In response to global energy, environment, and climate concerns, distributed photovoltaic (PV) power generation has seen rapid growth. However, the intermittent and uncertain nature of PVs can cause voltage fluctuations in distribution systems, threatening their stability. To address this challenge, this paper proposes an active distribution network voltage optimization method, of which the main contribution is the development of a comprehensive voltage optimization strategy that integrates day-ahead prediction and real-time adjustment, significantly enhancing the stability and efficiency of distribution networks with high PV penetration. In the day-ahead prediction stage, the forecast scenarios of load and PV output guide network reconfiguration for improved voltage distribution. In the real-time operation stage, flexible regulation of PV and energy storage systems is used to adjust power outputs, further optimizing voltage quality. Simulations on the IEEE 33-bus system show that the method effectively improves voltage distribution, enhances renewable energy consumption, and ensures the safe, economic operation of the distribution system.
As renewable energy penetration increases, the lack of flexibility in a multi-renewable power system can seriously affect its own economics and reliability. To address this issue, three objectives are considered in this study: power fluctuations on tie-line, operating cost, and curtailment rate of renewable energy. Presented also is an optimal day-ahead scheduling model based on the MREPS for distributed generations with flexibility constraints. The multi-objective particle swarm optimization (MOPSO) algorithm can be applied to obtain a set of Pareto non-dominated solutions for the day-ahead scheduling strategy with the proposed model. By using fuzzy comprehensive evaluation, the optimal compromise solution is determined in the set. The presented method sacrifices a small amount of economy and power fluctuation, but it can reduce the deviation between forecast and realized power fluctuations on the tie-line, while improving the utilization of renewable energy.
Virtual synchronous generators (VSGs) have attracted widespread attention due to their advantage in supporting voltage and frequency of power systems. However, relevant studies have shown that a VSG has similar low-frequency oscillation as synchronous generators, which is more likely to occur under strong grid conditions. In this paper, the linearized mathematical model of a VSG is established by using small-signal analysis; based on this, the physical process of low-frequency oscillation of a VSG is explained from the perspective of vector motion. Firstly, the amplitude and phase motion of the current vector of a VSG under small disturbance are analyzed, then the mechanism of negative damping caused by terminal voltage control is revealed, and the reason why a VSG is more prone to instability under strong grid conditions is explained. Based on these, the influence of control and grid strength on the low-frequency oscillation of a VSG is analyzed. Studies show that the amplitude motion of the output current is the main cause of negative damping, and the oscillation can be suppressed by optimizing the value of key parameters.
Recent studies show that the loss of stability for a voltage-source converter (VSC) in weak-grid connection is largely related to its synchronization unit, i.e., the phase-locked loop (PLL). This paper studies the synchronization stability of a system comprised by two VSCs in parallel connection to a weak grid. A reduced transfer function based small-signal model, which can allow for the interactions between PLL and converter outer power controls, is first proposed. Then, an improved net damping criterion is used to analyze the damping and stability characters of such system under various operating conditions and different controller configurations. Compared to the conventional net damping criterion, the used criterion has wider applicability in terms of stability judgment. Case studies show that the studied system tends to be unstable at weak-grid or heavy-loading conditions. The instability can be in the form of oscillations or monotonic divergence, in which, the latter is more likely to occur for the converters without grid voltage regulation capabilities. Besides, the net damping-based sensitivity studies can provide guidance on control tuning or design for stability enhancement. Detailed model-based time domain simulations are conducted to verify the analysis results.