Lijun Zhang

Lijun Zhang

Auto-generated profile, based on publicly available information

Lijun Zhang

State Grid Zhejiang Economy Research Institute, Hangzhou, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2020 in IEEE Access
Verified
Journal Article
Open access
AXAncheng XUE
Ancheng XUE
JZJiahuan Zhang
Jiahuan Zhang
LZLijun Zhang
Lijun Zhang
YSYikai Sun
Yikai Sun
JCJiehao Cui
Jiehao Cui
JWJiawei Wang
Jiawei Wang
For the power system interconnected with the large-scale offshore wind power through VSC-HVDC, such as SZ power grid, it may be engaged with transient frequency stability and lack of related control due to the randomness, fluctuation and intermittence of the wind. This paper proposes a transient frequency control strategy for the power system interconnected with offshore wind power through VSC-HVDC based on sensitivity. Firstly, the structure of SZ power grid and the calculation method of transient frequency stability index are introduced, and the transient frequency problems existing in SZ power grid are explored. Secondly, the mathematical formulation for the transient frequency control is described, including the objective function and the constraints. Furthermore, a transient frequency emergency control strategy based on special sequence and the sensitivities is proposed, which includes thermal units regulation, wind power regulation, DC modulation and load shedding. Finally, the effectiveness of the proposed control strategy is verified by simulation in SZ power grid.

1 December 2019
Verified
Conference Paper
Closed access
YSYikai Sun
Yikai Sun
LZLijun Zhang
Lijun Zhang
BZBo Zhang
Bo Zhang
Jing ZhangJing Zhang
Jing Zhang
XZXizhu Zhagn
Xizhu Zhagn
AXAncheng XUE
Ancheng XUE
After the ZS five-terminal flexible DC transmission demonstration project in Zhejiang Province put into operation, the stability characteristics of ZS Power Grid have been changed. Based on the ZS equivalent grid with flexible DC connection for offshore wind power, the maximum output of offshore wind power considering voltage stability is analyzed in this paper. The details are as follows: Firstly, based on the conventional system equivalent method, the ZS Power Grid is equivalent to a small system with the same grid structure, thus simplifying the research object. Secondly, the branch voltage stability indexes are briefly introduced, and their adaptabilities to the equivalent grid are verified. Finally, based on the branch voltage stability index, the maximum output of the wind farm considering voltage stability is given.