20 March 2024 in IEEE Transactions on Sustainable Computing
Data centers (DCs) are power-intensive facilities which use a significant amount of energy for cooling the servers. Increasing the temperature and relative humidity (RH) setpoints is a rule-of-thumb approach to reducing the DC energy usage. However, the high temperature and RH may undermine the server's reliability. Before we can choose the proper temperature and RH settings, it is essential to understand how the temperature and RH setpoints affect the DC power usage and server's reliability. To this end, we constructed and experimented with an air-cooled DC testbed in Singapore, which consists of a direct expansion cooling system and 521 servers running real-world application workloads. This paper presents the key measurement results and observations from our 11-month experiments. Our results suggest that by operating at a supply air temperature setpoints of 29 ${}^{\circ }$ C, our testbed achieves substantial cooling power saving with little impact on the server's reliability. Furthermore, we present a total cost of ownership (TCO) analysis framework which guides settings of the temperature and RH for a DC. Our observations and TCO analysis framework will be useful to future efforts in building and operating air-cooled DCs in tropics and beyond.
19 December 2023 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Identifying new sensing modalities for indoor localization is an interest of research. This paper studies powerline-induced alternating magnetic field (AMF) that fills the indoor space for the orientation-aware three-dimensional (3D) simultaneous localization and mapping (SLAM). While an existing study has adopted a uniaxial AMF sensor for SLAM in a plane surface, the design falls short of addressing the vector field nature of AMF and is therefore susceptible to sensor orientation variations. Moreover, although the higher spatial variability of AMF in comparison with indoor geomagnetism promotes location sensing resolution, extra SLAM algorithm designs are needed to achieve robustness to trajectory deviations from the constructed map. To address the above issues, we design a new triaxial AMF sensor and a new SLAM algorithm that constructs a 3D AMF intensity map regularized and augmented by a Gaussian process. The triaxial sensor's orientation estimation is free of the error accumulation problem faced by inertial sensing. From extensive evaluation in eight indoor environments, our AMF-based 3D SLAM achieves sub-1m to 3m median localization errors in spaces of up to 500 m2, sub-2° mean error in orientation sensing, and outperforms the SLAM systems based on Wi-Fi, geomagnetism, and uniaxial AMF by more than 30%.
6 January 2022 in ACM Transactions on Cyber-Physical Systems
At present, a co-location data center often applies an identical and low temperature setpoint for its all server rooms. Although increasing the temperature setpoint is a rule-of-thumb approach to reducing the cooling energy usage, the tenants may have different mentalities and technical constraints in accepting higher temperature setpoints. Thus, supporting distinct temperature setpoints is desirable for a co-location data center in pursuing higher energy efficiency. This calls for a new cooling power attribution scheme to address the inter-room heat transfers that can be up to 9% of server load as shown in our real experiments. This article describes our approaches to estimating the inter-room heat transfers, using the estimates to rectify the metered power usages of the rooms’ air handling units, and fairly attributing the power usage of the shared cooling infrastructure (i.e., chiller and cooling tower) to server rooms by following the Shapley value principle. Extensive numeric experiments based on a widely accepted cooling system model are conducted to evaluate the effectiveness of the proposed cooling power attribution scheme. A case study suggests that the proposed scheme incentivizes rational tenants to adopt their highest acceptable temperature setpoints under a non-cooperative game setting. Further analysis considering distinct relative humidity setpoints shows that our proposed scheme also properly and inherently addresses the attribution of humidity control power.