Ufuk Adali

Ufuk Adali

Auto-generated profile, based on publicly available information

Ufuk Adali

Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2024 in Dental Materials
Verified
Journal Article
Open access
UAUfuk Adali
Ufuk Adali
MSMona Sütel
Mona Sütel
JYJamila Yassine
Jamila Yassine
ZMZhen Mao
Zhen Mao
Wolf-Dieter MuellerWolf-Dieter Mueller
Wolf-Dieter Mueller
ASAndreas Schwitalla
Andreas Schwitalla
Achieving a strong bond between Polyetheretherketone (PEEK) and veneering composites is challenging due to PEEKs low surface energy. This study examined the effects of sandblasting and bonding on the shear bond strength (SBS) between veneering composite and pigmented PEEK, considering artificial aging. Of three pigmented PEEK compounds (DC4420R, DC4450R, DC4470R; Evonic Operations GmbH, Marl, Germany), 40 specimens each were milled and polished up to 2500 grit. Prior to veneering, specimens were divided into 4 subgroups: Subgroup 1: Polishing; 2: Polishing + bonding; 3: Sandblasting; 4: Sandblasting + bonding. Sandblasting was performed using Al2O3. Adhesive was an agent containing MMA (Signum Universal Bond, Kulzer GmbH, Hanau, Germany). After veneering (Composite, Kulzer GmbH) the subgroups were divided into 2 subgroups. One subgroup was immersed in 37 °C warm distilled water for 24 h. The second subgroup was artificially aged by thermocycling (TCL) with 5000 cycles in distilled water (5 °C / 55 °C; 30 s). Surface roughness, water contact angles and failure modes were recorded. SBS was measured using a universal testing machine. Results demonstrated that the combination of sandblasting and bonding significantly improved the SBS compared to polishing alone. PEEK color did not significantly influence the SBS. Aging by TCL had a negative effect on the SBS. Sandblasting and the use of an adhesive containing MMA were found to be effective in achieving satisfactory SBS between veneering composite and pigmented PEEK surfaces. These pretreatment methods demonstrate their potential for establishing durable and reliable bonding in clinical applications.

26 May 2025 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
VHVera Malina Hupe
Vera Malina Hupe
FBFlorian Beuer
Florian Beuer
GSGuido Sterzenbach
Guido Sterzenbach
UAUfuk Adali
Ufuk Adali
Long-span fixed dental prostheses (FDPs) can be challenging to fabricate with adequate marginal and internal fit. The performance of restorations fabricated from cobalt chromium or zirconia using a completely digital workflow requires further evaluation to ensure clinical acceptability. The purpose of this in vitro study was to evaluate and compare the marginal and internal fit of 10-unit FDPs fabricated from cobalt chromium or zirconia by using digital scanning and computer-aided design and computer-aided manufacturing (CAD-CAM). Twenty-four complete arch digital scans of a typodont model with 6 prepared teeth were acquired to design and mill 12 cobalt chromium and 12 zirconia 10-unit FDP frameworks. For each framework, measurements from all 6 abutments and from both buccolingual and mesiodistal sections were pooled, yielding 1 mean value per measurement area per specimen. Marginal, chamfer, internal, and overall cement gaps were evaluated with the silicone replica technique. Trueness was defined as the difference between the measured gap and the preset cement spacer. Data were analyzed with 2-sample t tests on the pooled specimen means (α=.05). Mean gap measurements for cobalt chromium versus zirconia were (gap value ±standard deviation) as follows: marginal, 68.7 ±14.6 µm versus 53.3 ±11.8 µm; chamfer, 66.8 ±10.6 µm versus 58.1 ±10.8 µm; internal, 77.7 ±6.5 µm versus 95.8 ±9.4 µm; and overall cement gap, 74.2 ±8.2 µm versus 81.3 ±9.7 µm. The zirconia restorations exhibited a significantly smaller marginal gap (P=.01), whereas the cobalt chromium frameworks showed a significantly smaller internal gap (P<.001), with the chamfer gap being statistically similar (P=.061). Zirconia demonstrated significantly higher trueness in the marginal area (P=.01), while the internal gap trueness did not differ significantly between the 2 materials (difference 1.9 µm, P=.56). Both materials remained below the 120 µm clinical threshold for acceptable fit. A digital workflow yielded precise, clinically acceptable fit for 10-unit restorations fabricated from both cobalt chromium and zirconia. Zirconia demonstrated significantly higher marginal trueness, whereas the internal gap trueness did not differ significantly between the 2 materials. Optimizing cement spacer settings and evaluating deviations from the planned spacer are crucial for an accurate assessment of fit.

18 February 2025 in TURKISH JOURNAL OF MEDICAL SCIENCES
Verified
Journal Article
Open access
PDF file
IYİrEm Sozen Yani̇k
İrEm Sozen Yani̇k
UAUfuk Adali̇
Ufuk Adali̇
JYJamila Yassine
Jamila Yassine
FSFranziska Schmidt
Franziska Schmidt
WHWolfgang Hannak
Wolfgang Hannak
BEBahadir Ersu
Bahadir Ersu
Background/aim: This in vitro study aimed to evaluate and compare the retentive forces of novel nonmagnetic abutment designs developed as an alternative to conventional magnetic abutments for facial prostheses.Materials and methods: A plexiglass model was constructed and two extraoral implants were placed in these blocks in a parallel position. Nonmagnetic abutments made of titanium were fabricated and screwed onto the implants. The nonmagnetic systems represent a novel design and include two different abutment designs (Type 1 and Type 2) with silicone attachments. Retentive force values for three abutment types: Conventional Magnetic System (CMS), Nonmagnetic abutment Type 1 System (NMS1), and Nonmagnetic abutment Type 2 System (NMS2) were measured at 0th, 120th, 360th, 720th, and 1440th dislodging cycles using a test machine. Given the data's distribution characteristics, non-parametric tests were used for analysis. The Kruskal-Wallis test evaluated significant differences among groups, followed by Dunn's post-hoc test for specific group comparisons. The Friedman test compared the number of dislodging cycles for each group, and the Benjamini-Hochberg adjusted Wilcoxon sign-rank test was used for pairwise comparisons.Results: Both NMS1 and NMS2 groups exhibited significantly higher retentive forces compared to CMS for each of the same dislodging cycles (p<0.01). The NMS1 group showed the highest initial retentive force (9.98±0.89 N), followed by the NMS2 group (9.65±0.35 N), but this difference was not statistically significant. Significant differences in retention force values were observed among the three groups across the dislodging cycles (p<0.001). The lowest retentive force in the last dislodging cycle was observed in the CMS group (3.39±0.04 N). Additionally, the retention forces decreased in all groups with each increasing dislodging cycle.Conclusion: The two newly developed nonmagnetic systems displayed higher retentive forces compared to the magnetic systems and can be considered a viable alternative abutment option for facial prostheses.

11 February 2026 in Journal of Dentistry
Verified
Journal Article
Open access
GÇGülce Çakmak
Gülce Çakmak
MDMustafa Borga Donmez
Mustafa Borga Donmez
EEEce Ersöz
Ece Ersöz
ATAlmira Ada Diken Türksayar
Almira Ada Diken Türksayar
HAHakan Arınç
Hakan Arınç
SPStefano Pieralli
Stefano Pieralli
To evaluate the surface and positional trueness of removable dies fabricated using fused filament fabrication (FFF), compared to dies produced with digital light processing (DLP), addressing the limited evidence on the deviations of FFF-based removable dies. A typodont with a prepared right mandibular first molar was digitized to design a removable die and corresponding hollow partial arch cast. Forty dies (n = 10) and four casts (n = 1) were fabricated using FFF (Filadent Aligner [FF-AL], Filadent Gypsum [FF-GP], Filadent Tray [FF-TR]) or DLP (DentaModel [DM]). Dies and their positions in the casts were digitized to assess surface (crown, root, root base, overall) and positional (crown region and point-based) deviations. Data were analyzed either with one-way analysis of variance (surface deviations) or Kruskal-Wallis tests (positional deviations, α = 0.05). DM exhibited the lowest crown region and overall deviations, followed by FF-TR (P < 0.001). Root deviations increased in the order of DM, FF-TR, FF-AL, and FF-GP, whereas FF-TR had the lowest base of the root deviations (P < 0.001). Seated FF-GP dies had lower crown region deviations than the other FFF-based dies, while DM led to lower deviations than FF-TR (P ≤ 0.041). FF-AL showed lower point-based deviations than FF-GP (P = 0.001). FFF-fabricated dies showed lower surface trueness than DM dies, with FF-TR achieving the highest trueness among FFF dies. Positional deviations remained within clinically acceptable limits, though FF-TR dies tended to be positioned coronally and the others apically. FFF may be used to produce clinically acceptable dies, but DLP offers superior surface trueness. Removable dies produced with the tested polylactic acid filaments and FFF printer may serve as alternatives to those fabricated with the tested resin and vat polymerization printer, given the small and potentially clinically irrelevant differences in surface deviations and clinically acceptable mean positional deviations.