Yunjie Wang

Yunjie Wang

Auto-generated profile, based on publicly available information

Yunjie Wang

CAS Key Laboratory of Urban Pollutant Conversion, Department of Environmental Science and Engineering, University of Science & Technology of China, Hefei, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
YMYan Meng
Yan Meng
YLYu-Qin Liu
Yu-Qin Liu
CWChao Wang
Chao Wang
YSYang Si
Yang Si
YWYun-Jie Wang
Yun-Jie Wang
WLWen-Wei Li
Wen-Wei Li
The introduction of single-atom catalysts (SACs) into Fenton-like oxidation promises ultrafast water pollutant elimination, but the limited access to pollutants and oxidant by surface catalytic sites and the intensive oxidant consumption still severely restrict the decontamination performance. While nanoconfinement of SACs allows drastically enhanced decontamination reaction kinetics, the detailed regulatory mechanisms remain elusive. Here, we unveil that, apart from local enrichment of reactants, the catalytic pathway shift is also an important cause for the reactivity enhancement of nanoconfined SACs. The surface electronic structure of cobalt site is altered by confining it within the nanopores of mesostructured silica particles, which triggers a fundamental transition from singlet oxygen to electron transfer pathway for 4-chlorophenol oxidation. The changed pathway and accelerated interfacial mass transfer render the nanoconfined system up to 34.7-fold higher pollutant degradation rate and drastically raised peroxymonosulfate utilization efficiency (from 61.8% to 96.6%) relative to the unconfined control. It also demonstrates superior reactivity for the degradation of other electron-rich phenolic compounds, good environment robustness, and high stability for treating real lake water. Our findings deepen the knowledge of nanoconfined catalysis and may inspire innovations in low-carbon water purification technologies and other heterogeneous catalytic applications.

13 May 2022 in ACS Nano
Verified
Journal Article
Closed access
YPYubing Peng
Yubing Peng
XWXian Wei
Xian Wei
YWYunjie Wang
Yunjie Wang
WLWenwei Li
Wenwei Li
SZShenxiang Zhang
Shenxiang Zhang
JJJian Jin
Jian Jin

22 December 2023 in Water Research
Verified
Journal Article
Closed access
YWYun-Jie Wang
Yun-Jie Wang
CLChen-Xuan Li
Chen-Xuan Li
YMYan Meng
Yan Meng
ZGZhi-Yan Guo
Zhi-Yan Guo
SCShuo Cui
Shuo Cui
WLWen-Wei Li
Wen-Wei Li

29 December 2023 in ACS ES&T Water
Verified
Journal Article
Closed access
ZHZhenyu Hu
Zhenyu Hu
TLTian Liu
Tian Liu
YWYunjie Wang
Yunjie Wang
JWJianyu Wu
Jianyu Wu
MFMuhammad Usman Farid
Muhammad Usman Farid
WLWen-Wei Li
Wen-Wei Li

12 December 2019 in International Journal of Energy Research
Verified
Journal Article
Open access
PDF file
Haifei ChenHaifei Chen
Haifei Chen
GGuiqiang Li
Guiqiang Li
YWYunjie Wang
Yunjie Wang
FZFuwei Zhang
Fuwei Zhang
Ali BadieiAli Badiei
Ali Badiei
YZYang Zhang
Yang Zhang
This thesis investigates a novel solar‐assisted heat pump integrated phase change energy storage system. The defrosting performance of this system was studied experimentally and the results were compared with two traditionally used methods: reverse cycle defrosting (RCD) method and hot gas bypass defrosting (HGBD) method. The results show that the phase change energy storage system has superior performance compared with traditional defrosting methods. The indoor temperature drop recorded was relatively small and the defrosting time was 75% of the RCD system and 53% of HGBD system. The phase change energy storage system increased the condensation temperature which consequently increased the temperature difference of heat transfer resulting in higher conductivity in the defrosting progress. Compared with the method of RCD and the method of HGBD, the recovery time of the system was shortened by 90 and 160 seconds, respectively. The system works with low‐temperature heat source and circulating water, which considerably reduces energy consumption, thereby improving the performance of the defrosting system. A further experimental study was also conducted on the heating performance and the results also indicated that the value of COP can reach up to 3.6 in daytime, and the indoor temperature can be stably maintained above 18°C throughout the day. Novelty Statement A new defrosting method for energy storage defrosting is proposed, and the defrosting performance is compared with two common defrosting methods. In addition, the performances of the heating system over the day were experimentally investigated. The experimental results show the system meets the heating needs of the building. Finally, the influence of the outdoor temperature on the exergy efficiency of the system was discussed. It shows that this system can improve the operational stability, the system economy and energy saving.

18 July 2023 in ACS ES&T Engineering
Verified
Journal Article
Closed access
ZWZhenyu Wang
Zhenyu Wang
YSYang Si
Yang Si
YWYunjie Wang
Yunjie Wang
TLTian Liu
Tian Liu
MGMiao Gao
Miao Gao
WLWenwei Li
Wenwei Li