25 November 2025 in Superconductivity
12 February 2018 in IEEE Transactions on Plasma Science
The test about simple central difference average (CDA) + MIK (Mik mutual inductance between ith and kth component) quench detection method implemented a total of about 100 charging runs on EAST in the past two years, aiming at verifying this new method whether to apply it to ITER CS coils or not. This project is supported by the ITER Organization. To obtain this target, the whole instrumentation hardware have been developed and installed on EAST and used to generate experimental data. Considering the whole new CS coils connection configuration and the possible risk for EAST device, the typical achievement is to accomplish successfully plasma scenarios (the longest shot of plasma current around 250 kA and pulse 3 s) by using a simple CDA + MIK quench detection method on EAST for the first time. Moreover, the numerical quench detection model has been designed, and the numerical signals are in good agreement with experimental data. Recent experimental results showed that CDA + MIK technology is applicable to the ITER CS coils as a backup method but the sensitivity of this system should be improved greatly in order to meet experiment requirements for ITER operation in the future. This paper introduces the test program, typical achieved operation, and the results of preliminary analysis.
27 November 2024 in IEEE Transactions on Applied Superconductivity
The central solenoid model coil (CSMC) is a preliminary research project for the China Fusion Engineering Test Reactor. Its goal is to design and manufacture superconducting model coils while gaining experience to address technical challenges in their design and construction. The CSMC aims for a maximum operating current of 47.65 kA, a maximum magnetic field of 12 T, and a rapid magnetic field change rate of 5 T/s. During operation, the superconducting magnets must withstand high voltage, which could lead to insulation damage. If the device is not stopped in time to repair the insulation, the magnet will lose its superconducting state and be damaged. Therefore, a reliable online insulation monitoring system is essential for early detection of insulation issues, preventing further damage from high voltage. This article uses the partial discharge method as the method of online insulation monitoring and uses the high-frequency current method to realize partial discharge detection. The hardware and software of the insulation monitoring system are designed and developed, respectively. At the same time, a series of experiments is carried out to extract the partial discharge signal characteristics of the superconducting magnet device as theoretical support. The effectiveness of this system has been verified in the CSMC Paschen test.
19 September 2023 in IEEE Transactions on Applied Superconductivity
High-Temperature Superconducting (HTS) Current Leads (CL) made of Bi-2223 superconducting tapes in Experimental and Advanced Superconducting Tokamak (EAST) are connected with the superconducting magnets and power supplies. The quench detection systems consist of primary (resistive voltage-based) and backup (temperature-based) detection systems; due to the required fast response time, the quench detection system for the EAST HTSCL relies primarily on direct voltage measurement. The traditional temperature and voltage detection methods have two main defects. Firstly, to prevent the temperature sensor from high-voltage breakdown, it has to be installed in the rear section of the insulators, leading to its sensitivity decreasing significantly. Secondly, because the average zone propagation velocity of HTS is around 1/100∼1/1000 of Low-Temperature Superconducting (LTS) materials, the small resistive voltage during quench is very difficult to detect. Distributed Optical Fibers Quench Detection (DOFQD) based on Raleigh Scattering (RS) can be a solution, which adopts the special communication glass fiber as the sensor. It can continuously monitor temperature changes (0.5 K to 2 K) at intervals of 5 mm. At the same time, the method has the advantages of high-voltage resistance and immunity from electromagnetic interference. But the biggest drawback of this method is that the Optical Fiber (OF) sensor is very brittle in the transverse direction resulting in complicated installation. Recently, the OF sensor has been directly laid inside the insulation layer of the HTSCL and led out of the vessel successfully. Meanwhile, the Parsons discharge test, the thermal shock test, and the vacuum leakage rate test can come up with the technical requirements. The power-on test was shown that DOFQD could detect a quench ahead of voltage measurement when the HTSCL was soaked in the 77 K liquid nitrogen. The next plan is to apply this quench detection method in the EAST HTSCL.
10 September 2025 in IEEE Transactions on Applied Superconductivity
In the next generation of fusion devices, the central solenoid (CS) coil needs to withstand large alternating currents and rapidly changing magnetic fields to achieve plasma breakdown, configuration formation and control. In this study, the quench behavior of a representative submodule (CS1U-LTS) is investigated under time-varying current and magnetic field conditions, where the local field ramp rate reaches approximately 2.5 T/s. This alternating operation mode significantly affects the stability of superconducting magnets. However, the current simulation of superconducting magnet quench is mostly based on steady-state current and steady-state background field, which is difficult to reflect the quench propagation characteristics of superconductors under alternating conditions as the current and magnetic field intensity and direction change. To ensure the safe operation of the CS coils under alternating conditions, this paper first analyzes the quench behavior in a reference case with constant peak current prior to an exponential discharge and determines the protection thresholds required to limit the hot spot temperature to below 150 K: 200 mV voltage threshold and 0.5 s time threshold. The quench response at the positive and negative current peaks during time-varying operation is further analyzed. The results show that under the same protection conditions, the maximum temperature of the CS1U-LTS coil in alternating operation still meets the design requirements. In addition, this paper compares the differences in quench propagation near the two peak points, revealing the impact of alternating operation on quench propagation behavior.
14 November 2024 in IEEE Transactions on Applied Superconductivity
A timely, accurate, and reliable quench detection system is important to the safe operation of superconducting magnets. For the superconducting magnets with rapidly changing current in the fusion device, the core challenge is to compensate the complex induced voltage to obtain the quench voltage signal. The EAST device has adopted the widely used Co-wound Wire (CWW) method for compensation. However, the CWW has experienced several failures during operation, and its installation within the insulation layer of the superconducting magnet makes repair extremely difficult. The pick-up coil is an alternative quench detection method that is relatively easy to install and repair. In this paper, a pick-up coil was designed, installed, and tested on the poloidal field (PF) 9 magnet of EAST. Experiments have shown that the pick-up coil can suppress 88% of the induced voltage. After the secondary compensation of improved Inductive Noise Realtime Calculation (MIK), the output signals meet the requirements of the quench detection system. Additionally, simulated quench events during the experiments confirmed that this method can accurately detect the occurrence of a quench. Therefore, the pick-up coil can be used as a backup scheme for quench detection.