30 March 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Advanced satellite-based frequency transfers by two-way carrier-phase (TWCP) and integer precise point positioning have been performed between the National Institute of Information and Communications Technology and Korea Research Institute of Standards and Science. We confirm that the disagreement between them is less than 1×10 -16 at an averaging time of several days. In addition, an overseas frequency ratio measurement of Sr and Yb optical lattice clocks was directly performed by TWCP. We achieved an uncertainty at the mid-10 -16 level after a total measurement time of 12 h. The frequency ratio was consistent with the recently reported values within the uncertainty.
23 August 2021 in Metrologia
We report a measurement of the absolute frequency of the 1S0–3P0 transition in the 171Yb optical lattice clock at KRISS (KRISS-Yb1) for 14 months, which was referenced to the SI second by primary and secondary standards worldwide via International Atomic Time. The determined absolute frequency is 518 295 836 590 863.75(14) Hz with the relative frequency uncertainty of 2.6 × 10−16, which agrees well with other reports. This result is expected to contribute to the future update of the CIPM recommendation frequency of the secondary frequency standards.
27 March 2020 in Science Advances
Frequency-stabilized optical frequency combs have created many high-precision applications. Accurate timing, ultralow phase noise, and narrow linewidth are prerequisites for achieving the ultimate performance of comb-based systems. Ultrastable cavity-based comb-noise stabilization methods have enabled sub–10−15-level frequency instability. However, these methods are complex and alignment sensitive, and their use has been mostly confined to advanced metrology laboratories. Here, we have established a simple, compact, alignment-free, and potentially low-cost all-fiber photonics-based stabilization method for generating multiple ultrastable combs. The achieved performance includes 1-femtosecond timing jitter, few times 10−15-level frequency instability, and <5-hertz linewidth, rivalling those of cavity-stabilized combs. This method features flexibility in configuration: As a representative example, two combs were stabilized with 180-hertz repetition rate difference and ~1-hertz relative linewidth and could be used as an ultrastable, octave-spanning dual-comb spectroscopy source. The demonstrated method constitutes a mechanically robust and reconfigurable tool for generating multiple ultrastable combs suitable for field applications.
9 August 2021 in Applied Physics Letters
We introduce a compact atomic clock based on laser-cooled atoms trapped inside a loop-gap microwave cavity. The cavity occupies a volume eight times smaller than conventional cylindrical cavities while maintaining a high quality factor in the presence of the ten apertures required for optical manipulation of cold atoms. The measured linewidth of the Ramsey spectrum, which is limited by the free fall distance of the atomic cloud in the cavity, was 19.6 Hz. The corresponding frequency instability was σy(τ) = 2.5 × 10−12 τ−1/2, which could be further improved by reducing the local oscillator noise. This work paves a way toward high-performance portable atomic clocks.
28 June 2023 in Metrologia
An ensemble time, which is indicated by TA (temps atomique, in French), was generated every minute by combining four active hydrogen masers with the reduced Kalman filter (Kred) algorithm. The TA frequency was averaged over 12 h and then the mean frequency was steered to the primary and secondary frequency standards developed by KRISS with a micro-phase stepper (MPS). The steered and physically realized TA frequency is called KRISS ensemble time (KET). We investigated the frequency-state estimate outputted from the Kred algorithm and the control signal applied to the MPS, according to the abnormal temperature change of the room where the hydrogen masers were placed. When the frequency of the TA was corrected by the KRISS-F1, the Allan deviation of KET was 1.72 × 10−15 at the average time τ = 1 d, and the variation of [UTC–KET] was stable within 2 ns for 75 d.
30 September 2020 in Applied Optics
An experimental method is developed for robust frequency stabilization using a high-finesse cavity when the laser exhibits large intermittent frequency jumps. This is accomplished by applying an additional slow feedback signal from Doppler-free fluorescence spectroscopy in an atomic beam with increased frequency locking range. As a result, a stable and narrow-linewidth 556 nm laser maintains the frequency lock status for more than a week and contributes to more accurate evaluation of the Yb optical lattice clock. In addition, the reference optical cavity is supported at vibration-insensitive points without any vibration isolation table, making the laser setup more simple and compact.