Human-machine interface (HMI) plays an important role in various fields, where haptic technologies provide crucial tactile feedback that greatly enhances user experience, especially in virtual reality/augmented reality, prosthetic control, and therapeutic applications. Through tactile feedback, users can interact with devices in a more realistic way, thereby improving the overall effectiveness of the experience. However, existing haptic devices are often bulky due to cumbersome instruments and power modules, limiting comfort and portability. Here, we introduce a concept of wearable haptic technology: a thin, soft, self-powered electrotactile textile haptic (SPETH) glove that uses the triboelectric effect and gas breakdown discharge for localized electrical stimulation. Daily hand movements generate sufficient mechanical energy to power the SPETH glove. Its features—softness, lightweight, self-sustainability, portability, and affordability—enable it to provide tactile feedback anytime and anywhere without external equipment. This makes the SPETH glove an enhanced, battery-free HMI suitable for a wide range of applications.
Chronic wound healing is a complex and long-standing problem, that has been a major and critical clinical concern around the world for years. Recent advances in digital wound dressings open new possibilities for solving the problem. Here, we report a battery-free, fully permeable, skin-adhesive, stretchable electronic wound bandage (iSAFE) for intelligent wound management. This electronic bandage exhibits superior properties in multiple features and can be conformally adhered to the skin wound. In addition, the iSAFE can accurately assess the wound conditions in-situ and thus adaptively perform localized drug release. The results from both in vitro and in vivo studies on animals prove the validity of wound monitoring, wound healing boosting and intelligent closed-loop wound management. Clinical trials on patients across age 18 to 95 with various types of wounds are performed. These results all indicate the unique and universality of the reported technology for wound monitoring and management.
The capacity to discern and locate positions in three-dimensional space is crucial for human-machine interfaces and robotic perception. However, current soft electronics can only obtain two-dimensional spatial locations through physical contact. In this study, we report a non-contact position targeting concept enabled by transparent and thin soft electronic skin (E-skin) with three-dimensional sensing capabilities. Inspired by the active electrosensation of mormyroidea fish, this E-skin actively ascertains the 3D positions of targeted objects in a contactless manner and can wirelessly convey the corresponding positions to other devices in real-time. Consequently, this E-skin readily enables interaction with machines, i.e., manipulating virtual objects, controlling robotic arms, and drones in either virtual or actual 3D space. Additionally, it can be integrated with robots to provide them with 3D situational awareness for perceiving their surroundings, avoiding obstacles, or tracking targets.
Cardiovascular digital health technologies potentially outperform traditional clinical equipment through their noninvasive, on-body, and portable monitoring with mass cardiac data beyond the confines of inpatient settings. However, existing cardiovascular wearables have difficulty with providing medical-grade accuracy with a chronically comfortable and stable patient/consumer device interface for reliable clinical decision-making. Here, we develop an intensive care unit (ICU)–grade breathable cardiac electronic skin system (BreaCARES) for real-time, wireless, continuous, and comfortable cardiac care. BreaCARES enables a novel digital cardiac care platform for health care, outpatient diagnostics, stable intraoperative monitoring during heart surgery, and continuous and comfortable inpatient postoperative cardiac care, exhibiting ICU-grade accuracy while having superior anti-interference stability, portability, and long-term on-skin biocompatibility to the clinically and commercially available cardiac monitors in cardiovascular ICUs.
Unmanned aerial vehicles have undergone substantial development and market growth recently. With research focusing on improving control strategies for better user experience, feedback systems, which are vital for operator awareness of surroundings and flight status, remain underdeveloped. Current bulky manipulators also hinder accuracy and usability. Here, we present an enhanced human-machine interface based on skin-integrated multimodal sensing and feedback devices for closed-loop drone control. This system captures hand gestures for intuitive, rapid, and precise control. An integrated tactile actuator array translates the drone’s posture into two-dimensional tactile information, enhancing the operator’s perception of the flight situation. Integrated obstacle detection and neuromuscular electrical stimulation–based force feedback system enable collision avoidance and flight path correction. This closed-loop system combines intuitive controls and multimodal feedback to reduce training time and cognitive load while improving flight stability, environmental awareness, and the drone’s posture. The use of stretchable electronics also addresses wearability and bulkiness issues in traditional systems, advancing human-machine interface design.