20 January 2023 in Journal of Materials Science: Materials in Electronics
Due to the instability and toxicity issues of lead/tin-based halide perovskites, lead-free metal halide perovskites have emerged as an attractive lead replacement for several semiconductor applications. Here, we present a bismuth (Bi)-based perovskite structure as a low-toxic and potentially substitutable alternative to lead-based perovskite solar cells. The synthesis and optical performance of MAPbI3, MA3Bi2I9Clx, and (MAPbI3:BiCl3) with ratios (of 10, 30, 50, 70)% as lead-free and low lead perovskite are prepared. The grinding technique is used as a green chemistry method compared to a typical reaction for scaling up production. The phase identification, crystallinity, thermal stability, optoelectronic properties, and nanoscale composition are comprised. The results showed that the prepared samples are enhanced in the visible absorption region and aligned well with previous literature. Besides, the bandgap energy for the mixed-structured perovskite, at a molar ratio of 10%, was reduced to 1.52 eV compared to 1.55 and 1.80 eV for MAPbI3, MA3Bi2I9Clx, respectively. At room temperature, the samples emitted intense photoluminescence in the 680–700 nm region. Our findings demonstrate the processability of bismuth perovskites, aiding in the development of high-performance low toxic perovskites by assisting in the refinement of materials and processing methods.
1 September 2018 in Optik
1 January 2020 in Egyptian Journal of Chemistry
Signal-to-noise (S/N) ratio theory has proven to be useful in understanding, designing, and optimizing spectrophotometric measurement systems. Although a narrower spectral bandwidth does improve the resolution of closely spaced peaks, it also decreases the Signal-to-noise ratio. The narrowest slit width should be used that will yield an acceptable Signal-to-noise ratio. In this research, the wavelengths of peak absorbance of the holmium glass filter were determined to attain the optimum Signal-to-noise ratio accompanied with spectral bandwidths of 0.1 nm, 0.2 nm, 0.5 nm, 0.8 nm, 1 nm, 2 nm, 3 nm and 5 nm. The influence of spectral bandwidth on the Signal-to-noise ratio was by far the most important parameter affecting the location of the measured wavelengths of absorbance or transmittance of the sample.
1 June 2019 in Journal of Physics: Conference Series
The main purpose of this research is to evaluate irradiance levels delivered by non-conventional phototherapy devices.This evaluation can help to save energy, achieve better treatment and improves available intensive phototherapy quality in use in several hospitals in Egypt. The irradiated energy and uniformity of non-conventional phototherapy devices (n=36) were evaluated at nine hospitals in Egypt. These devices were categorized as three groups including; bilibeds with LEDs, bilibed with fluorescent lamps and bilisphere. The irradiance levels were measured using a phototherapy radiometer. The results show that the irradiance levels ranged from 20.3 to 93.1μW.cm-2.nm-1 and the LEDs bilibed devices produce average irradiance levels approximately double of those results from bilisphere with fluorescent lamps. Otherwise, the bilibed with fluorescent lamps (present about 30 % of the non-conventional phototherapy devices studied) is not adequate for intensive phototherapy. Any assessment of the irradiance energy of the phototherapy devices using a suitable calibrated sensor (radiometer) is mandatory in developing countries. The phototherapy devices that produces an adequate and accurate irradiance levels would increase the degradation rate of bilirubin in the blood and hence minimize the necessity to blood transfusion substitution. LEDs bilibeds produce sufficient electromagnetic energy for jaundice treatment. It can be used alone for intensive treatment better than the bilibed with fluorescent lamps and the bilisphere.
2 December 2014 in International Journal of Metrology and Quality Engineering
Illumination using artificial light sources is common in these days. Many manufactures are paying for the design of lamps depending on high efficacy and low UV hazards. This research is focusing on the most useable lamps in the Egyptian markets; high pressure mercury (HPM), metal Halide (MH), and high pressure sodium (HPS). A set up for relative spectral power distribution based on single monochromator and UVA silicon detector for absolute irradiance measurements are used. The absolute irradiance in (W/m2) in UVA region of the lamps and their accompanied standard uncertainty are evaluated.
8 November 2018 in Applied Optics
The main aim of this research is to assess the variation in phototherapy radiometer responsivities toward the optical power of the phototherapeutic devices and hence estimate the spectral mismatch correction factor . Two conventional phototherapy devices were studied to verify their spectral irradiance and three different phototherapy radiometers were studied for their responsivity at the range 400–500 nm. The results show the dependence of total irradiance measurement of phototherapy sources on matching between phototherapy radiometer band responsivity and spectral irradiance of the phototherapy sources. The spectral mismatch values vary from 13% to 47% of the total measured irradiance for the three radiometers. These mismatch values could be added to the measured irradiance as a correction.