11 February 2020 in IEEE Sensors Journal
3 September 2021 in Journal of Physics D: Applied Physics
The single-beam miniaturized atomic magnetometer with modulated magnetic field is one of the most capable approaches to biomagnetic measurements. The transmission intensity of the pumping beam is critical to the sensitivity of the magnetometer, which is affected by the density of alkali metal and the polarization of atomic spin. In this study, we investigated into the influence of three variables: the temperature of atomic vapour; the amplitude of the modulated magnetic field; the frequency of modulated magnetic field on the transmission intensity of pumping beam. We have defined their relationship into a function, and the calculated values through theoretical analysis have a high degree of fit with the measured values of numerous experiments. It is discovered that the transmission intensity decreases with the increase in temperature, and this effect is modified by the modulation index. A compact magnetometer is developed as a proof of concept based on single-beam scheme. The volume of this magnetometer is 10 cm 3 , and its dual axis sensitivity are both 30 fT/Hz . Based on this relationship we find that two major improvements are achieved by separating the DC and AC components of transmission intensity: 1. Realizing closed-loop temperature control for atomic vapour which improved the stability of the magnetometer. 2. Achieving closed-loop dual axis magnetic measurements under a single-beam scheme, which extends the magnetometer’s scope of application.
1 January 2020 in AIP Advances
In this work, an efficient method for frequency stabilization of a highly off-resonant laser in a spin-exchange relaxation-free atomic inertial sensor is proposed. This was accomplished via the use of an optical resonator that transferred the stability of an atomic energy level to the laser frequency. The pump laser frequency was stabilized via saturation absorption spectroscopy and was used as a reference to lock the large-detuned probe laser with a double transmission Fabry–Pérot (FP) cavity. The frequency stability and bandwidth of the entire transfer cavity frequency locking system were investigated, and the results were used to elucidate the effect of cavity length on stability. The frequency stability of the system approached 1.66 × 10−11 when the FP cavity length was 30 mm. This method can be applied to a variety of ultrasensitive atomic physics experiments, such as for precision spectroscopy and laser cooling.
24 March 2021 in Measurement Science and Technology
The comprehensive influence of the amplitude and frequency of the modulated magnetic field and the magnitude of the bias magnetic field on the performance of an atomic magnetometer have been investigated. Under different magnetic fields, the combined action of the spin precession signal caused by a high-amplitude magnetic field and the influence of magnetic field on relaxation makes the time domain output signal and the amplitude of the first to fourth harmonics show different characteristics, which cannot be explained by the classical analytical calculation solution. By considering the influence of the magnetic field on the transverse relaxation, a more complete model is constructed to explain the phenomenon with a numerical solution, and the overall fit is 93.26%. Based on the single beam and magnetic field modulation scheme, a compact magnetometer is constructed for verification, with a volume of 56.7 cm 3 and a sensitivity of 30 fT/Hz 1/2 .
1 January 2022 in Review of Scientific Instruments
A single-beam spin-exchange relaxation-free atomic magnetometer is ultra-sensitive in the zero field, which has great potential for the detection of a magnetoencephalogram. The addition of a modulated magnetic field is an important approach to achieve high sensitivity for devices of this kind. In this study, we discovered that the amplitude and frequency of the modulated magnetic field (modulation index 0–3) both influence the light absorption. We defined this effect into a function by combining theoretical analysis and the results of experiments. It is discovered that the transmission intensity decreases with an increase in the modulation index. This effect is weakened under the application of a high modulation index. In addition, the transmission intensity and bias magnetic field no longer follow a strict Lorentz curve, while a high degree of fit can be achieved by applying the numerical solution of the Bloch function. A compact magnetometer with a volume of 10 cm3 and a sensitivity of 20 is developed based on the single beam scheme for the proof of concept. Our study is crucial in two aspects: (1) Obtaining high sensitivity through a short measurement period and (2) alignment of the scale factor of the individual magnetometer in a detection array, which further pave the way for improvement in a magnetometer’s performance under a variety of optics platforms.