Tien-Jen Chang

Tien-Jen Chang

Auto-generated profile, based on publicly available information

Tien-Jen Chang

The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN) Department of Health Technology Technical University of Denmark Kgs. Lyngby 2800 Denmark

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2021 in Communications Physics
Verified
Journal Article
Open access
PDF file
TCTien-Jen Chang
Tien-Jen Chang
LVLukas Vaut
Lukas Vaut
MVMartin Voss
Martin Voss
OIOleksii Ilchenko
Oleksii Ilchenko
LNLine Hagner Nielsen
Line Hagner Nielsen
EHEn-Te Hwu
En-Te Hwu
Conventional photopolymerization-based 3D printing still requires developing a concise and cost-effective method to improve the printing resolution at the nanoscale. Here, we propose the use of a gaming console optical drive pickup unit for 3D photopolymerization. This mass-produced optical pickup unit features a finely adjustable diode laser, allowing us to adjust the printing resolution from tens of micrometres down to hundreds of nanometres without requiring oxygen radical scavenging or costly femtosecond lasers. We evaluate the 3D printing performance using a commercial photopolymer under different laser exposure parameters. The proposed printing system achieves a resolution of 385 nm along the lateral direction and XYZ nano-resolution linear stages enable a printing volume of up to 50 × 50 × 25 mm3. Finally, we demonstrate the fabrication of 3D stereoscopic microstructures. The substantially simplified optics proposed here paves the way for affordable high-resolution micro/nanoscale 3D fabrication.

4 December 2022 in Advanced Healthcare Materials
Verified
Journal Article
Open access
TCTien‐Jen Chang
Tien‐Jen Chang
RKRolf Bech Kjeldsen
Rolf Bech Kjeldsen
JCJuliane Fjelrad Christfort
Juliane Fjelrad Christfort
EVEduard Marzo Vila
Eduard Marzo Vila
TATommy Sonne Alstrøm
Tommy Sonne Alstrøm
ABAnja Boisen
Anja Boisen
During the past decades, microdevices have been evaluated as a means to overcome challenges within oral drug delivery, thus improving bioavailability. Fabrication of microdevices is often limited to planar or simple 3D designs. Therefore, this work explores how microscale stereolithography 3D printing can be used to fabricate radiopaque microcontainers with enhanced mucoadhesive geometries, which can enhance bioavailability by increasing gastrointestinal retention. Ex vivo force measurements suggest increased mucoadhesion of microcontainers with adhering features, such as pillars and arrows, compared to a neutral design. In vivo studies, utilizing planar X‐ray imaging, show the time‐dependent gastrointestinal location of microcontainers, whereas computed tomography scanning and cryogenic scanning electron microscopy reveal information about their spatial dynamics and mucosal interactions, respectively. For the first time, the effect of 3D microdevice modifications on gastrointestinal retention is traced in vivo, and the applied methods provide a much‐needed approach for investigating the impact of device design on gastrointestinal retention.

20 April 2022 in HardwareX
Verified
Journal Article
Open access
TCTien-Jen Chang
Tien-Jen Chang
LNLine Hagner Nielsen
Line Hagner Nielsen
ABAnja Boisen
Anja Boisen
EHEn-Te Hwu
En-Te Hwu
In the pharmaceutical field, oral drug delivery devices continue to shrink down to the micrometer scale, driving a trending demand to investigate ex vivo mucoadhesive force down to the micro-Newton scale. However, owing to the limitation of measuring sensitivity, conventional methods (e.g., a texture analyzer) lack reliability while measuring forces in this range. Herein, we report on an open-source force analyzer that utilizes an optical-pickup-unit (from a DVD player) to detect cantilever-based force transducers and thereby, achieves a wide force-sensing range from 1.1 N to 0.99 nN. The cantilever force transducers can easily be adjusted to fit different force ranges by adjusting the steel shim, magnets, and 3D printed components. To validate the analyzer, we conducted a preliminary study to investigate the effect of time and humidity of mucoadhesion of porcine intestinal tissues. Besides, we measured the mucoadhesive force of a single oral drug delivery microdevice with an average force of 93.7 µN on the top sides of the device. This analyzer offers the possibility of measuring e.g. mucoadhesion of individual microdevices in the micro-Newton range. Hence, the analyzer can assist in the development of miniaturized oral drug delivery devices but has a much wider field of potential force sensing applications.