Daihua Wang

Prof. Dr. Daihua Wang

Department of Measurement & Control Technology and Instruments, Chongqing University, Chongqing, China

Research Focus & Metrics

Academic Career Length

44Years (1983-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2006 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Closed access
HAH. X. Ai
H. X. Ai
Daihua WangDaihua Wang
Daihua Wang
Wei-Hsin LiaoWei-Hsin Liao
Wei-Hsin Liao
In this article, an MR valve possessing simultaneously annular fluid flow resistance channels and radial fluid flow resistance channels is designed, and its structure and working principle are described. In addition, a mathematical model for the MR valve with both annular and radial flow paths is developed and the simulation is carried out to evaluate the newly developed MR valve. The simulation results based on the proposed model indicate that the efficiency of the MR valve with circular disk-type fluid resistance channels is superior to that with annular fluid resistance channels under the same magnetic flux density and outer radius of the valve. Furthermore, the results also show that the efficiency of the MR valve can be improved significantly with two types of fluid flow resistance gaps, viz. annular fluid flow resistance gaps and circular disk-type fluid flow resistance gaps simultaneously.

1 March 2022 in Smart Materials and Structures
Verified
Journal Article
Closed access
GLGaoyu Liu
Gaoyu Liu
FGFei Gao
Fei Gao
Daihua WangDaihua Wang
Daihua Wang
Wei-Hsin LiaoWei-Hsin Liao
Wei-Hsin Liao
Magnetorheological (MR) fluid, whose rheological properties can be changed reversibly by applied magnetic field, offers superior capabilities and opportunities since its invention. The most crucial feature of MR fluid is its controllable and continuous yield stress. Taking this advantage, MR fluid is gaining popularity in various medical applications to meet their force/torque requirements. In this review article, progress of medical applications of MR fluid in the last two decades are systematically reviewed, mainly focused on six categories: lower limb prosthesis, exoskeleton, orthosis, rehabilitation device, haptic master, and tactile display. With MR fluid, natural and stable limb motions in lower limb prostheses, exoskeletons, and orthoses, flexible muscle trainings in rehabilitation devices, and high transparency and resolution haptic feedback can be realized. Relevant discussions and future perspectives are also provided.

20 March 2017 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
QFQiang Fu
Qiang Fu
Daihua WangDaihua Wang
Daihua Wang
LXLei Xu
Lei Xu
GYGang Yuan
Gang Yuan
Based on a two-bar linkage and a magnetorheological damper (MRD) with a double-ended structure and shearing operation mode of the magnetorheological fluid, an MRD-based prosthetic knee (MRPK) is realized. Utilizing the developed MRPK, an MRD-based lower limb prosthesis (MRLLP) is developed, modeled, and simulated in this paper, to analyse the effects of hysteresis of the integrated MRD on the swing angle of the shank of the MRLLP. Based on this, a sliding mode tracking control (SMTC) method for controlling the swing angle of the shank of the MRLLP is proposed to suppress hysteresis, along with a robustness analysis. Utilizing the SMTC method, co-simulations on controlling the swing angle of the shank of the MRLLP are carried out in ADAMS and Simulink. The simulation results show that the root mean square error (RMSE) of the swing angle of the shank of the MRLLP produced by the SMTC method is 80% less than that from the computed torque plus PD (CT+PD) control method. Therefore, the SMTC method is effective in suppressing hysteresis of the MRD. Furthermore, when the MRLLP is disturbed, the RMSE of the swing angle of the shank of the MRLLP produced by the SMTC method is 67% less than that from the CT+PD control method. Therefore, the SMTC method has strong robustness to random disturbance. A rapid control prototype of the MRLLP system and a corresponding experimental test system are established. On the established experimental test system, experiments are carried out on control of the swing angle of the shank of the MRLLP via the SMTC method. The results are compared with those from the ON/OFF and the CT+PD control methods. The experimental results show that the MRPK has controllable joint torque, and can be used to imitate the natural swing of a human knee joint. Additionally, the RMSE of the controlled swing angle of the shank of the MRLLP produced by the SMTC method is 34% less than that produced by the CT+PD control method and is 37% less than that from the ON/OFF control method.

30 May 2012 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Daihua WangDaihua Wang
Daihua Wang
SWS. J. Wang
S. J. Wang
PJPinggang Jia
Pinggang Jia
Aiming at detecting high intensity focused ultrasound (HIFU) fields, this letter reports on a novel in-line silica capillary tube all-silica fiber-optic Fabry–Perot (ILSCT-ASFP) interferometric sensor fabricated by splicing a commercially available silica capillary tube to two single-mode fibers. The experimental results show that such a novel ILSCT-ASFP interferometric sensor with a cavity length of ∼60.76  μm has an excellent fringe visibility of up to ∼20  dB, and the fringe visibility is still good when the cavity length extends up to ∼1031.07  μm. The measured wavelength-temperature sensitivity of 0.000858  nm/°C shows that the wavelength drift of the fabricated ILSCT-ASFP interferometric sensor towards temperature is extremely low. Meanwhile, the measurement of HIFU fields by this novel sensor is demonstrated, and the experimental results indicate that the signal-to-noise ratio of the sensing system for sensing a 0.93 MHz HIFU field with a pressure of 2.69 MPa in the focus area can reach 42.8 dB. The corresponding noise equivalent pressure is 0.0194 MPa, and the calculated acoustic sensitivity is 65.4  mV/MPa over a 2.5 MHz measurement bandwidth.

6 December 2018 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
Xianxu 'Frank' BaiXianxu 'Frank' Bai
Xianxu 'Frank' Bai
SSSheng Shen
Sheng Shen
Norman M. WereleyNorman M. Wereley
Norman M. Wereley
Daihua WangDaihua Wang
Daihua Wang
The smart fluids—magnetorheological (MR) fluids show the potentials for high-speed shock mitigation applications because of their fast response and large controllable damping range. In order to match the high-speed applications of MR fluids, the structural design and controllability evaluation of MR actuators are of great significance. Controllability of MR actuators are defined to be evaluated by the mechanical behaviors (i.e. damping force controllability), including the controllable damping force range, dynamic range and constant stroking load velocity range, and response time performance (i.e. real-time controllability). We proposed an internal bypass MR shock absorber (MRSA) (Bai et al 2013a IEEE Trans. Mag. 49 3422–5), which presents the possibility in vibration control and shock mitigation applications. In the internal bypass MRSA, the gap formed by the coaxially assembled inner and outer cylinders is the flow channel for MR fluids. The electromagnetic coil windings evenly wound on the outer wall of the inner cylinder and the active rings contribute to the MR effect, and continuous adjustable damping is realized through applying current into the electromagnetic coil windings. In Part I of this paper, the principle and the mechanical behaviors of the internal bypass MRSA is further in-deeply investigated via theoretical modeling and simulations. Based on the fluid dynamics—parallel plate models and the finite element analysis software ANSYS/Fluent, the mathematical model and the fluidic entities of the internal bypass MRSA are established, respectively. Response time model of the internal bypass MRSA under a voltage driver is established. The static magnetic field distributions of the internal bypass MRSA under different current excitations are obtained via ANSYS/Workbench. The response times of the internal bypass MRSA under transient impulse current excitation and transient impulse voltage excitation are obtained by transient electromagnetic simulation. The damping force performance of the conventional unicoil MRSA with an electromagnetic coil winding in positon, multicoil MRSA with five electromagnetic coil windings in positon and the internal bypass MRSA are compared and analyzed. As compared with the conventional unicoil and multicoil MRSAs with coupled structures of the piston and the electromagnetic coil windings, the internal bypass MRSA with decoupled arrangement shows much better damping force controllability. Experimental test and controllability evaluation of the internal bypass MRSA will be conducted and presented in Part II of this paper.

1 November 2010 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Closed access
Daihua WangDaihua Wang
Daihua Wang
WZW. Zhu
W. Zhu
QYQ. Yang
Q. Yang
In this article, in order to linearize the hysteresis behavior of stack piezoelectric ceramic actuators (SPCAs), the feedforward linearization method based on the Bouc-Wen model and the hybrid linearization method combining the feedforward method and PI feedback loop are proposed and explored. The rapid control prototypes of the linearization controllers for the SPCA are established and tested. The research results show that both the feedforward and hybrid linearization methods can linearize the hysteresis behavior and the SPCAs with linearization controllers can be regarded as linear actuators. However, the linearization accuracy using the feedforward method is confined by the modeling error of the Bouc-Wen model. Although the proposed hybrid method combining the feedforward method and the PI feedback loop can reach higher linearization accuracy than that with the feedforward method, the hybrid method will result in high frequency components in the additional voltage, which will have a serious impact on the lifespan of the controlled SPCA. Utilizing the linearization methods proposed in this article, the open-loop and closed-loop controls for the tip displacement of a piezoelectric-driven microgripper are realized, which indicates that the proposed linearization methods can simplify the control of SPCAs and SPCA-based systems with high accuracy.