12 March 2019 in IEEE Transactions on Applied Superconductivity
We developed a 51-channel magnetocardiography (MCG) system based on weakly damped dc superconducting quantum interference device (SQUID) magnetometers. In previous works, the system consisted of 36 sensing magnetometers, 12 reference magnetometers, and a three-component vector magnetometer. In this paper, we have describe the optimizing processes of software gradiometer configurations in different magnetically shielded rooms (MSRs). Using a simulated MCG signal generated by a small coil driven by electrocardiograph, we have quantitatively evaluated the signal quality through four key performance indices, which are (1) correlation in time domain, (2) correlation in frequency domain, (3) relative heights of different peaks, and (4) magnetic field map of simulating coil. After data processing and analysis of these four parameters, optimized software gradiometers of first or second order can be formed by using specific reference magnetometer signals to compensate the signals of 36 sensing magnetometers in each MSR. Also, the MCG signals of an adult have been detected by using these optimized configurations. The magnetic field maps and typical parameters at T-peak have been extracted and compared, and the results with high consistency confirm the effectiveness of optimization processes.
27 December 2018 in IEEE Transactions on Applied Superconductivity
Gradiometer module plays a significant role in fetal magnetocardiography (fMCG) system and its performance de-termines the signal qualities directly. In order to obtain the best signal-to-noise ratio (SNR) of the fMCG signals in a thin magnet-ically shielding room (tMSR), the baseline of the axial gradiome-ters need to be optimized. In this paper, direct current supercon-ducting quantum interference device (dc SQUID) which is com-posed of weakly damped Josephson Junctions with βc>3 and has a flux-to-voltage transfer coefficient of 500 μV/Ω0 is employed for our gradiometers. Superconducting connectivity technique is uti-lized to connect input coil and pickup coil. First-order gradiome-ters with different baselines are thus developed. After the evalua-tion of the magnetic flux density and gradient flux density inside the tMSR, measurement of fMCG signals are taken with the gra-diometers mentioned above. The simulated fetal QRS peak sig-nals about 2.5 pT could easily be identified in the real-time gra-diometer module outputs with a signal-to-noise ratio larger than 11dB.