Qing-Long Meng

Qing-Long Meng

Auto-generated profile, based on publicly available information

Qing-Long Meng

Building Energy and Environment Laboratory, School of Architecture, Guangzhou Municipal Key Laboratory of Landscape Architecture, State Key Lab of Subtropical Building Science, South China University of Technology, Guangzhou, People’s Republic of China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 July 2021 in Materials Today Physics
Verified
Journal Article
Closed access
MYM. Yuan
M. Yuan
XWX. Wan
X. Wan
QMQ. Meng
Q. Meng
XLX. Lu
X. Lu
LSL. Sun
L. Sun
XBX. Bao
X. Bao

1 December 2013 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
CLChong-Il Lee
Chong-Il Lee
QMQing-Long Meng
Qing-Long Meng
HKHiroshi Kaneko
Hiroshi Kaneko
YTYutaka Tamaura
Yutaka Tamaura

1 January 2014 in Energy Procedia
Verified
Journal Article
Open access
YTY. Tamaura
Y. Tamaura
SSS. Shigeta
S. Shigeta
QMQ.-L. Meng
Q.-L. Meng
HKH. Kikura
H. Kikura
The novel solar concentration system, Cross linear (CL) system, with which a high cosine factor above 0.85 can be achieved through the year even in winter season and at high latitudes, has been invented by Tokyo Institute of Technology. Theoretical expression of the cosine factor for CL system can be given by cosine factor = sin δ{cos ϕ (-cos μ) + sin ϕ sin μ) + cos δ cos ω(sin ϕ cos μ + cos ϕ sin μ), where δ, ϕ, μ, amd ω are solar declination, latitude, elevation angle of the reflection mirror, and hour angle, respectively. The value of tan μ corresponds to the ratio of the receiver height and mirror position distance from the receiver position for the receiver/mirror configuration of the CL concentration system. One simulation result for the CL system sample geometry (tan μ = 0.7, mirror length 1.5m, mirror number=13 in north side, and 2 in south side from the receiver) shows that we can get 7.7kWh/m2/d for each mirror (as average) in December at 36.8°N latitude and 11.5 kWh/m2/d in August, assuming DNI = 1.0kW/m2 and collection efficiency = 1.0. Nearly the same result is obtained at high latitude of 40οN latitude. Thus, a higher cosine factor above 0.85 can be obtained in winter months even at the higher northern latitude. Also, the CL system can eliminate the end loss, and a comparison study shows that CL system can significantly increase the optical efficiency compared to Trough and LFR (Linear Fresnel Reflector system). Also, from the flux values above 100kW/m2 obtained by simulation for the CL system sample, it can be expected that a higher temperature around 600-700°C can be reliably obtained and the air is heated up with a tubular receiver even in the winter season. With varying the parameters for CL system configuration, suitable solar concentration system with a high cosine factor could be designed depending on a wide temperature range of 300-700°C. A joint collaboration between Japanese and Indian industries, institutes and universities has been launched to demonstrate and develop the CL system technology in Dec 2012