23 August 2021 in Metrologia
We report a measurement of the absolute frequency of the 1S0–3P0 transition in the 171Yb optical lattice clock at KRISS (KRISS-Yb1) for 14 months, which was referenced to the SI second by primary and secondary standards worldwide via International Atomic Time. The determined absolute frequency is 518 295 836 590 863.75(14) Hz with the relative frequency uncertainty of 2.6 × 10−16, which agrees well with other reports. This result is expected to contribute to the future update of the CIPM recommendation frequency of the secondary frequency standards.
24 August 2022 in Metrologia
As optical clocks are improved to reach the frequency uncertainty below the 10−17 level, the frequency shift due to the blackbody radiation (BBR) has been one of the major systematic effects hindering further improvement. To evaluate the BBR shift of an Yb optical lattice clock at KRISS, we installed an in-vacuum BBR shield and made radiation thermometry using a black-coated-sphere thermal probe. After we quantitatively measured the conduction loss of the thermal probe and the effects of all the external radiation sources, we determined the temperature at the atom trap site with an uncertainty of 13 mK, which corresponds to an uncertainty of 0.22 mHz in the clock frequency (a fractional frequency of 4.2 × 10−19). The total uncertainty of the BBR shift including the atomic response is 9.5 × 10−19.
28 June 2023 in Metrologia
An ensemble time, which is indicated by TA (temps atomique, in French), was generated every minute by combining four active hydrogen masers with the reduced Kalman filter (Kred) algorithm. The TA frequency was averaged over 12 h and then the mean frequency was steered to the primary and secondary frequency standards developed by KRISS with a micro-phase stepper (MPS). The steered and physically realized TA frequency is called KRISS ensemble time (KET). We investigated the frequency-state estimate outputted from the Kred algorithm and the control signal applied to the MPS, according to the abnormal temperature change of the room where the hydrogen masers were placed. When the frequency of the TA was corrected by the KRISS-F1, the Allan deviation of KET was 1.72 × 10−15 at the average time τ = 1 d, and the variation of [UTC–KET] was stable within 2 ns for 75 d.
22 January 2024 in Metrologia
Relativistic redshift correction should be accurately considered in frequency comparisons between frequency standards. In this study, we evaluated the relativistic redshift at Korea Research Institute of Standards and Science (KRISS) using three different methods, depending on whether the approach was traditional or modern or whether the geopotential model was global or local. The results of the three methods agreed well with one another, and the height of an Yb optical lattice clock (KRISS-Yb1) was determined to be 75.15 m with an uncertainty of 0.04 m with respect to the conventionally adopted equipotential surface , the value of which is defined to be 62 636 856.0 m2s−2. Accordingly, the relativistic redshift of KRISS-Yb1 was evaluated to be 8.193(4) × 10−15. These data are applicable to the frequency standards at KRISS, one of which regularly participates in the calibration of the International Atomic Time.
1 February 2017 in Review of Scientific Instruments
A flag-type atom shutter based on a rotating lever that is driven by a bender piezoelectric actuator was developed to manipulate atomic beams. The shutter flag was displaced by ∼10 mm to open and close a 5-mm-diameter aperture with a shutter time of 13 ms that produced small mechanical vibrations. The short-term shutter time stability for each cycle was 0.03 ms and the long-term stability over an average of 20 000 cycles was 0.02 ms. The operational cycle number (lifetime) of the shutter reached 2.0 × 106 cycles after an intermittent operation over a period of eight months in an ultra-high vacuum chamber, and another shutter in an atmospheric environment swung for 2.6 × 107 cycles of continuous operation at 5 Hz for a period of 60 days without major problems. The shutter was shown to be compatible with the operation in an ultra-high vacuum at a low 10−7 Pa level after a gentle baking treatment.
30 September 2020 in Applied Optics
An experimental method is developed for robust frequency stabilization using a high-finesse cavity when the laser exhibits large intermittent frequency jumps. This is accomplished by applying an additional slow feedback signal from Doppler-free fluorescence spectroscopy in an atomic beam with increased frequency locking range. As a result, a stable and narrow-linewidth 556 nm laser maintains the frequency lock status for more than a week and contributes to more accurate evaluation of the Yb optical lattice clock. In addition, the reference optical cavity is supported at vibration-insensitive points without any vibration isolation table, making the laser setup more simple and compact.