Lei Zhang

Dr. Lei Zhang


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Building and Environment
Verified
Journal Article
Closed access
Junsong WangJunsong Wang
Junsong Wang
QMQinglin Meng
Qinglin Meng
LZLei Zhang
Lei Zhang
YZYu Zhang
Yu Zhang
Bao-Jie HeBao-Jie He
Bao-Jie He
Mst SantamourisMst Santamouris
Mst Santamouris

1 October 2019 in Solar Energy
Verified
Journal Article
Closed access
Junsong WangJunsong Wang
Junsong Wang
Mst SantamourisMst Santamouris
Mst Santamouris
QMQinglin Meng
Qinglin Meng
Bao-Jie HeBao-Jie He
Bao-Jie He
LZLei Zhang
Lei Zhang
YZYu Zhang
Yu Zhang


9 November 2019 in Energies
Verified
Journal Article
Open access
PDF file
YZYu Zhang
Yu Zhang
LZLei Zhang
Lei Zhang
LMLuyao Ma
Luyao Ma
QMQinglin Meng
Qinglin Meng
PRPeng Ren
Peng Ren
The present study aims to further demonstrate the cooling benefits of an extensive green roof (EGR) and fill the gap existing in the literature in terms of a sensitivity analysis of an EGR, especially in subtropical areas. First, onsite measurements were performed. The results indicated that the peak air temperatures in the chamber with the EGR were 4.0 °C and 1.9 °C lower, respectively, compared to those in the chamber with a bare roof on sunny and rainy days. Moreover, the EGR decreased the daily electricity consumption from air conditioning by up to 16.7% on sunny days and 6.7% on cloudy days. Second, the measured values were employed to validate the green roof module (GRM) in EnergyPlus. The results demonstrated that the GRM yielded accurate results in quantifying the cooling benefits of the EGR. Finally, we selected 16 factors of the EGR, each with four levels, to perform the sensitivity analysis. Range and variance analyses revealed that the factors that most significantly impacted the EGR performance were the R-value of roof construction, substrate (soil) thickness, the thermal conductivity of dry substrate, the leaf area index, leaf emissivity, and the solar absorptance of the substrate. These factors contributed 90.8% to the performance index.

13 March 2017 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
YZYu Zhang
Yu Zhang
LZLei Zhang
Lei Zhang
QMQinglin Meng
Qinglin Meng
YFYanshan Feng
Yanshan Feng
YCYuanrui Chen
Yuanrui Chen

3 March 2012 in Journal of Central South University
Verified
Journal Article
Closed access
PDF file
LZLei Zhang
Lei Zhang
QMQing-Lin Meng
Qing-Lin Meng