June 2022 in Transportation Research Record: Journal of the Transportation Research Board
Verified
Journal Article
Closed access
MSMahmoud Samara
Mahmoud Samara
DODaniel Offenbacker
Daniel Offenbacker
YMYusuf Mehta
Yusuf Mehta
AAAyman Ali
Ayman Ali
MEMohamed Elshaer
Mohamed Elshaer
CDChristopher Decarlo
Christopher Decarlo
Rejuvenators are used in the asphalt industry to improve the performance and durability of aged binders and facilitate the use of recycled asphalt materials. The purpose of this study was to evaluate the impact of rejuvenator type and dose on the laboratory performance of asphalt binders. For this study, recycled asphalt pavement (RAP) and extracted RAP binder were obtained from an airfield reconstruction project located in Atlantic City, NJ. One petroleum-based (aromatic extract) and three organic-based (corn oil, tall oil, and modified vegetable oil) rejuvenators were evaluated in this study. Each rejuvenator was used at two different rejuvenator doses (6% and 12% by total RAP binder weight) and was aged at three different levels. Performance grade testing, frequency sweep tests, critical temperature differential (ΔTc ), and Fourier transform infrared spectroscopy (FTIR) tests were conducted. Results showed that the use of rejuvenators lowered the high and low performance grade of extracted RAP binders, in particular organic-based rejuvenators had a greater impact on the performance grade. ΔT c was also improved through the use of rejuvenators. In fact, the extracted RAP binder exceeded the high severity ΔTc threshold (−5°C), whereas the rejuvenated RAP binders improved ΔT c to values greater than the low severity threshold (−2.5°C). Similar findings were observed from the Glover-Rowe parameter as well, in which rejuvenated RAP binders improved the cracking resistance of the extracted RAP binder. When assessing the aging susceptibility, modified vegetable oil and corn oil rejuvenators showed the smallest change in performance between aging levels.

4 May 2023 in Transportation Research Record: Journal of the Transportation Research Board
Verified
Journal Article
Closed access
AMAshith Marath
Ashith Marath
ASAhmed Saidi
Ahmed Saidi
AAAyman Ali
Ayman Ali
YMYusuf Mehta
Yusuf Mehta
MEMohamed Elshaer
Mohamed Elshaer
CDChristopher Decarlo
Christopher Decarlo
This study aims to evaluate the electrical conductivity and mechanical performance of electrically conductive asphalt (ECA) mixtures to be used in cold regions for deicing applications. In this study, the ECA mixtures were prepared using a combination of two conductive additives (graphite and carbon fibers), three lengths of carbon fibers (3 mm, 6 mm, and 24 mm), and gneiss aggregates with two nominal maximum aggregate sizes (NMAS) (4.75 mm and 9.5 mm). For each mixture, different dosages of conductive additives were selected: (a) 5%, 10%, 15%, and 30% by asphalt volume for graphite, and (b) 0%, 1%, and 2% by asphalt volume for carbon fibers. A multimeter was then used to assess the electrical resistivity of each ECA mixture, while asphalt pavement analyzer and indirect tension cracking tests were performed to evaluate ECA rutting susceptibility and cracking resistance, respectively. The durability of ECA mixtures was also determined at intermediate temperatures using the Cantabro loss test to assess their integrity when carbon fibers are added. Results showed that aggregates with NMAS of 4.75 mm and carbon fibers with a length of 6 mm presented the most improvement in ECA mechanical performance. In addition, ECA mixtures with 30% graphite presented similar electrical resistivity to those prepared with 15% graphite and 2% carbon fiber (6 mm). In respect of mechanical performance, the addition of 2% carbon fiber improved the resistance of ECA mixtures at 15% graphite to both cracking and durability by at least 20%.

17 August 2023 in Transportation Research Record: Journal of the Transportation Research Board
Verified
Journal Article
Closed access
AMAshith Marath
Ashith Marath
AAAyman Ali
Ayman Ali
ASAhmed Saidi
Ahmed Saidi
YMYusuf Mehta
Yusuf Mehta
MEMohamed Elshaer
Mohamed Elshaer
CDChristopher Decarlo
Christopher Decarlo
Electrically heated pavements are an emerging technology for deicing applications in cold regions. Such pavements usually contain a conductive layer (asphalt or concrete) and electrodes to transmit electricity through the pavement, thus heating it. The goal of this study was to evaluate the heating ability of electrically conductive pavement structures under cold weather conditions. To achieve this goal, three full-scale pavement strips were constructed at Rowan University. Test strip I was a conventional pavement strip without any heating elements, whereas test strips II and III had conductive asphalt layer sandwiched between base and asphalt surface courses. The conductive layer in test strip II consisted of a mixture of asphalt binder and conductive fibers, whereas test strip III contained a modified high-performance thin overlay (HPTO) mixture with graphite and carbon fibers. To provide electric potential across the conductive layers, steel electrodes with different spacings (6 in. and 12 in.) were installed at the bottom of the conductive layers of test strips II and III, and connected to a 24V AC power source. Electrical data showed that test strip II had a power consumption of 19.75 W/ft 2 , which was nearly four times higher than test strip III. Thermal data showed that the surface temperature of test strip III with 6 in. electrode spacing increased above freezing point with nearly 50% less power consumption than test strip II. Further, electrodes with 6 in. spacing resulted in the highest increase of pavement surface temperature, which was 3°F higher than electrodes with 12 in. spacing.

30 March 2023 in Transportation Research Record: Journal of the Transportation Research Board
Verified
Journal Article
Closed access
MHMahdi Habibpour
Mahdi Habibpour
AAAyman Ali
Ayman Ali
DODaniel Offenbacker
Daniel Offenbacker
YMYusuf Mehta
Yusuf Mehta
MEMohamed Elshaer
Mohamed Elshaer
CDChristopher Decarlo
Christopher Decarlo
This study aims to evaluate the potential of using geosynthetics to reinforce flexible pavements and improve their resistance to reflective cracking. To achieve the goals, three full-scale test strips (control, geogrid, and geotextile) were constructed at Rowan University, each being 30 ft long by 15 ft wide. The pavement structure of each test strip included two hot mix asphalt (HMA) layers with a total thickness of 3.0 in., and five intentional cracks (with widths of 0.2 in.) were introduced to the first HMA layer. After sealing the cracks and applying the tack coat layer, the geosynthetic interlayer was added, and the top HMA layer was constructed. Asphalt strain gauges and thermocouples were embedded in each section to measure critical strains. All sections were also loaded using a heavy vehicle simulator (HVS) with dual-tire configurations while the temperature around the test strips was maintained at 50°F. In addition, each test strip’s deflection and rutting were measured before and after HVS loading using a heavy weight deflectometer and a laser profiler, respectively. The HVS loading results found that the geogrid-reinforced test strip had a better strain response than the geotextile-reinforced layer, and the geotextile-reinforced layer showed slightly higher bonding (lower delamination). It is noted that the results of this study are in line with a former laboratory study with respect to crack reflection and delamination. Rut profiler data recorded a 25% reduction in rut depth for reinforced sections compared to the control. Moreover, the geosynthetic interlayer was able to mitigate reflective cracking propagation. Both interlayers improved fatigue performance.