Xi-Xin Wang

Xi-Xin Wang

Auto-generated profile, based on publicly available information

Xi-Xin Wang

College of Information Science and Engineering, Northeastern University, Shenyang, China

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YZYong Zhao
Yong Zhao
XWXi-Xin Wang
Xi-Xin Wang
RLRi-Qing Lv
Ri-Qing Lv
GLGui-Lin Li
Gui-Lin Li
HZHong-Kun Zheng
Hong-Kun Zheng
YZYi-Fan Zhou
Yi-Fan Zhou
A highly sensitive reflective Fabry-Perot (FP) magnetic field sensor using magnetic fluid (MF) based on Vernier effect is presented and experimentally verified. Capillary action acts as an injection of MF into a FP cavity, which is composed of a single mode fiber (SMF), capillary glass tube and a short section of SMF coated with gold film. Vernier effect is formed by MF cavity and air cavity in the FP magnetic field sensor, where the surface of MF is concave. The refractive index (RI) of MF depends on magnetic field, so wavelength of reflection spectrum of the fabricated sensor can be sensitive to magnetic field. The magnetic field sensor’s sensitivity is up to 1.02602 nm/Gs from 118.768 to 166.261 Gs and the resolution is 0.0078 Gs. The sensor shows a good linearity within the range of 71.317-231.751 Gs, and the linearity is larger than 0.999. In this paper, a new type FP cavity fabricated by splicing SMF inside capillary glass tube is proposed, and MF can be injected into the FP cavity, which can also be applied to other liquids to generate Vernier effect. The concave surface of magnetic fluid is creatively applied to the sensors and the experimental verification is carried out in capillary glass tube, which provides a basis on capillary action of other fluids in fiber sensing.

27 October 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HZHong-Kun Zheng
Hong-Kun Zheng
Yong ZhaoYong Zhao
Yong Zhao
RLRiqing Lv
Riqing Lv
ZLZi-Ting Lin
Zi-Ting Lin
XWXi-Xin Wang
Xi-Xin Wang
SCshizhe Chen
shizhe Chen
A reflective optical fiber sensor that is composed of two Fabry Perot cavities is proposed for temperature and salinity measurement. One of the Fabry Perot cavity which is fabricated by offset splicing is exposed to the ambient directly to sense the ambient salinity, the other is employed to compensate for the temperature coupling effect. A thin layer of the gold film is coated on the refractive index change interface, which makes the spectrum quality is no longer limited by the refractive index difference between the two sides of the interface. By applying the frequency division multiplexing (FDM) technique and cavity length demodulation technology, the measurement range is no longer restricted to the free spectrum range (FSR), which can realize salinity measurement in the full measurement range. The proposed sensor can realize the salinity sensitivity better than 50 nm/‰ and temperature sensitivity of 6.85 nm/°C in the cavity length domain. It is promising for salinity measurement application for its merits of low cost, easy fabrication, and long sensing distance.

24 March 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Yong ZhaoYong Zhao
Yong Zhao
XWXi-Xin Wang
Xi-Xin Wang
RLRiqing Lv
Riqing Lv
HZHong-Kun Zheng
Hong-Kun Zheng
YZYi-Fan Zhou
Yi-Fan Zhou
MCMaoqing chen
Maoqing chen
A magnetic field measurement method based on the magneto-volume effect of magnetic fluid (MF) and Fabry-Perot (FP) interferometer (FPI) is proposed, which has higher magnetic field sensitivity and shorter response time than the traditional optical fiber methods. The MF is partially injected into the fabricated FP cavity composed of two sections of SMFs and a capillary glass tube (CGT), where the FPI is made up of optical fiber end face and MF end face. When the external magnetic field is applied to the sensor, the volume change of MF will cause the change of air cavity length. Therefore, the reflection spectrum changes with external magnetic field due to the magneto-volume effect of MF. Experimental results show that the magnetic field sensor shows a sensitivity of 268.81 pm/Gs from 15.5 to 139.7 Gs even with a small amount of MF. The response time is 0.2 s at a step magnetic field of 7.7, 31.0, 46.5, and 139.7 Gs. In this work, the magnetic field sensor boasts high sensitivity, good repeatability, short response time, and low cost, which shows a great potential in applications.

23 September 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XWXi-Xin Wang
Xi-Xin Wang
Yong ZhaoYong Zhao
Yong Zhao
RLRiqing Lv
Riqing Lv
HZHong-Kun Zheng
Hong-Kun Zheng
CLCai Lu
Cai Lu
A novel magnetic field measurement method based on the magneto-volume effect is proposed. The magnetic field sensing structure fabricated by the proposed measurement method is made by the magnetic fluid (MF) partially filled into the hollow core fiber (HCF). The presence of air provides conditions for the change of MF volume with the magnetic field in the proposed sensing structure. Therefore, the magneto-volume effect is introduced into the magnetic field sensing mechanism. From 109.6 to 125.8 Gs, the peak wavelength shift is −65480 pm and the sensitivity is −4219.15 pm/Gs, which is 28.16 times higher than that of the fabricated contrast sensing structure. The sensitivity of the magnetic field sensing structure is greatly improved by introducing the magneto-volume effect compared with the contrast sensing structure. The response time and recovery time of the sensing structure are equally 0.2 s. Therefore, the sensing structure has high sensitivity, good linearity, and short response time, which has potential application prospects in magnetic field sensing.

2 November 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HZHong-Kun Zheng
Hong-Kun Zheng
Yong ZhaoYong Zhao
Yong Zhao
RLRiqing Lv
Riqing Lv
ZLZi-Ting Lin
Zi-Ting Lin
XWXi-Xin Wang
Xi-Xin Wang
XHXu-Guang Hu
Xu-Guang Hu
In this article, a reflective-type optical fiber probe, which can measure salinity and temperature simultaneously, is proposed. The proposed probe integrates Mach–Zehnder interferometer and Fabry–Perot interferometer in the same channel skillfully and effectively, which makes it possible to integrate more information into the sensor. The reflected spectrum is improved greatly by adopting special sputtering technology. The spectrums of Mach–Zehnder and Fabry–Perot are separated by applying the frequency division multiplex technique. The simulation and experimental results prove that the proposed probe has a highly sensitive response to temperature and salinity. The experiment result verifies that the salinity sensitivity is up to 2.7 nm/‰ and the temperature sensitivity is better than 0.4 nm/°C. The reflective probe makes the sensor easy to use and paves the way for practical application.

14 June 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZLZi-Ting Lin
Zi-Ting Lin
Yong ZhaoYong Zhao
Yong Zhao
RLRiqing Lv
Riqing Lv
HZHong-Kun Zheng
Hong-Kun Zheng
XWXi-Xin Wang
Xi-Xin Wang
For the purpose of monitoring seawater temperature, a novel Mach-Zehnder (MZ) temperature-sensing structure with a wedge-shaped open cavity is presented and experimentally studied in this article. The open-cavity structure realizes the direct contact between the sensing optical path and the external environment, and ensures the high sensitivity of the structure. At the same time, it achieves not only low loss by direct fusion splicing instead of dislocation fusion splicing, but also low cost by hydrofluoric (HF) etching instead of femtosecond processing. In addition, the temperature sensitivity of the sensor structure proposed in this article can reach 1.5 nm/°C without temperature-sensitive material filled, and 6 nm/°C with silicone oil filled. Moreover, the resolution of the sensing structure is 0.24 °C based on the criterion of 3σ.