J. Alex

J. Alex

Auto-generated profile, based on publicly available information

J. Alex

Ifak, Institute for Automation and Communication, Steinfeldstrasse, 39179 Barleben, Germany

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2004 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
Guenter LangergraberGuenter Langergraber
Guenter Langergraber
LRL. Rieger
L. Rieger
SWS. Winkler
S. Winkler
JAJ. Alex
J. Alex
JWJ. Wiese
J. Wiese
MMM. Maurer
M. Maurer
A guideline for simulation studies of wastewater treatment plants is proposed. The aim of the HSG-guideline is to define a reference quality level that helps to make the results of simulation studies comprehensible and comparable and therefore increases the quality and reliability of mathematical modelling in wastewater treatment. The paper gives a summary of the HSG-guideline, written by a group of university members from Germany, Austria and Switzerland.

1 January 2003 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
LRL. Rieger
L. Rieger
JAJ. Alex
J. Alex
SWS. Winkler
S. Winkler
MBM. Boehler
M. Boehler
MTM. Thomann
M. Thomann
HSH. Siegrist
H. Siegrist
To ensure correctly operating control systems, the measurement and control equipment in WWTPs must be mutually consistent. The dynamic simulation of activated sludge systems could offer a suitable tool for designing and optimising control strategies. Ideal or simplified sensor models represent a limiting factor for comparability with field applications. More realistic sensor models are therefore required. Two groups of sensor models are proposed on the basis of field and laboratory tests: one for specific sensors and another for a classification of sensor types to be used with the COST simulation benchmark environment. This should lead to a more realistic test environment and allow control engineers to define the requirements of the measuring equipment as a function of the selected control strategy.

1 February 2002 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
UJU. Jeppsson
U. Jeppsson
JAJ. Alex
J. Alex
MPM.N. Pons
M.N. Pons
HSH. Spanjers
H. Spanjers
Peter VanrolleghemPeter Vanrolleghem
Peter Vanrolleghem
The status of instrumentation, control and automation (ICA) within the European wastewater community is reviewed and some major incentives and bottlenecks are defined. Future trends of ICA are also discussed. The information is based on a COST 624 workshop and a non-exhaustive survey with regard to ICA carried out in 13 European countries during March 2001. The level of instrumentation (type of sensors, usage frequency, etc.) and how these instruments are used for on-line control purposes are presented for each individual country (Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Netherlands, Romania, Slovenia, Spain, Sweden and Switzerland). The most common types of applied real-time control in wastewater treatment plants are given. One conclusion of the paper is that sensors no longer represent the main bottleneck for on-line control, rather the lack of plant flexibility is more troublesome. Moreover, the current transitional phase of the wastewater industry in Europe represents a unique opportunity to apply ICA on a large scale. The driving forces are simply too strong to ignore.

1 February 2002 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
JAJ. Alex
J. Alex
GKG. Kolisch
G. Kolisch
KKK. Krause
K. Krause
The objective of this presented project is to use the results of an CFD simulation to automatically, systematically and reliably generate an appropriate model structure for simulation of the biological processes using CSTR activated sludge compartments. Models and dynamic simulation have become important tools for research but also increasingly for the design and optimisation of wastewater treatment plants. Besides the biological models several cases are reported about the application of computational fluid dynamics (CFD) to wastewater treatment plants. One aim of the presented method to derive model structures from CFD results is to exclude the influence of empirical structure selection to the result of dynamic simulations studies of WWTPs. The second application of the approach developed is the analysis of badly performing treatment plants where the suspicion arises that bad flow behaviour such as short cut flows is part of the problem. The method suggested requires as the first step the calculation of fluid dynamics of the biological treatment step at different loading situations by use of 3-dimensional CFD simulation. The result of this information is used to generate a suitable model structure for conventional dynamic simulation of the treatment plant by use of a number of CSTR modules with a pattern of exchange flows between the tanks automatically. The method is explained in detail and the application to the WWTP Wuppertal Buchenhofen is presented.

1 January 2002 in IFAC Proceedings Volumes
Verified
Journal Article
Closed access
PDF file
JAJ. Alex
J. Alex
RTR. Tschepetzki
R. Tschepetzki
UJU. Jumar
U. Jumar

1 February 2002 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
JAJ. Alex
J. Alex
TTT. Binh To
T. Binh To
PHP. Hartwig
P. Hartwig
This paper introduces a model library based on the simulation environment MATLAB/SIMULINK which allows the simulation of the aeration system of an wastewater treatment plant (WWTP). The model library presented covers all parts of an aeration system starting with the compressor set over the common air rail, flow resistances through pipes, controllable valves, aeration membranes and ending last not least with the controllers involved. The main objective of the development of the simulation system is the design, test and the support of the installation of more predictable and efficient control concepts for the aeration system in WWTPs. An example is given to demonstrate the application of the simulation system and to promote a control scheme with a flexible reference value for the pressure at the common air rail based on a most open valve (MOV) concept.