Teresa Figueiredo

Teresa Figueiredo

Auto-generated profile, based on publicly available information

Teresa Figueiredo

Lusíadas Hospital Albufeira, University of Algarve, Algarve, Portugal

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2023 in Health Science Reports
Verified
Journal Article
Open access
SMSérgio Miravent
Sérgio Miravent
MLManuel Duarte Lobo
Manuel Duarte Lobo
TFTeresa Figueiredo
Teresa Figueiredo
CJCarmen Jiménez
Carmen Jiménez
RARui Pedro Pereira de Almeida
Rui Pedro Pereira de Almeida
Background and Aims: The use of ultrasound screening is primarily facilitated by point‐of‐care ultrasound (POCUS) and its integration into healthcare systems is a result of the versatility of this imaging technique. This study intends to compare the accuracy and pertinence of sonographic findings obtained by a sonographer in a Basic Emergency Service (BES) with that of radiologists at referral hospital (RH) in Portugal.Methods: Twenty patients with right upper quadrant (RUQ) pain and suspected cholecystitis or biliary pathology underwent sonography screening using POCUS in the BES. They were then forwarded to the RH where a radiologist performed a conventional ultrasound exam on the same patients. The results of both exams were compared to determine if the findings obtained in the BES were confirmed by the radiologist in the RH.Results: In our sample, 60% of cases were related to biliary pathology, 20% were liver‐related, 10% had hepatopancreatic biliary etiology, and 10% had unknown etiology. A strong association between the sonographic findings in the BES and the RH was found in the variables “Sonographic Murphy sign” (V = 0.859; p = 0.001), “Cholelithiasis/Gallbladder sludge” (V = 0.840; p = 0.001), and “Intrahepatic biliary tract dilatation” (V = 0.717; p = 0.006). Adequate measures of agreement between the findings of the radiographer and radiologist were obtained for the “Sonographic Murphy sign” (k = 0.664; p = 0.001) and the presence of “Cholelithiasis/Gallbladder sludge” (k = 0.712; p = 0.000).Conclusion: Major biliary abnormalities were detected in patients with RUQ pain in BES using sonography. The correlation between the sonographic findings obtained by the sonographers at BES and those obtained by radiologists at the RH in Portugal was strong, showing that POCUS screening could be extended to other similar settings; however, more studies are needed.

18 June 2024 in Journal of Medical Radiation Sciences
Verified
Journal Article
Open access
SMSérgio Miravent
Sérgio Miravent
CBCarmen Jimenez Bermejo
Carmen Jimenez Bermejo
NBNarciso Barbancho
Narciso Barbancho
MLManuel Duarte Lobo
Manuel Duarte Lobo
TFTeresa Figueiredo
Teresa Figueiredo
RARui Pedro Pereira de Almeida
Rui Pedro Pereira de Almeida
Introduction: This study intends to compare the accuracy and pertinence of sonographic findings obtained by a sonographer in a Basic Emergency Service (BES) with the imaging findings at the Referral Hospital (RH).Methods: Thirty‐one patients suspected of having renal pathology underwent initial renal sonography screening with sonographer reporting at the BES and were subsequently referred to the RH for additional imaging examinations. The results of both examinations were compared to verify whether the findings from the BES were confirmed by the radiologist in the RH and to ensure that the patient referrals from BES to RH were appropriate.Results: In our sample, most patients (80%) exhibited varying degrees of pyelocaliceal distension, with nearly half (48%) presenting obstructions. A strong association between the sonographic findings in the BES and the RH was found in the variables “Dilatation of pyelocaliceal system” (V=0.895; p=0.000), “Simple cystic formation” (V=0.878; p=0.000), respectively. There was a statistically significant correlation between BES and RH findings, indicating a strong association between these two variables respectively (k=0.890; p=0.000) and (k=0.870; p=0.000). In this research, an achieved sensitivity of 96% and a specificity of 85% were demonstrated in the identification of pyelocaliceal dilatation.Conclusion: Renal sonographer reporting screening successfully detected abnormalities in the urinary system of patients suspected of having renal colic. The sonographic data obtained at the BES demonstrated a strong correlation with the additional imaging findings from the RH in Portugal. These results suggest that Radiographers/Sonographers can have an important role in the preliminary assessment of urgent renal pathology in remote areas, contributing to a correct referral and early treatment.

26 June 2024 in Imaging
Verified
Journal Article
Open access
PDF file
SMSérgio Miravent
Sérgio Miravent
CBCarmen Jimenez Bermejo
Carmen Jimenez Bermejo
MLManuel Duarte Lobo
Manuel Duarte Lobo
TFTeresa Figueiredo
Teresa Figueiredo
RARui Pedro Pereira de Almeida
Rui Pedro Pereira de Almeida
Screening ultrasound, including Point of Care Ultrasonography (POCUS), is widely utilized for rapid clinical guidance in diverse healthcare settings. In this case report, a 34-year-old male with recurrent biliary colic symptoms underwent a Basic Emergency Service ultrasound, revealing a 13 mm gallbladder calculus and signs of inflammation, and was promptly referred to the hospital for further evaluation and treatment. Medical specialist confirmation at the hospital underscored the significance of early detection through POCUS. Despite inconclusive laboratory results, the detailed ultrasound assessment provided a comprehensive understanding, emphasizing the tool's value in averting complications. Thus, screening ultrasound played a pivotal role in justifying the hospital referral, showcasing its vital role in healthcare, especially in resource-limited settings. The judicious use of POCUS can lead to superior outcomes, avoiding unnecessary referrals for non-emergent cases.