Alison Su

Alison Su

Auto-generated profile, based on publicly available information

Alison Su

The UC Berkeley/UCSF Graduate Program in Bioengineering, University of California Berkeley, Berkeley, California 94720, United States

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2019 in Analytical Chemistry
Verified
Journal Article
Closed access
ASAlison Su
Alison Su
BSBenjamin E. Smith
Benjamin E. Smith
AHAmy E. Herr
Amy E. Herr

27 January 2020 in Analytical Chemistry
Verified
Journal Article
Closed access
SJShaheen Jeeawoody
Shaheen Jeeawoody
KYKevin A. Yamauchi
Kevin A. Yamauchi
ASAlison Su
Alison Su
AHAmy E. Herr
Amy E. Herr

1 January 2021 in Journal of Research of the National Institute of Standards and Technology
Verified
Journal Article
Open access
AGAlisha Geldert
Alisha Geldert
HBHalleh B. Balch
Halleh B. Balch
AGAnjali Gopal
Anjali Gopal
ASAlison Su
Alison Su
SGSamantha Grist
Samantha Grist
AHAmy E. Herr
Amy E. Herr
Ultraviolet-C (UV-C) decontamination holds promise in combating the coronavirus disease 2019 pandemic, particularly with its potential to mitigate the N95 respirator shortage. Safe, effective, and reproducible decontamination depends critically on UV-C dose, yet dose is frequently measured and reported incorrectly, which results in misleading and potentially harmful protocols. Understanding best practices in UV-C dose measurement for N95 respirator decontamination is essential to the safety of medical professionals, researchers, and the public. Here, we outline the fundamental optical principles governing UV-C irradiation and detection, as well as the key metrics of UV-C wavelength and dose. In particular, we discuss the technical and regulatory distinctions between UV-C N95 respirator decontamination and other applications of germicidal UV-C, and we highlight the unique considerations required for UV-C N95 respirator decontamination. Together, this discussion will inform best practices for UV-C dose measurement for N95 respirator decontamination during crisis-capacity conditions.

8 March 2021 in medRxiv
Verified
Preprint
Open access
PDF file
AGAlisha Geldert
Alisha Geldert
ASAlison Su
Alison Su
ARAllison W. Roberts
Allison W. Roberts
GGGuillaume Golovkine
Guillaume Golovkine
SGSamantha Grist
Samantha Grist
AHAmy E. Herr
Amy E. Herr
During public health crises like the COVID-19 pandemic, ultraviolet-C (UV-C) decontamination of N95 respirators for emergency reuse has been implemented to mitigate shortages. However, decontamination efficacy across N95s is poorly understood, due to the dependence on received UV-C dose, which varies across the complex three-dimensional N95 shape. Robust quantification of UV-C dose across N95 facepieces presents challenges, as few UV-C measurement tools have sufficient 1) small, flexible form factor, and 2) angular response. To address this gap, we combine optical modeling and quantitative photochromic indicator (PCI) dosimetry with viral inactivation assays to generate high-resolution maps of “on-N95” UV-C dose and concomitant SARS-CoV-2 viral inactivation across N95 facepieces within a commercial decontamination chamber. Using modeling to rapidly identify on-N95 locations of interest, in-situ measurements report a 17.4 ± 5.0-fold dose difference across N95 facepieces in the chamber, yielding 2.9 ± 0.2-log variation in SARS-CoV-2 inactivation. UV-C dose at several on-N95 locations was lower than the lowest-dose locations on the chamber floor, highlighting the importance of on-N95 dose validation. Overall, we couple optical simulation with in-situ PCI dosimetry to relate UV-C dose and viral inactivation at specific on-N95 locations, informing the design of safe and effective decontamination protocols.

19 July 2020 in medRxiv
Verified
Preprint
Open access
PDF file
ASAlison Su
Alison Su
SGSamantha Grist
Samantha Grist
AGAlisha Geldert
Alisha Geldert
AGAnjali Gopal
Anjali Gopal
AHAmy E. Herr
Amy E. Herr
With COVID-19 N95 respirator shortages, frontline medical personnel are forced to reuse this disposable – but sophisticated – multilayer textile respirator. Widely used for decontamination of nonporous surfaces, UV-C light has germicidal efficacy on porous, non-planar N95 respirators when ≥1.0 J/cm 2 dose is applied across all surfaces. Here, we address outstanding limitations of photochromic indicators (qualitative readout and insufficient dynamic range) and introduce a photochromic UV-C dose quantification technique for: (1) design of UV-C treatments and (2) in-process UV-C dose validation. Our methodology establishes that color-changing dosimetry can achieve the necessary accuracy (>90%), uncertainty (95%). Furthermore, we adapt consumer electronics for accessible quantitative readout and extend the dynamic range >10× using optical attenuators. In a measurement infeasible with radiometers, we observe striking 20× dose variation over 3D N95 facepieces. By transforming photochromic indicators into quantitative dosimeters, we illuminate critical design considerations for both photochromic indicators and UV-C decontamination.

1 October 2021 in Photochemistry and Photobiology
Verified
Journal Article
Closed access
PDF file
ASAlison Su
Alison Su
AGAlisha Geldert
Alisha Geldert
SGSamantha Grist
Samantha Grist
AHAmy E. Herr
Amy E. Herr