Yikai Sun

Yikai Sun

Auto-generated profile, based on publicly available information

Yikai Sun

State Grid Zhejiang Economy Research Institute, Hangzhou, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
HHHanyan Huang
Hanyan Huang
MZMing Zhou
Ming Zhou
SZShiyi Zhang
Shiyi Zhang
LZLijun Zhang
Lijun Zhang
GLGengyin Li
Gengyin Li
YSYikai Sun
Yikai Sun
Due to inherent uncertainty and volatility, large-scale wind power integration brings new challenges to the flexible operation of power systems. It calls for more flexibility not only from the generation side but also from the grid side, especially the hybrid HVAC/HVDC transmission grid. This paper proposes to exploit potential flexibility by controlling power flows through HVDC by the merits of its flexible regulation capability, as well as HVAC transmission switching (TS). To synergistically schedule them with generator units, a security-constrained economic dispatch (SCED) model for wind integrated hybrid AC/DC power system is presented to realize the co-optimization of generation and TS. Wherein, multiple uncertainties (wind power fluctuation and generator failure) are considered, and the linear power flow model of the DC grid is adopted. Then the model is transformed into a two-stage (normal state optimization and corrective dispatch verification) robust optimization (RO) model for iterative solution by the aid of the column-and-constraint generation (C&CG) algorithm. Case studies on the modified IEEE 14-bus and IEEE 118-bus systems show that TS can assist HVDC to optimize power flow distribution and provide more flexibility, meanwhile optimizing HVDC transmission power and TS can greatly reduce the operating cost of the whole system.

29 April 2018 in Energies
Verified
Journal Article
Open access
PDF file
QYQingyou Yan
Qingyou Yan
YWYaxian Wang
Yaxian Wang
Tomas BalezentisTomas Balezentis
Tomas Balezentis
YSYikai Sun
Yikai Sun
Dalia StreimikieneDalia Streimikiene
Dalia Streimikiene
China’s electricity sector mainly relies on coal-fired thermal generation, thus resulting that nearly 50% of China’s total CO2 emissions coming from the electricity sector. This study focuses on the provincial CO2 emissions from China’s thermal electricity generation. Methodologically, Index Decomposition Analysis (IDA), facilitated by the Shapley Index, is applied to discover the driving factors behind CO2 emission changes at the provincial level. In addition, the Slack-based Model (SBM) is used to identify which provincial power grids should be allocated with a higher (lower) CO2 reduction burden. The IDA results indicate that economic activity pushed the CO2 emissions up in all 30 provincial power grids, excluding Beijing and Shanghai; the carbon factor contributed to a decrease in the CO2 emissions in all 30 provincial power grids, with the exception of Jilin, Guangdong, and Ningxia; though the effect of energy intensity varied across the 30 provinces, it played a significant role in the mitigation of CO2 emissions in Beijing, Heilongjiang, Liaoning, Jilin, Shanghai, Anhui, and Sichuan. According to the SBM results, the lowest carbon shadow prices are observed in Yunnan, Shanghai, Inner Mongolia, Jilin, Qinghai, Guizhou, Anhui, and Ningxia. These provincial power grids, thus, should face higher mitigation targets for CO2 emissions from thermal electricity generation.

18 March 2020 in IEEE Access
Verified
Journal Article
Open access
AXAncheng XUE
Ancheng XUE
JZJiahuan Zhang
Jiahuan Zhang
LZLijun Zhang
Lijun Zhang
YSYikai Sun
Yikai Sun
JCJiehao Cui
Jiehao Cui
JWJiawei Wang
Jiawei Wang
For the power system interconnected with the large-scale offshore wind power through VSC-HVDC, such as SZ power grid, it may be engaged with transient frequency stability and lack of related control due to the randomness, fluctuation and intermittence of the wind. This paper proposes a transient frequency control strategy for the power system interconnected with offshore wind power through VSC-HVDC based on sensitivity. Firstly, the structure of SZ power grid and the calculation method of transient frequency stability index are introduced, and the transient frequency problems existing in SZ power grid are explored. Secondly, the mathematical formulation for the transient frequency control is described, including the objective function and the constraints. Furthermore, a transient frequency emergency control strategy based on special sequence and the sensitivities is proposed, which includes thermal units regulation, wind power regulation, DC modulation and load shedding. Finally, the effectiveness of the proposed control strategy is verified by simulation in SZ power grid.

13 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
CYChutian Yu
Chutian Yu
XLXinyi Lai
Xinyi Lai
FCFei Chen
Fei Chen
CJChenwei Jiang
Chenwei Jiang
YSYikai Sun
Yikai Sun
Donglian QiDonglian Qi
Donglian Qi
With the target of carbon peaking and carbon neutrality, renewable energy generation (REG) develops rapidly. The increasing penetration of REG brings along the problems of fluctuation in power flow and the possible abandonment of wind and photovoltaics (PV) generation. In this context, the so-called integrated energy system (IES) becomes a promising solution to the accommodation of REG thanks to energy storage systems and coupling devices inside. In this paper, the optimal operation model of an IES is first presented, with the schemes of green certificate trading and carbon emission right trading included to provide economic incentives for accommodating REG. Next, in order to address the problem of uncertainty in REG, the devices in the IES are divided into three types based on regulation flexibility, and a multi-time period optimal dispatching scheme is proposed, including day-ahead optimal scheduling, rolling optimal dispatching, and real-time control strategy. Finally, it is demonstrated by simulation results of a numerical example that the proposed method not only promotes the accommodation capability for REG but can also cope well with contingencies.

1 December 2019
Verified
Conference Paper
Closed access
YSYikai Sun
Yikai Sun
LZLijun Zhang
Lijun Zhang
BZBo Zhang
Bo Zhang
Jing ZhangJing Zhang
Jing Zhang
XZXizhu Zhagn
Xizhu Zhagn
AXAncheng XUE
Ancheng XUE
After the ZS five-terminal flexible DC transmission demonstration project in Zhejiang Province put into operation, the stability characteristics of ZS Power Grid have been changed. Based on the ZS equivalent grid with flexible DC connection for offshore wind power, the maximum output of offshore wind power considering voltage stability is analyzed in this paper. The details are as follows: Firstly, based on the conventional system equivalent method, the ZS Power Grid is equivalent to a small system with the same grid structure, thus simplifying the research object. Secondly, the branch voltage stability indexes are briefly introduced, and their adaptabilities to the equivalent grid are verified. Finally, based on the branch voltage stability index, the maximum output of the wind farm considering voltage stability is given.

19 June 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
ZLZhang Lijun
Zhang Lijun
ZYZhong Yujun
Zhong Yujun
CRChen Rui
Chen Rui
SYSun Yikai
Sun Yikai
ZJZhang Jing
Zhang Jing
JKJia Ke
Jia Ke
When offshore wind power is transmitted to ac grid through MMC-HVDC, the current and voltage will be quite different from those in traditional ac grid during grid side fault. This paper sets up an offshore wind farm integration system via MMC-HVDC and designs control strategies for each unit in the system. The fault ride through strategy of the system is proposed and its effectiveness has been verified. Thus, the AC bus voltage on wind farm side will stay stable during AC side fault. Once the chopper resistance is set properly, the output power and current of the wind farm can basically remain unchanged, which can successfully achieve fault isolation. The simulation results based on PSCAD have verified the theoretical analysis.