Yew-wah Wong

Mr. Yew-wah Wong


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
PSPradeep Shakya
Pradeep Shakya
GNGimson Ng
Gimson Ng
XZXiaoli Zhou
Xiaoli Zhou
YWYew-wah Wong
Yew-wah Wong
SDSwapnil Dubey
Swapnil Dubey
Shunzhi QianShunzhi Qian
Shunzhi Qian
A hybrid cooling system which combines natural ventilation with a radiant cooling system for a hot and humid climate was studied. Indirect evaporative cooling was used to produce chilled water at temperatures slightly higher than the dew point. With this hybrid system, the condensation issue on the panel surface of a chilled ceiling was overcome. A computational fluid dynamics (CFD) model was employed to determine the cooling load and the parameters required for thermal comfort analysis for this hybrid system in an office-sized, well-insulated test room. Upon closer investigation, it was found that the thermal comfort by the hybrid system was acceptable only in limited outdoor conditions. Therefore, the hybrid system with a secondary fresh air supply system was suggested. Furthermore, the energy consumptions of conventional all-air, radiant cooling, and hybrid systems including the secondary air supply system were compared under similar thermal comfort conditions. The predicted results indicated that the hybrid system saves up to 77% and 61% of primary energy when compared with all-air and radiant cooling systems, respectively, while maintaining similar thermal comfort.

1 November 2002 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
YWYew-wah Wong
Yew-wah Wong
WCWeng Kong Chan
Weng Kong Chan
SYS.C.M. Yu
S.C.M. Yu
LCLeok Poh Chua
Leok Poh Chua

6 January 2022 in ACM Transactions on Cyber-Physical Systems
Verified
Journal Article
Open access
RWRongrong Wang
Rongrong Wang
Duc Van LeDuc Van Le
Duc Van Le
RTRui Tan
Rui Tan
YWYew-wah Wong
Yew-wah Wong
At present, a co-location data center often applies an identical and low temperature setpoint for its all server rooms. Although increasing the temperature setpoint is a rule-of-thumb approach to reducing the cooling energy usage, the tenants may have different mentalities and technical constraints in accepting higher temperature setpoints. Thus, supporting distinct temperature setpoints is desirable for a co-location data center in pursuing higher energy efficiency. This calls for a new cooling power attribution scheme to address the inter-room heat transfers that can be up to 9% of server load as shown in our real experiments. This article describes our approaches to estimating the inter-room heat transfers, using the estimates to rectify the metered power usages of the rooms’ air handling units, and fairly attributing the power usage of the shared cooling infrastructure (i.e., chiller and cooling tower) to server rooms by following the Shapley value principle. Extensive numeric experiments based on a widely accepted cooling system model are conducted to evaluate the effectiveness of the proposed cooling power attribution scheme. A case study suggests that the proposed scheme incentivizes rational tenants to adopt their highest acceptable temperature setpoints under a non-cooperative game setting. Further analysis considering distinct relative humidity setpoints shows that our proposed scheme also properly and inherently addresses the attribution of humidity control power.