6 April 2020 in Pediatric Traumatology, Orthopaedics and Reconstructive Surgery
Background. Despite the wide range of studies, the development of osteoplastic material, which has not only osteoconductive but also osteoinductive properties, remains an extremely topical issue in modern medical materials science. This work is devoted to experimental evaluation of the effectiveness of synthetic osteoplastic composite material based on chitosan and hydroxyapatite. Aim. This study aimed to determine the effects of spongy implants based on chitosan and its composite with hydroxyapatite nanoparticles in an amount of 50 wt. % on early osteogenesis in the area of the through defect of the ileum. Materials and methods. The studied materials were sponge implants based on chitosan and its composite with hydroxyapatite nanoparticles in an amount of 50 wt. %. Comparison groups include those without implant placement and those with replacement with commercial Reprobone osteoplastic material. Materials were implanted into the zone of the through defect of the ileum of rabbits for a period of 28 days. Results. A high rate of resorption of materials based on chitosan in bone tissue and active growth of reticulofibrotic bone tissue along the edges of the defect was established, and the formation of cartilaginous islands and bone marrow was recorded in the group of chitosan implants with hydroxyapatite. The aseptic effect was observed with the use of implants made of chitosan and hydroxyapatite. Conclusions. The data obtained allow us to argue about the osteoconductivity of the studied materials and the prospects for further development in this direction.
26 November 2019 in AIP Conference Proceedings
Thermal plasma effects have long been employed for tissue coagulation, cutting, desiccation, and cauterizing for a long time. Nevertheless, there have been significant developments in cold atmospheric plasma (CAP) with well-controlled temperatures below 40℃. Thereby, in the last decade, a new innovative field, often referred to as plasma medicine, has emerged. Effective using of a handheld portable custom designed plasma jet generator for biomedical applications is reported. Portable CAP-generator (∼ 80 g weight) is operated in self-repetitive nanosecond pulse corona discharge at atmospheric pressure air without any external feed gas. The generator has diverse positive results in biomedical applications due to production of reactive oxygen and nitrogen species (RONS). In vitro experiments with human fibroblasts were carried out. As a result, the optimal plasma exposure time promoting maximum fibroblasts proliferation was determined. Additionally, various experiments of in vivo rat’s wounds healing by CAP treatment have been conducted. As a result of the research, control-group mortality was 80%, and in contrast to this it was 10% in the plasma treated group. Resulting from the points mentioned above, the custom designed CAP-generator could be a useful tool for sterilization of contaminated areas, and for wound healing.
1 January 2018 in Bulletin of Pirogov National Medical & Surgical Center
22 September 2022 in Pediatric Traumatology, Orthopaedics and Reconstructive Surgery
ТГТория Вахтанг Гамлетович
+7
BACKGROUND: Treatment of children with congenital deformity with unsegmented rod and rib synostosis is an important and topical problem to date. Topical publications present the results of surgical correction efficacy and analysis of treatment complications. The extremely important aspect of treatment efficacy assessment regarding changes in the function of external respiration is still topical. AIM: This study aimed to analyze the treatment results of children with congenital scoliosis and unilateral segmentation disorder of the lateral surfaces of the vertebral bodies and rib synostosis. MATERIALS AND METHODS: This is a retrospective monocenter cohort study of the treatment outcomes of 30 patients aged 114 years. In the preoperative period, external respiration was evaluated by pulse oscillometry, multi-slice computed tomography, digital X-ray imaging of the craniopelvis in two projections. All patients underwent expanding thoracoplasty with osteotomy of the rib synostosis and fixation with a rib-costal or rib-vertebral distractor. Control studies were performed every 6 months after the surgical intervention. The average follow-up period was 2 years. Nonparametric analysis was applied to estimate the obtained data. RESULTS: The median (Me) age at the start of treatment was 6 years (interquartile range, 4.25; IQR hereafter). The Me scoliosis before treatment was 74 (IQR, 22.75). The Me scoliosis correction after the first stage of treatment was 16 (IQR, 11) and the second correction achieved 6 (IQR, 13). The Me kyphosis was 15 (IQR, 32), the first intervention improved kyphosis by 4 (IQR, 16), and the second by 6 (IQR, 11). Complications were represented by the destabilization of the metal construct in six cases, and trophic disorders of soft tissues were noted in four. The assessment of external respiratory function using IOM demonstrates reliable improvement of resistive component, reactive component, and frequency dependence of the resistive component (p 0,01). CONCLUSIONS: The assessment of the external respiratory function in young children and analysis of reference values may allow their use as absolute indications for surgical treatment in children with congenital scoliosis with unsegmented bar and rib synostosis.
30 October 2018 in Pediatrician (St. Petersburg)
АВАрцимович Илья Валерьевич
Арцимович Илья Валерьевич
+16
The results of three-year research on the use of allogeneic mesenchymal stem cells of adipose tissue (AMSCs) in the treatment of skin burns of II-III degree are presented. in a complex with wounds dressing of nanofibers chitosan and copolyamide, hyaluronic acid. It was found that with surgical necrectomy, introduction of AMSCs and substitution of defects with natural polymer coatings, the healing time is reduced by 89% (p < 0.05). Isolated administration of MSC reduces the healing period by no more than 5% (p > 0.05). The combined use of wounds dressings of nanofibers chitosan and copo lyamide with MSC accelerates the regeneration process by 26% (p < 0.05), with the introduction of AMSCs accelerating the development of granulation tissue by the fifth day of observation by 83% (p < 0.01). Joint use of wound coverings on the basis of hyaluronic acid with AMSCs is accompanied by an increase in the number of vessels of the microcirculatory bed in the defect area by 185% (p < 0.01). Clinical evaluation of the effectiveness of drugs with stem cells – a gel for topical application and a suspension of MSC LC for injection administration demonstrate their ability to optimize regeneration in the burn zone. Application of gel with AMSCs reduces the duration of epithelialization of border (dermal) burns by 2.2-2.4 times, with the final healing period being reduced by 59% (p < 0.01) and the suppuration frequency by 30% (p < 0.05). The introduction of a suspension of AMSCs into the zone of deep burn increases the frequency of engraftment of autografts, stimulates angiogenesis and proliferation of fibroblasts in the superficial and deep layers of the dermis. In the area of MSC administration, the LC perfusion level and the amplitude of blood flow fluctuation are twice as high as the values in the zones without the introduction of cells.