A highly sensitive reflective Fabry-Perot (FP) magnetic field sensor using magnetic fluid (MF) based on Vernier effect is presented and experimentally verified. Capillary action acts as an injection of MF into a FP cavity, which is composed of a single mode fiber (SMF), capillary glass tube and a short section of SMF coated with gold film. Vernier effect is formed by MF cavity and air cavity in the FP magnetic field sensor, where the surface of MF is concave. The refractive index (RI) of MF depends on magnetic field, so wavelength of reflection spectrum of the fabricated sensor can be sensitive to magnetic field. The magnetic field sensor’s sensitivity is up to 1.02602 nm/Gs from 118.768 to 166.261 Gs and the resolution is 0.0078 Gs. The sensor shows a good linearity within the range of 71.317-231.751 Gs, and the linearity is larger than 0.999. In this paper, a new type FP cavity fabricated by splicing SMF inside capillary glass tube is proposed, and MF can be injected into the FP cavity, which can also be applied to other liquids to generate Vernier effect. The concave surface of magnetic fluid is creatively applied to the sensors and the experimental verification is carried out in capillary glass tube, which provides a basis on capillary action of other fluids in fiber sensing.
A reflective optical fiber sensor that is composed of two Fabry Perot cavities is proposed for temperature and salinity measurement. One of the Fabry Perot cavity which is fabricated by offset splicing is exposed to the ambient directly to sense the ambient salinity, the other is employed to compensate for the temperature coupling effect. A thin layer of the gold film is coated on the refractive index change interface, which makes the spectrum quality is no longer limited by the refractive index difference between the two sides of the interface. By applying the frequency division multiplexing (FDM) technique and cavity length demodulation technology, the measurement range is no longer restricted to the free spectrum range (FSR), which can realize salinity measurement in the full measurement range. The proposed sensor can realize the salinity sensitivity better than 50 nm/‰ and temperature sensitivity of 6.85 nm/°C in the cavity length domain. It is promising for salinity measurement application for its merits of low cost, easy fabrication, and long sensing distance.
24 March 2021 in IEEE Transactions on Instrumentation and Measurement
A magnetic field measurement method based on the magneto-volume effect of magnetic fluid (MF) and Fabry-Perot (FP) interferometer (FPI) is proposed, which has higher magnetic field sensitivity and shorter response time than the traditional optical fiber methods. The MF is partially injected into the fabricated FP cavity composed of two sections of SMFs and a capillary glass tube (CGT), where the FPI is made up of optical fiber end face and MF end face. When the external magnetic field is applied to the sensor, the volume change of MF will cause the change of air cavity length. Therefore, the reflection spectrum changes with external magnetic field due to the magneto-volume effect of MF. Experimental results show that the magnetic field sensor shows a sensitivity of 268.81 pm/Gs from 15.5 to 139.7 Gs even with a small amount of MF. The response time is 0.2 s at a step magnetic field of 7.7, 31.0, 46.5, and 139.7 Gs. In this work, the magnetic field sensor boasts high sensitivity, good repeatability, short response time, and low cost, which shows a great potential in applications.
Optical fiber sensors have emerged as vital tools in various applications. Among them, Fabry-Perot interferometers (FPIs), have gained prominence due to their compactness and versatility in sensor design. Microwave photonics (MWP) techniques offer enhanced performance and flexibility for developing optical sensor interrogation methods. This paper proposes and experimentally demonstrates a novel MWP interrogation technique based on phase measurement for short-cavity FPI sensors. The technique utilizes the phase response of the FPI sensor within an MWP-assisted single radio frequency bandpass filter, providing improved sensitivity and dynamic sensing capabilities compared to traditional methods. Simulation and experimental results validate the effectiveness of the proposed technique in measuring both static and dynamic strains. The high sensitivity of the system, surpassing 0.00217 rad/μϵ, enables achieving a high resolution better than 100 nϵ at an operating frequency of 247.0 MHz. Additionally, the feasibility of using the technique for interrogating multiplexed FPIs with different cavity lengths is explored, showing promising results for future sensor development.
14 June 2021 in IEEE Transactions on Instrumentation and Measurement
For the purpose of monitoring seawater temperature, a novel Mach-Zehnder (MZ) temperature-sensing structure with a wedge-shaped open cavity is presented and experimentally studied in this article. The open-cavity structure realizes the direct contact between the sensing optical path and the external environment, and ensures the high sensitivity of the structure. At the same time, it achieves not only low loss by direct fusion splicing instead of dislocation fusion splicing, but also low cost by hydrofluoric (HF) etching instead of femtosecond processing. In addition, the temperature sensitivity of the sensor structure proposed in this article can reach 1.5 nm/°C without temperature-sensitive material filled, and 6 nm/°C with silicone oil filled. Moreover, the resolution of the sensing structure is 0.24 °C based on the criterion of 3σ.