Iryna Peftieva

Iryna Peftieva

Auto-generated profile, based on publicly available information

Iryna Peftieva


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2022 in Ventilation, Illumination and Heat Gas Supply
Verified
Journal Article
Open access
PDF file
YCY Chоvniuk
Y Chоvniuk
AMAnna Moskvitina
Anna Moskvitina
IPI. Peftieva
I. Peftieva
Акумулятори великої теплової ємності організовуються у природному ґрунтовому масиві впорядкованого сукупністю (“кущем”) вертикальних/горизонтальних теплообмінників, розміщених або у бурових свердловинах, або всередині циліндричних порожнин бетонного масиву у трубах. У результаті акумулювання створюється основна область накопиченої теплоти, яка обмежена зовнішнім контуром “куща”, певного об’єму й з певною температурою, а також буферна підобласть деякого об’єму, яка дотикається до основної і є результатом теплової взаємодії об’єму основної області з оточуючим ґрунтовим масивом, який має постійну температуру. Найменші розміри буферної підобласті будуть у випадку рівномірного по основному об’єму розподілу температури. Розміри буферної підобласті можна зменшувати, якщо створити верхній теплоізоляційний щит. При цьому габарити конструкції повинні бути оптимальними, тобто відповідати певному критерію, за якого відношення об’єму буферної підобласті до об’єму всього акумулятора теплоти є мінімальним. Наведений вдосконалений метод структурно-параметричної оптимізації ґрунтових акумуляторів теплоти в процесі аналізу їх функціонування. Визначені оптимальні співвідношення розмірів вказаних акумуляторів, які мають верхній теплоізоляційний щит ( чи без нього) , та розвинута методика , що дозволяє знаходити кількість теплообмінників, їх параметр і відстані між ними задля забезпечення мінімальних витрат на побудову акумулятора.

27 June 2022 in Ventilation, Illumination and Heat Gas Supply
Verified
Journal Article
Open access
PDF file
YFYu. Franchuk
Yu. Franchuk
IPI. Peftieva
I. Peftieva
У статті проведено дослідження термінів та вимог діючих нормативних документів що використовуються при газифікації різних об’єктів і при їх технічному обслуговуванні та ремонті. Поставлена задача вирішується шляхом порівняння нормативних документів. В роботі проаналізовано діючі нормативні документи та проведено аналіз термінів та визначень, властивих галузі газопостачання, таких як природний газ, якість газу, облік газу, система газопостачання, газонебезпечні роботи, технічні смуги, тиск, цистерна, балон та ін. Показано різність тлумачення одних і тих самих термінів в діючих нормативних документах, різні вимоги, доповнення деяких з них іншими. Стаття може стати у нагоді працівникам, що розслідують нещасні випадки або працюють у видобувній галузі, виконують газонебезпечні роботи, людям, що готуються до складання іспитів з охорони праці та їхньої подальшої роботи.

30 May 2022 in Urban development and spatial planning
Verified
Journal Article
Open access
PDF file
YCYuriy Chоvniuk
Yuriy Chоvniuk
PCPetro Cherednichenko
Petro Cherednichenko
AMAnna Moskvitina
Anna Moskvitina
IPIryna Peftieva
Iryna Peftieva
Accumulators of high thermal capacity are organized in a natural soil mass ordered by a set ("bush") of vertical/horizontal heat exchangers, which are placed either in boreholes or inside cylindrical cavities of a concrete mass in pipes. As a result of accumulation, a main region of accumulated heat is created, which is limited by the outer contour of the "bush", of a certain volume and with a certain temperature, as well as a buffer sub-region of a certain volume, which touches the main one and is the result of thermal interaction of the volume of the main region with the surrounding soil mass, which has constant temperature. The smallest dimensions of the buffer subregion will be in the case of a uniform temperature distribution over the main volume. This is achieved by organizing the same heat load that falls on each heat exchanger, the same potential of the intermediate heat carrier and a small difference in its temperatures, respectively, at the inlet and outlet of each heat exchanger, and a number of other requirements. The dimensions of the buffer subregion can be reduced by creating an upper heat shield. This will lead to a reduction in the dimensions of the entire structure and there will be no need for thermal insulation of pipelines that supply and discharge the coolant in the middle of the heat accumulator. In this case, the dimensions of the structure must be optimal, i.e. meet a certain criterion, in which the ratio of the volume of the buffer subregion to the volume of the entire heat accumulator is minimal. However, the optimization of the heat storage process in the presence of an upper heat-insulating shield, provided that the heat accumulator itself is located in a concrete building, has not been considered in the literature. Solutions to problems are presented that determine the optimal ratios of the sizes of ground heat accumulators placed in concrete casings and limited from above by a heat-insulating shield, and a method for finding the number of heat exchangers, their parameters and distances between them, which ensures minimal costs for the construction of the heat accumulator itself.

1 March 2021 in Urban development and spatial planning
Verified
Journal Article
Open access
PDF file
YCYuriy Chоvniuk
Yuriy Chоvniuk
PCPetro Cherednichenko
Petro Cherednichenko
AMAnna Moskvitina
Anna Moskvitina
IPIryna Peftieva
Iryna Peftieva
ЮЧЮрій Човнюк
Юрій Човнюк
ІПІрина Пефтєва
Ірина Пефтєва
With the signing of the Association Agreement with the EU, Ukraine took a number of obligations to reduce primary energy costs, incl. and in heating, ventilation, air conditioning systems and reduce the energy consumption of production. Along with this, the problem of thermal pollution of the environment, caused by an increase in emissions of greenhouse gases and pollutants into the atmospheric air with exhaust air, also requires a solution. All this requires the design of reliable and efficient energy storage systems, which will not only provide a stable energy supply to consumers, but also increase the energy utilization rate, as well as modernization of production processes and effective methods of cleaning exhaust air before it is released into the atmosphere. A method for studying vibration sources in pipeline elements of heat exchangers and structures transporting high-viscosity liquids, for example, in heat exchangers for charging and discharging heat accumulators, pipelines for transporting concrete solution and pipelines and structural elements for removing a mixture of dirt that is formed in scrubbers when cleaning dirty air with using water droplets from dust. To combat pipeline vibrations, proper design of pipeline systems is of great importance, which makes it possible to influence the hydrodynamic forces in pipelines and structural elements, which are the sources of these vibrations. It is shown that the hydrodynamic forces in pipelines are distributed over their entire inner surface, and in determining them it is useful to follow the path of a number of simplifications. It is useful to go from forces distributed over the surface to forces distributed along the axis of the pipeline by averaging the forces acting along the perimeter of each section. Since the forces along the axis of the pipeline are very unevenly distributed, it has been experimentally shown that the most intense are the hydrodynamic forces in the sections with abrupt changes in the geometry of the channel (the so-called local resistances), therefore, slightly curved sections of a constant cross-section should prevail, since the hydrodynamic forces in them are much less. The coefficients of similarity of the hydrodynamic force have been established, which depend only on the properties of the medium flowing through such channels. The same coefficients of similarity were found for the moments of forces. The spectra of force and characteristic frequencies are determined, where the intensity of the force is high.