The DFIG has been widely used in the wind power industry due to its technical advantages. However, current researches are being developed aiming at overcoming some of its drawbacks concerning reliability, efficiency and power quality. Since the wind farms are usually located at remote places, connected to weak grids, high reliability is required and some power quality issues deserve attention. This paper proposes a low-complexity, robust control of a DFIG driven by a direct matrix converter based on a model predictive rotor current control. The matrix converter is interesting due to the absence of the bulky and sensitive dc-link capacitors, leading to higher reliability. The predictive control is used to perform speed regulation. Moreover, this combination of converter and straightforward control is proven to be a robust technique that naturally compensates for stator current issues, which arises due to a low-power-quality grid voltage. Besides, a linear model of the proposed system is presented in order to be possible to use the linear-control-theory tools to execute the system control design. A processor-in-the-loop simulation is employed to validate the proposed control.
14 October 2019 in IEEE Transactions on Industry Applications
This article presents the modeling and experimental validation of a recently presented DFIG wind power system driven by a two-level three-phase converter in which the grid-side converter is connected in series with the grid. The series-grid-side converter is able to compensate for stator-voltage sags, unbalance and harmonic distortion resulting in a high-power-quality system with considerable low-voltage-ride-through capability. The proposed control technique makes it feasible to obtain such high-power-quality system using a conventional two-level three-phase converter composed of 12 IGBTs, with no need of extra switches, while maintaining the usual high efficiency and low cost inherent to the DFIG configuration. Moreover, using the proposed linear model, one can design the dc-link-voltage controller's parameters according to the desired dynamic behavior. Experimental results are presented using a 15 kW test bench, which validate the proposed control technique.
1 July 2011 in Molecular Plant-Microbe Interactions®
Oxalic acid (OA) and Nep1-like proteins (NLP) are recognized as elicitors of programmed cell death (PCD) in plants, which is crucial for the pathogenic success of necrotrophic plant pathogens and involves reactive oxygen species (ROS). To determine the importance of oxalate as a source of ROS for OA- and NLP-induced cell death, a full-length cDNA coding for an oxalate decarboxylase (FvOXDC) from the basidiomycete Flammulina velutipes, which converts OA into CO2 and formate, was overexpressed in tobacco plants. The transgenic plants contained less OA and more formic acid compared with the control plants and showed enhanced resistance to cell death induced by exogenous OA and MpNEP2, an NLP of the hemibiotrophic fungus Moniliophthora perniciosa. This resistance was correlated with the inhibition of ROS formation in the transgenic plants inoculated with OA, MpNEP2, or a combination of both PCD elicitors. Taken together, these results have established a pivotal function for oxalate as a source of ROS required for the PCD-inducing activity of OA and NLP. The results also indicate that FvOXDC represents a potentially novel source of resistance against OA- and NLP-producing pathogens such as M. perniciosa, the causal agent of witches' broom disease of cacao (Theobroma cacao L.).
10 August 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
This article proposes a shunt active filter (SAF) operating as a Synchronverter to enhance its performance, including the virtual inertia functionality. The SAF behaves as a voltage source with a low-impedance path for harmonic contents. Synchronverter behavior is used together with selective filtering through proportional-resonant controllers to provide selective harmonic filtering of the load current, selective harmonic blocking of the source current, and low-impedance path for nonselected harmonic contents from the load and the source currents. The virtual inertia functionality aims to contribute to frequency stability during power system transients. Besides filtering unbalanced and harmonic contents and compensating for reactive power, the SAF contributes to inertia response during frequency transients. A tuning design method is proposed to ensure stability and proper conditioning of the power-quality issues. The reduced quantity of parameters to be tuned is another advantage of the proposed controller. Simulation and experimental results validate the compensation performance of the SAF.