Dongwook Kim

Dongwook Kim

Auto-generated profile, based on publicly available information

Dongwook Kim

School of Energy Systems Engineering, Chung-Ang University, Seoul, South Korea

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DKDongwook Kim
Dongwook Kim
JSJong-Won Shin
Jong-Won Shin
An in-depth analysis on the load transient operation of a buck converter with auxiliary current control is presented in this article. The analysis quantifies the effects of nonideal characteristics, such as the equivalent series resistance, inductor current and output voltage ripples, time delay, and slew rate of the load current, on the fluctuation of the output voltage in a practical implementation. The analysis results reveals that some of the non-idealities may cancel each other out and become negligible in the implementation. A design considering the nonidealities can achieve the transient-wise capacitor charge balance of the output capacitor and minimize the output voltage deviation during the load transient. The agreement between the simulation and experimental results validates the effectiveness and precision of the proposed analysis and design.

5 January 2021 in IEEE Access
Verified
Journal Article
Open access
DKDongwook Kim
Dongwook Kim
JBJongun Baek
Jongun Baek
JLJisu Lee
Jisu Lee
JSJoonho Shin
Joonho Shin
JSJong-Won Shin
Jong-Won Shin
A control circuit for the auxiliary buck/boost converter was designed and implemented to improve the load transient response of the buck converter. The circuit shapes the auxiliary inductor current in the critical conduction mode through peak current mode control. The soft-switching operation of the auxiliary switches minimizes the power loss and thus increases the efficiency of the auxiliary converter. Along with the design guidelines and estimated power loss to improve the performance of the proposed control technique, the implementation of the control circuit is explained in detail. Simple analog ICs such as operational amplifiers and comparators, and a couple of logic gates suffices the realization of the proposed control. A prototype buck converter whose input voltage, output voltage, and switching frequency were 15 V, 3.3 V, and 200 kHz, respectively were tested with the implemented control circuit to verify the performance of the proposed control technique.