Ahmmad A. Abbass

Ahmmad A. Abbass

Auto-generated profile, based on publicly available information

Ahmmad A. Abbass

Building and Construction Materials Department, Shatrah Technical Institute, Southern Technical University, Shatrah 64007, Iraq

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2019 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
AAAhmmad Abbass
Ahmmad Abbass
Sallal Rashid AbidSallal Rashid Abid
Sallal Rashid Abid
MÖMustafa Özakça
Mustafa Özakça
In this study, an experimental work was directed toward comparing the flexural behavior of solid and hollow steel fiber‐reinforced concrete beams. For this purpose, eight square cross‐sectional beam specimens, four solid and four hollow, were prepared. One concrete mixture with four different steel fiber contents of 0, 0.5, 1.0, and 1.5% were used. The side length of the central square hole was 80 mm, whereas the cross‐sectional side length was 150 mm. All beams were tested under four‐point monotonic loading until failure. In addition to the solid and hollow beams, cylinders were cast to evaluate the compressive strength, splitting tensile strength, and modulus of elasticity, whereas prisms were used to conduct the fracture test. The test results showed that all fibrous beams failed in flexure, whereas those without fiber exhibited flexural‐shear failure. In general, the flexural behavior of fibrous‐beams was superior to that of beams without fiber. The hollow beams with fiber contents of 0, 0.5, and 1.0% were observed to withstand lower loads at cracking, yielding, and peak stages compared with their corresponding solid beams; this was not the case for the 1.5% fiber hollow beam, which exhibited a higher peak load than its corresponding solid beam. Although all eight beams exhibited ductility indices higher than 3.7, hollow beams exhibited better ductility than solid beams, showing higher ductility index values.

2 September 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Sallal Rashid AbidSallal Rashid Abid
Sallal Rashid Abid
AAAhmmad A. Abbass
Ahmmad A. Abbass
Murali GunasekaranMurali Gunasekaran
Murali Gunasekaran
MAMohammed L. J. Al-Sarray
Mohammed L. J. Al-Sarray
INIslam A. Nader
Islam A. Nader
SASajjad H. Ali
Sajjad H. Ali
The response of plain and fibrous concrete to the scenario of fired structures exposed to repeated impacts from falling fragmented building elements and other objects is experimentally investigated in this study. The experimental program included the casting and testing of specimens with 0%, 0.5%, and 1.0% hooked-end steel fibers (SFs) under the ACI 544-2R repeated-impact test. The impact test was conducted using cylindrical disk specimens, while 100 mm cubes were used to evaluate the residual compressive strength and weight loss. From each mixture, six disks and three cubes were heated to high temperatures of 200, 400, and 600 °C, while a similar set of specimens were tested without heating as a reference group. The results show that SF could significantly improve cracking impact resistance and dramatically boost failure impact numbers. The retained percentage improvements were the highest for specimens heated to 600 °C, which were approximately 250% at the cracking stage and 1680% at the failure stage for specimens with 1.0% SF. The test results also show that the repeated-impact resistance dramatically deteriorated at high temperatures, where the maximal residual cracking and failure impact numbers after exposure to 200, 400, and 600 °C were approximately 20% and 40%, 4% and 7%, and 2.2% and 4%, respectively.

30 July 2022 in Materials
Verified
Journal Article
Open access
PDF file
Sallal Rashid AbidSallal Rashid Abid
Sallal Rashid Abid
AAAhmmad A. Abbass
Ahmmad A. Abbass
Murali GunasekaranMurali Gunasekaran
Murali Gunasekaran
MAMohammed L. J. Al-Sarray
Mohammed L. J. Al-Sarray
INIslam A. Nader
Islam A. Nader
SASajjad H. Ali
Sajjad H. Ali
With the aim of investigating the response of concrete to the dual effect of accidental fire high temperatures and possible induced impacts due to falling fragmented or burst parts or objects, an experimental work is conducted in this study to explore the influence of exposure to temperatures of 200, 400 and 600 °C on the responses of concrete specimens subjected to impact loads. Cylindrical specimens are tested using the recommended repeated impact procedure of the ACI 544-2R test. Three concrete mixtures with concrete nominal design strengths of 20, 40 and 80 MPa are introduced to represent different levels of concrete strength. From each concrete mixture, 24 cylinders and 12 cubes are prepared to evaluate the residual impact resistance and compressive strength. Six cylindrical specimens and three cubes from each concrete mixture are heated to each of the three levels of high temperatures, while the other six cylinders and three cubes are tested without heating as reference specimens. The test results show that the behavior of impact resistance is completely different from that of compressive strength after exposure to high temperatures; the cylindrical specimens lose more than 80% of the cracking and failure impact resistance after exposure to 200 °C, while impact resistance almost vanishes after exposure to 400 and 600 °C. Concrete compressive strength is found to be effective on the unheated impact specimens, where the higher-strength cylinders retain significantly higher impact numbers. This effect noticeably decreases after exposure to 200 and 400 °C, and vanishes after exposure to 600 °C.

30 December 2022 in Fibers
Verified
Journal Article
Open access
PDF file
AAAhmmad A. Abbass
Ahmmad A. Abbass
Sallal Rashid AbidSallal Rashid Abid
Sallal Rashid Abid
AAAli I. Abed
Ali I. Abed
SASajjad H. Ali
Sajjad H. Ali
The ACI 544-2R repeated impact test is known as a low-cost and simple qualitative test to evaluate the impact strength of concrete. However, the test’s main deficiency is the high variability in its results. The effect of steel fibers and the compressive strength of concrete on the variability in repeated impact test results was investigated experimentally and statically in this study. Two batches from four mixtures were prepared and tested for this purpose. Hooked-end steel fibers were utilized in the fibrous mixtures. The mixtures NC, NC-SF0.5 and NC-SF1.0 were normal strength mixtures with 0, 0.5 and 1.0% of steel fibers, respectively, while HC was a plain high-strength mixture. The impact tests were conducted using an automatic testing machine following the setup of the ACI 544-2R repeated impact test. The impact numbers at cracking (N1) and at failure (N2) were recorded for both batches of the four mixtures. The results were also analyzed using the normal probability and Weibull distribution tests. The test results showed that the fibers increased the impact results at the cracking stage and significantly increased the failure impact resistance. Adding 0.5 and 1.0% of steel fibers increased the N1 by up to 66 and 111%, respectively, and increased the N2 by 114 and 374%, respectively. The test results also showed that duplicating the design compressive strength from 40 to 80 MPa increased the impact resistance by up to approximately 190%. The test results revealed no clear trend of an effect of steel fibers and compressive strength on the variability in the test results.