Luciano Melo Silva

Luciano Melo Silva

Auto-generated profile, based on publicly available information

Luciano Melo Silva

Institute of Biology, Graz University ; Institute of Botany, Ulm University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Industrial Crops and Products
Verified
Journal Article
Closed access
LCLarissa P. Cruz
Larissa P. Cruz
VPVinícius S. Pacheco
Vinícius S. Pacheco
LSLuciano M. Silva
Luciano M. Silva
RARafael Leonardo de Almeida
Rafael Leonardo de Almeida
MMMarcela T. Miranda
Marcela T. Miranda
RRRafael V Ribeiro
Rafael V Ribeiro

10 September 2023 in New Phytologist
Verified
Journal Article
Open access
LPLuciano Pereira
Luciano Pereira
LKLucian Kaack
Lucian Kaack
XGXinyi Guan
Xinyi Guan
LSLuciano de Melo Silva
Luciano de Melo Silva
MMMarcela T. Miranda
Marcela T. Miranda
SJSteven Jansen
Steven Jansen
Summary: Intervessel pits are considered to function as valves that avoid embolism spreading and optimize efficient transport of xylem sap across neighbouring vessels. Hydraulic transport between vessels would therefore follow a safety‐efficiency trade‐off, which is directly related to the total intervessel pit area (Ap), inversely related to the pit membrane thickness (TPM) and driven by a pressure difference. To test this hypothesis, we modelled the relative transport rate of gas (ka) and water (Q) at the intervessel pit level for 23 angiosperm species and correlated these parameters with the water potential at which 50% of embolism occurs (Ψ50). We also measured ka for 10 species using pneumatic measurements. The pressure difference across adjacent vessels and estimated values of ka and Q were related to Ψ50, following a convex safety‐efficiency trade‐off based on modelled and experimental data. Minor changes in TPM and Ap exponentially affected the pressure difference and flow, respectively. Our results provide clear evidence that a xylem safety‐efficiency trade‐off is not linear, but convex due to flow across intervessel pit membranes, which represent mesoporous media within microporous conduits. Moreover, the convex nature of long‐distance xylem transport may contribute to an adjustable fluid balance of plants, depending on environmental conditions.

20 April 2022 in Theoretical and Experimental Plant Physiology
Verified
Journal Article
Closed access
PDF file
LSLuciano M. Silva
Luciano M. Silva
LCLarissa P. Cruz
Larissa P. Cruz
VPVinícius S. Pacheco
Vinícius S. Pacheco
EMEduardo C. Machado
Eduardo C. Machado
LPLuis Felipe Villani Purquerio
Luis Felipe Villani Purquerio
RRRafael V Ribeiro
Rafael V Ribeiro

9 August 2024 in Plant, Cell & Environment
Verified
Journal Article
Open access
LSLuciano M. Silva
Luciano M. Silva
LPLuciano Pereira
Luciano Pereira
LKLucian Kaack
Lucian Kaack
XGXinyi Guan
Xinyi Guan
JPJonas Pfaff
Jonas Pfaff
SJSteven Jansen
Steven Jansen
Understanding xylem embolism formation is challenging due to dynamic changes and multiphase interactions in conduits. Here, we hypothesise that embolism spread involves gas diffusion in xylem, and is affected by time. We measured hydraulic conductivity (Kh) in flow‐centrifuge experiments over 1 h at a given pressure and temperature for stem samples of three angiosperm species. Temporal changes in Kh at 5, 22, and 35°C, and at various pressures were compared to modelled gas concentration changes in a recently embolised vessel in the centre of a centrifuge sample. Temporal changes in Kh were logarithmic and species‐specific. Maximum relative increases of Kh between 6% and 40% happened at 22°C for low centrifugal speed (<3250 RPM), while maximum decreases between 41% and 61% occurred at higher speeds. These reductions in Kh were experimentally shown to be associated with a temporal increase of embolism at the centre of centrifuge samples, which was likely associated with gas concentration increases in recently embolized vessels. Although embolism is mostly pressure‐driven, our experimental and modelled data indicate that time, conduit characteristics, and temperature are involved due to their potential role in gas diffusion. Gas diffusion, however, does not seem to cover the entire process of embolism spread.

10 October 2024 in Tree Physiology
Verified
Journal Article
Closed access
PDF file
LSLuciano M Silva
Luciano M Silva
JPJonas Pfaff
Jonas Pfaff
LPLuciano Pereira
Luciano Pereira
MMMarcela T Miranda
Marcela T Miranda
SJSteven Jansen
Steven Jansen
Centrifuges provide a fast approach to quantify embolism resistance of xylem in vulnerability curves (VCs). Since embolism formation is assumingly driven by pressure only, spin time is not standardised for flow centrifuge experiments. Here, we explore to what extent embolism resistance could be spin-time dependent, and hypothesise that changes in hydraulic conductivity (Kh) would shift VCs towards higher water potential (Ψ) values over time. We quantified time-based shifts in flow-centrifuge VCs and their parameter estimations for six angiosperm species by measuring Kh over 15 minutes of spinning at a particular speed, before a higher speed was applied to the same sample. We compared various VCs per sample based on cumulative spin time, and modelled the relationship between Kh, Ψ, and spin-time. Time-based changes of Kh showed considerable increases and decreases at low and high centrifuge speeds, respectively, which generally shifted VCs towards more positive Ψ values. Values corresponding to 50% loss of hydraulic conductivity (P50) became less negative by up to 0.72 MPa in Acer pseudoplatanus, and on average by 8.5% for all six species compared to VCs that did not consider spin-time. By employing an asymptotic exponential model, we estimated time-stable Kh, which improved the statistical significance of VCs in 5 of the 6 species studied. This model also revealed the instability of VCs at short spin times with embolism formation in flow-centrifuges following a saturating exponential growth curve. Although pressure remains the major determinant of embolism formation, spin-time should be considered in flow-centrifuge VCs because not considering the time-dependent stability of Kh overestimates embolism resistance. This spin-time artefact is species-specific, and likely based on relatively slow gas diffusion that is associated with embolism propagation. The accuracy of VCs is improved by determining time-stable Kh values for each centrifuge speed, without considerably extending the experimental time to construct VCs.

19 April 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
LSLuciano Melo Silva
Luciano Melo Silva
LPLuciano Pereira
Luciano Pereira
LKLucian Kaack
Lucian Kaack
XGXinyi Guan
Xinyi Guan
CTChristophe Lionel Trabi
Christophe Lionel Trabi
SJSteven Jansen
Steven Jansen
Understanding xylem embolism formation is challenging due to dynamic changes and multiphase interactions in conduits. If embolism spread involves gas movement in xylem, we hypothesise that it is affected by time. We measured hydraulic conductivity (K h ) in flow-centrifuge experiments over one hour at a given pressure and temperature for stem samples of three angiosperm species. Temporal changes in K h at 5, 22, and 35°C, and at various pressures were compared to modelled gas pressure changes in a recently embolised vessel in the centre of a centrifuge sample. Temporal changes in K h at 22°C showed maximum relative increases between 6% and 40%, and maximum decreases between 41% and 61% at low and high centrifugal speed, respectively. Logarithmic changes in K h were species-specific, and most pronounced during the first 15 minutes. Embolism formation started near the edges of centrifuge samples and gradually increased at the centre. Moreover, measured decreases in K h strongly correlated with modelled increases in gas concentration in a recently embolised vessel. Although embolism is mostly pressure-driven, our experimental and modelled data indicate that time, conduit characteristics, and temperature are involved due to their role in gas diffusion. Gas diffusion, however, does not cover the entire process of embolism spread.