Manimaran Govindarasu

Manimaran Govindarasu

Auto-generated profile, based on publicly available information

Manimaran Govindarasu

Iowa State University

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2007 in 2007 IEEE Power Engineering Society General Meeting
Verified
Conference Paper
Closed access
CTChee-Wooi Ten
Chee-Wooi Ten
CLChen-Ching Liu
Chen-Ching Liu
MGManimaran Govindarasu
Manimaran Govindarasu
By penetrating the SCADA system, an intruder may remotely operate a power system using supervisory control privileges. Hence, cybersecurity has been recognized as a major threat due to the potential intrusion to the online system. This paper proposes a methodology to evaluate the cybersecurity vulnerability using attack trees. The attack tree formulation based on power system control networks is used to evaluate the system, scenario, and leaf vulnerabilities. The measure of vulnerabilities in the power system control framework is determined based on existing cybersecurity conditions before the vulnerability indices are evaluated. After the indices are evaluated, an upper bound is imposed on each scenario vulnerability in order to determine the pivotal attack leaves that require countermeasure improvements. The proposed framework can be extended to security investment analysis.

1 September 2016
Verified
Conference Paper
Closed access
AAAditya Ashok
Aditya Ashok
SKSujatha Krishnaswamy
Sujatha Krishnaswamy
MGManimaran Govindarasu
Manimaran Govindarasu
Cyber Physical Systems (CPS) security testbeds serve as a platform for evaluating and validating novel CPS security tools and technologies, accelerating the transition of state-of-the-art research to industrial practice. The engineering of CPS security testbeds requires significant investments in money, time and modeling efforts to provide a scalable, high-fidelity, real-time attack-defense platform. Therefore, there is a strong need in academia and industry to create remotely accessible testbeds that support a range of use-cases pertaining to CPS security of the grid, including vulnerability assessments, impact analysis, product testing, attack-defense exercises, and operator training. This paper describes the implementation architecture, and capabilities of a remote access and experimental orchestration framework developed for the PowerCyber CPS security testbed at Iowa State University (ISU). The paper then describes several engineering challenges in the development of such remotely accessible testbeds for Smart Grid CPS security experimentation. Finally, the paper provides a brief case study with some screenshots showing a particular use case scenario on the remote access framework.

13 August 2015 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Open access
PDF file
Jie YanJie Yan
Jie Yan
MGManimaran Govindarasu
Manimaran Govindarasu
CLChen-Ching Liu
Chen-Ching Liu
MNMing NI
Ming NI
UVUmesh Vaidya
Umesh Vaidya
Cyber threats are serious concerns for power systems. For example, hackers may attack power control systems via interconnected enterprise networks. This paper proposes a risk assessment framework to enhance the resilience of power systems against cyber attacks. The duality element relative fuzzy evaluation method is employed to evaluate identified security vulnerabilities within cyber systems of power systems quantitatively. The attack graph is used to identify possible intrusion scenarios that exploit multiple vulnerabilities. An intrusion response system (IRS) is developed to monitor the impact of intrusion scenarios on power system dynamics in real time. IRS calculates the conditional Lyapunov exponents (CLEs) on line based on the phasor measurement unit data. Power system stability is predicted through the values of CLEs. Control actions based on CLEs will be suggested if power system instability is likely to happen. A generic wind farm control system is used for case study. The effectiveness of IRS is illustrated with the IEEE 39 bus system model.

19 October 2020
Verified
Conference Paper
Closed access
GRGelli Ravikumar
Gelli Ravikumar
ASAbhinav K Singh
Abhinav K Singh
JBJeyanth Rajan Babu
Jeyanth Rajan Babu
AAAbdelkhalek Moataz A
Abdelkhalek Moataz A
MGManimaran Govindarasu
Manimaran Govindarasu
Increasing penetration of distributed energy resources (DERs) in distribution networks expands the cyberattack surface. Moreover, the widely used standard protocols for communicating DER inverters such as Modbus is more vulnerable to data-integrity attacks and denial of service (DoS) attacks because of its native clear-text packet format. This paper proposes a distributed intrusion detection system (D-IDS) architecture and algorithms for detecting anomalies on the DER Modbus communication. We devised a model-based approach to define physics-based threshold bands for analog data points and transaction-based threshold bands for both the analog and discrete data points. The proposed IDS algorithm uses the model- based approach to develop Modbus-specific IDS rule sets, which can enhance the detection accuracy of the anomalies either by data-integrity attacks or maloperation on cyber-physical DER Modbus devices. Further, the IDS algorithm autogenerates the Modbus-specific IDS rulesets in compliance with various open- source IDS rule syntax formats, such as Snort and Suricata, for seamless integration and mitigation of semantic/syntax errors in the development and production environment. We considered the IEEE 13-bus distribution grid, including DERs, as a case study. We conducted various DoS type attacks and data-integrity attacks on the hardware-in-the-loop (HIL) CPS DER testbed at ISU to evaluate the proposed D-IDS. Consequently, we computed the performance metrics such as IDS detection accuracy, IDS detection rate, and end-to-end latency. The results demonstrated that 100% detection accuracy, 100% detection rate for 60k DoS packets, 99.96% detection rate for 80k DoS packets, and 0.25 ms end-to-end latency between DERs to Control Center.

27 July 2022
Verified
Conference Paper
Closed access
SPShaurya Purohit
Shaurya Purohit
MGManimaran Govindarasu
Manimaran Govindarasu
With advancements in the automotive industry and self-driving cars, automotive cybersecurity has become a pivotal and prioritized issue for all automakers. The CAN-bus is widely used to exchange data between vehicular networks and components, such as safety-critical systems and infotainment. Despite its importance, CAN bus systems lack security safeguards, exposing them to various security threats. This work proposes a novel two-stage Anomaly Detection System that detects malicious attacks with high detection accuracy incurring low latency. The novelty of this work is to use machine learning techniques like Decision Tree, Random Forest, and XGBoost to get predictable results while balancing with rule-based systems and keeping computational effort low. The experimental results demonstrate that our proposed model can detect different attacks with high accuracy (above 90%) on the CAN-intrusion-dataset with very low execution time and high F1-score. Thus, proving the effectiveness and efficiency of our hybrid model.

29 November 2011
Verified
Book Chapter
Closed access
PDF file
SSSiddharth Sridhar
Siddharth Sridhar
MGManimaran Govindarasu
Manimaran Govindarasu
CLChen-Ching Liu
Chen-Ching Liu