Based on a two-bar linkage and a magnetorheological damper (MRD) with a double-ended structure and shearing operation mode of the magnetorheological fluid, an MRD-based prosthetic knee (MRPK) is realized. Utilizing the developed MRPK, an MRD-based lower limb prosthesis (MRLLP) is developed, modeled, and simulated in this paper, to analyse the effects of hysteresis of the integrated MRD on the swing angle of the shank of the MRLLP. Based on this, a sliding mode tracking control (SMTC) method for controlling the swing angle of the shank of the MRLLP is proposed to suppress hysteresis, along with a robustness analysis. Utilizing the SMTC method, co-simulations on controlling the swing angle of the shank of the MRLLP are carried out in ADAMS and Simulink. The simulation results show that the root mean square error (RMSE) of the swing angle of the shank of the MRLLP produced by the SMTC method is 80% less than that from the computed torque plus PD (CT+PD) control method. Therefore, the SMTC method is effective in suppressing hysteresis of the MRD. Furthermore, when the MRLLP is disturbed, the RMSE of the swing angle of the shank of the MRLLP produced by the SMTC method is 67% less than that from the CT+PD control method. Therefore, the SMTC method has strong robustness to random disturbance. A rapid control prototype of the MRLLP system and a corresponding experimental test system are established. On the established experimental test system, experiments are carried out on control of the swing angle of the shank of the MRLLP via the SMTC method. The results are compared with those from the ON/OFF and the CT+PD control methods. The experimental results show that the MRPK has controllable joint torque, and can be used to imitate the natural swing of a human knee joint. Additionally, the RMSE of the controlled swing angle of the shank of the MRLLP produced by the SMTC method is 34% less than that produced by the CT+PD control method and is 37% less than that from the ON/OFF control method.
1 November 2015 in Sensors and Actuators A: Physical
Overcoming the disadvantages of direction selectivity and narrow bandwidth are two key problems to improve the efficiency of energy harvesting from ambient vibration, and also the premises of the practical application of the piezoelectric vibration energy harvester. In this paper, utilizing a 3-DOF parallel mechanism and nonlinear magnetic forces generated by polar opposing magnets, a nonlinear piezoelectric vibration energy harvester is proposed and explored. The kinematic equation, the governing equation of motion, and the piezoelectric coupling equation of the vibration energy harvester are established. On this basis, through numerical simulation, the normal modes of the vibration energy harvester in linear case are explored, the effect of the polar opposing magnets and the nonlinear characteristics are analyzed, the 8 potential wells in three-dimensional space of the vibration energy harvester are investigated, and the motion trajectories of the octuplet stable system are estimated. Then, the developed vibration energy harvester is tested with vibration excitation along different directions and sweep excitations. The results show that the developed vibration energy harvester can harvest vibration energy along any directions, and its bandwidth is extended by introducing magnets. The maximum average power of the developed vibration energy harvester is 22.3 mw for 1 g excitation, and the bandwidth is about 5.5 Hz with its center frequency around 11 Hz. This work proves that using parallel mechanism with nonlinearity is a promising solution to realize arbitrary-directional vibration energy harvester with wide bandwidth.
Multi-directional and multi-degree-of-freedom (multi-DOF) vibration energy harvesting are attracting more and more research interest in recent years. In this paper, the principle of a piezoelectric six-DOF vibration energy harvester based on parallel mechanism is proposed to convert the energy of the six-DOF vibration to single-DOF vibrations of the limbs on the energy harvester and output voltages. The dynamic model of the piezoelectric six-DOF vibration energy harvester is established to estimate the vibrations of the limbs. On this basis, a Stewart-type piezoelectric six-DOF vibration energy harvester is developed and explored. In order to validate the established dynamic model and the analysis results, the simulation model of the Stewart-type piezoelectric six-DOF vibration energy harvester is built and tested with different vibration excitations by SimMechanics, and some preliminary experiments are carried out. The results show that the vibration of the limbs on the piezoelectric six-DOF vibration energy harvester can be estimated by the established dynamic model. The developed Stewart-type piezoelectric six-DOF vibration energy harvester can harvest the energy of multi-directional linear vibration and multi-axis rotating vibration with resonance frequencies of 17 Hz, 25 Hz, and 47 Hz. Moreover, the resonance frequencies of the developed piezoelectric six-DOF vibration energy harvester are not affected by the direction changing of the vibration excitation.
In this paper, the method to develop the rapid prototyping of the piezoelectric six-axis accelerometer based on the principle of a six-axis accelerometer proposed by the authors is introduced, which accesses the six degree-of-freedom (DOF) acceleration of the body frame by decoupling the output equations of the six single-axis accelerometers mounted on a rigid body. Utilizing the dSPACE rapid control prototyping (RCP) system, the rapid prototyping of the piezoelectric six-axis accelerometer based on the RCP technique is established. Moreover, the corresponding experimental set-up and experimental results to verify the rapid prototyping of the six-axis accelerometer are presented and analyzed. The experimental results show that the developed rapid prototyping system of the piezoelectric six-axis accelerometer can sense the six-DOF acceleration. The research works in this paper establish the foundation for the development of the piezoelectric six-axis accelerometers.
In this paper, an innovative origami-inspired compliant spherical joint is proposed, aiming to address the challenges in achieving flexible and integrated motion sensing in micro-mechanisms. This joint consists of a thin flexible printed circuit (FPC) lamina sandwiched between two rigid plates. The design features three creases that converge at a given point. Rotation angle sensing of the origami compliant spherical joint is realized by integrating three planar coils into the FPC lamina at these creases. The kinematic equation, sensing equation, and inverse kinematic equation of the compliant spherical joint are established using Denavit-Hartenberg conventions to illustrate the principles and calibration method. Through numerical analysis and simulation, the workspace, sensing resolution, and compliance performance of the compliant spherical joint are investigated. A prototype with dimensions of 60 mm×35 mm×2 mm was developed and tested. The results show that this innovative compliant spherical joint can rotate around three orthogonal axes with maximum angles of ±10°, ±60°, and ±40° respectively. The angular sensing resolution is smaller than 0.5°. The RMS error of the sensed angle relative to the fitted linear regression line is smaller than 0.8° and the sensing error is less than 10.6°. The proposed compliance matrix enables the estimation of the flexibility influence coefficients for various orientations of the compliant spherical joint. Moreover, the developed origami six-degree-of-freedom (DOF) parallel platform further demonstrates that this compliant spherical joint can simplify complex origami mechanisms by providing flexible three-dimensional rotational motion and integrating rotation angle sensing.