Xinge Yu

Dr. Xinge Yu

City University of Hong Kong
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2016 in Nature Materials
Verified
Journal Article
Closed access
Xinge YuXinge Yu
Xinge Yu
TMTobin J. Marks
Tobin J. Marks
AFAntonio Facchetti
Antonio Facchetti

9 March 2023 in ACS Nano
Verified
Journal Article
Closed access
Yifei LuoYifei Luo
Yifei Luo
MAMohammad Reza Abidian
Mohammad Reza Abidian
JAJong-Hyun Ahn
Jong-Hyun Ahn
DADeji Akinwande
Deji Akinwande
AAAnne M. Andrews
Anne M. Andrews
XCXiaodong Chen
Xiaodong Chen

20 November 2019 in Nature
Verified
Journal Article
Closed access
PDF file
Xinge YuXinge Yu
Xinge Yu
Zhaoqian XieZhaoqian Xie
Zhaoqian Xie
YYYang Yu
Yang Yu
JLJungyup Lee
Jungyup Lee
Abraham Vázquez-GuardadoAbraham Vázquez-Guardado
Abraham Vázquez-Guardado
John A. RogersJohn A. Rogers
John A. Rogers

27 March 2024 in Nature
Verified
Journal Article
Closed access
PDF file
BZBinbin Zhang
Binbin Zhang
JLJiyu Li
Jiyu Li
JZJingkun Zhou
Jingkun Zhou
LCLung Chow
Lung Chow
GZGuangyao Zhao
Guangyao Zhao
Xinge YuXinge Yu
Xinge Yu

15 May 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
Binghao WangBinghao Wang
Binghao Wang
ATAnish Thukral
Anish Thukral
Zhaoqian XieZhaoqian Xie
Zhaoqian Xie
LLLimei Liu
Limei Liu
XZXinan Zhang
Xinan Zhang
AFAntonio Facchetti
Antonio Facchetti
Fiber-based electronics enabling lightweight and mechanically flexible/stretchable functions are desirable for numerous e-textile/e-skin optoelectronic applications. These wearable devices require low-cost manufacturing, high reliability, multifunctionality and long-term stability. Here, we report the preparation of representative classes of 3D-inorganic nanofiber network (FN) films by a blow-spinning technique, including semiconducting indium-gallium-zinc oxide (IGZO) and copper oxide, as well as conducting indium-tin oxide and copper metal. Specifically, thin-film transistors based on IGZO FN exhibit negligible performance degradation after one thousand bending cycles and exceptional room-temperature gas sensing performance. Owing to their great stretchability, these metal oxide FNs can be laminated/embedded on/into elastomers, yielding multifunctional single-sensing resistors as well as fully monolithically integrated e-skin devices. These can detect and differentiate multiple stimuli including analytes, light, strain, pressure, temperature, humidity, body movement, and respiratory functions. All of these FN-based devices exhibit excellent sensitivity, response time, and detection limits, making them promising candidates for versatile wearable electronics.

15 October 2018 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
YMYinji Ma
Yinji Ma
JCJungil Choi
Jungil Choi
AHAurélie Hourlier-Fargette
Aurélie Hourlier-Fargette
YXYeguang Xue
Yeguang Xue
HCHa Uk Chung
Ha Uk Chung
YHYonggang Huang
Yonggang Huang
Continuous monitoring of blood pressure, an essential measure of health status, typically requires complex, costly, and invasive techniques that can expose patients to risks of complications. Continuous, cuffless, and noninvasive blood pressure monitoring methods that correlate measured pulse wave velocity (PWV) to the blood pressure via the Moens−Korteweg (MK) and Hughes Equations, offer promising alternatives. The MK Equation, however, involves two assumptions that do not hold for human arteries, and the Hughes Equation is empirical, without any theoretical basis. The results presented here establish a relation between the blood pressure P and PWV that does not rely on the Hughes Equation nor on the assumptions used in the MK Equation. This relation degenerates to the MK Equation under extremely low blood pressures, and it accurately captures the results of in vitro experiments using artificial blood vessels at comparatively high pressures. For human arteries, which are well characterized by the Fung hyperelastic model, a simple formula between P and PWV is established within the range of human blood pressures. This formula is validated by literature data as well as by experiments on human subjects, with applicability in the determination of blood pressure from PWV in continuous, cuffless, and noninvasive blood pressure monitoring systems. Significance Continuous, cuffless, and noninvasive blood pressure monitoring by measuring the pulse wave velocity is generally considered to be a promising technique for noninvasive measurements. Previously reported relations between blood pressure and pulse wave velocity relation involve unrealistic assumptions that do not hold for human arteries, and also rely on empirical expressions without any theoretical basis. Here, an analytical model without such assumptions or empirical expressions is established to yield a relation between blood pressure and pulse wave velocity that has general utility for future work in continuous, cuffless, and noninvasive blood pressure monitoring.