1 March 2022 in Journal of Renewable and Sustainable Energy
The molten-salt heat exchanger is a critical heat transfer device used in concentrated solar power systems. In this paper, molten salt heat-transfer performance characteristics and flow resistances in shell and tube heat exchangers with perforated baffles with a notch height of 0.25D (D is the baffle diameter) are simulated. Four opening schemes that use the same opening area (10% of the baffle area) are designed. The numerical results show that the baffle holes can shrink the molten salt flow dead zone significantly and greatly decrease the flow resistance on the shell side at the cost of a slight reduction in the heat-transfer performance. The comprehensive performance of each scheme after opening is higher than that before opening, and the comprehensive performance of Scheme 4 is the best. Next, a genetic algorithm is used to optimize the Scheme 4 opening diameter. The results show that the heat-flux density on the molten-salt side reaches a maximum of 17327 W/m2 when the opening diameter is 2.24 mm. We find that the opening diameter should be maximized to optimize the comprehensive performance at a given pump power. Finally, the data are compared to other correlations. The deviation decreases gradually as the Reynolds number increases. This is because the turbulence enhancement caused by structural change is not substantial at high Reynolds numbers.
1 January 2017 in Atomization and Sprays
Axisymmetric computational fluid dynamics (CFD) simulations are conducted to investigate the deformation and breakup of water drops in an air stream at different Weber numbers. The type of flows considered lie in the oscillatory, the bag breakup, the stamen breakup, and the stripping breakup regimes. A fully three-dimensional simulation is first performed to justify the axisymmetry assumption used in the remaining CFD simulations. In order to keep the drop within the fixed computational domain, the shifted Eulerian adaption (SEA) method has been developed. In this method all the field values are shifted back by one mesh cell after the center of the liquid mass has moved forward by one cell, while at the same time the boundary conditions are maintained. The CFD results are compared with experimental drop breakup observations, and are used to validate a proposed modification to the Taylor analogy breakup (TAB) model. The modifications to the original TAB model account for the nonlinear change of the drop cross section and the associated change in the drag coefficient. The validations include the critical deformation at which the drop starts disintegrating, the drop oscillation periods, as well as the normalized drop deformation at the initiation time for breakup. The CFD results show good agreement with the modified TAB model, and the breakup behavior qualitatively reflects experimental observations.
1 November 2023 in Journal of Renewable and Sustainable Energy
Addressing the issue of flow dead zones in molten salt heat exchangers in concentrating solar power generation systems, this study focuses on the conventional shell and tube heat exchanger using molten salt and heat transfer oil as the working medium. The flow dynamics of molten salt within the heat exchanger are analyzed. To quantify the volume fraction of the molten salt flow dead zones, the residence time distribution curve is employed. Four baffle salt flow configurations are comparatively assessed. Findings indicate that the four opening configurations effectively enhance the reduction of molten salt flow dead zones, with volume fraction reductions ranging from 57.8% to 68.21%. Notably, configuration 4 yields the most optimal results. Furthermore, molten salt flow states in varying regions were examined: the innermost flow dead zone exhibited the highest improvement, followed by the middle area, with the edge area showing the least enhancement. Additionally, the impact of the opening diameter on the flow dead zone was explored. The volume fraction of the molten salt flow dead zone diminishes as the opening diameter expands, with the rate of this change also decelerating. Given that molten salt at the opening manifests as a jet, enlarging the opening diameter lessens the pressure differential across the baffle, subsequently weakening the jet's intensity and its influence on the flow dead zone.