Irem Sozen Yanik

Irem Sozen Yanik

Auto-generated profile, based on publicly available information

Irem Sozen Yanik

Department of Prosthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
DHDilara Sahin Hazir
Dilara Sahin Hazir
IYIrem Sozen Yanik
Irem Sozen Yanik
BGBarış Güncü
Barış Güncü
RCR. Senay Canay
R. Senay Canay
The mechanical properties of framework materials significantly influence stress distribution and the long-term success of implant-supported prostheses. Although titanium, cobalt-chromium, zirconia, and polyether ether ketone (PEEK) are widely used, their biomechanical performance under dynamic loading conditions remains insufficiently investigated. This study aimed to evaluate the biomechanical behavior of four framework materials with different Young's modulus using dynamic finite element stress analysis. A 3D edentulous maxillary model was extracted from a computer tomography (CT) database. Bone level implants with conical connection designs were placed in the anterior (canine) and posterior (first molar) areas. Anterior implants were parallel, yet posterior implants were inclined distally by 30 degrees. According to the framework material, four groups were formed: cobalt-chromium (Co-Cr), zirconia (Zr), titanium (Ti), and polyether ether ketone (PEEK). For each framework material, twelve separate models of analysis were created by applying force in three different orientations. Dynamic forces were employed to replicate the chewing process. Principal and von Mises stresses were measured and evaluated. The PEEK framework exhibited the highest maximum von Mises stress values (372.55 MPa) on the abutment and the highest maximum principle stress values (59.27 MPa) in the cortical bone. The Co-Cr framework had the lowest minimum principle stress (3.98 MPa) in the trabecular bone. The displacements of the Co-Cr, Zr, Ti, and PEEK frameworks were 0.15 mm, 0.15 mm, 0.17 mm, and 0.35 mm, respectively. Frameworks having a greater Young's modulus are less susceptible to deformation.

17 October 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
IYIrem Sozen Yanik
Irem Sozen Yanik
DHDilara Sahin Hazir
Dilara Sahin Hazir
DADamla Bilgin Avsar
Damla Bilgin Avsar
The present study aimed to evaluate the performance of four large language models (LLMs)—ChatGPT-4o (OpenAI, San Francisco, CA, USA), Gemini 2.5 Flash (Google AI, Mountain View, CA, USA), Claude Sonnet 4 (Anthropic, San Francisco, CA, USA), and DeepSeek V3 (DeepSeek AI, Hangzhou, China)—in answering multiple-choice questions related to maxillofacial prosthetics in both Turkish and English. A total of 45 five-option multiple-choice questions were developed based on Clinical Maxillofacial Prosthetics by Thomas D. Taylor. Each question was submitted to the LLMs in two languages (Turkish and English). Responses were scored by three prosthodontists using a 3-point scale to evaluate both correctness and explanatory quality of the answers. Statistical analyses were performed to evaluate performance differences and cross-lingual consistency. A p-value < 0.05 was considered statistically significant. No statistically significant differences were observed among the four LLMs in either language (p = 0.128 for English; p = 0.729 for Turkish). Gemini achieved the highest score in English, with 81.1% accuracy, while Claude and DeepSeek both scored 78.9% in Turkish. Strong and statistically significant positive correlations were observed between English and Turkish scores across all LLMs, indicating consistent relative performance regardless of language. When answering maxillofacial prosthetics questions, LLMs demonstrated comparable performance in both Turkish and English. Their consistent ranking suggests potential reliability in cross-lingual knowledge generation and highlights their value as effective tools in multilingual dental education and clinical decision support.

31 May 2024 in Journal of Prosthodontics
Verified
Journal Article
Open access
IYIrem Sozen Yanik
Irem Sozen Yanik
BKBetül Kesim
Betül Kesim
BEBahadır Ersu
Bahadır Ersu
UKUzay Koc-Vural
Uzay Koc-Vural
Purpose: To compare the impact of four effervescent vitamin tablets on the surface roughness, microhardness, and color of human enamel and contemporary composite resins.Material and Methods: Sixty enamel and a total of 240 anterior (Gradia Direct Anterior), posterior (Gradia Direct Posterior), and universal composite resin (Filtek Ultimate) specimens (n = 60 per group) were fabricated. Each group was subdivided into five subgroups (n = 12, per subgroup). The specimens were subsequently immersed in YOUPLUS, Redoxon, Sunlife Immuvit, and Sambucol effervescent vitamin solutions for 2 min per day over 30 days. Distilled water was used as control. Subsequently, surface roughness (Ra) was detected using a profilometer, and microhardness (VHN) was measured using a microhardness tester. A spectrophotometer device was used to record the L,a,b color coordinates of the specimens after 24 h, 7 days, and 30 days, and the color changes (ΔE00) of the groups were calculated. The data were analyzed by ANOVA, two‐way ANOVA, Kruskal‐Wallis, Levene's, and Fisher's least significant difference (LSD) tests (p < 0.05). SEM analysis was conducted on one randomly selected specimen per group (×1000).Results: In terms of surface roughness, material X vitamin interactions were found significant (p < 0.05). The increase in Ra from 24 h to 30 days was found significant (p < 0.05) except for Gradia Direct Anterior X Redoxon, Sunlife Immuvit and Sambucol, Filtek Ultimate X Sunlife Immuvit and Sambucol, and all control groups. Ra changes were also concluded by SEM. Regarding VHNs, material X vitamin interactions were significant (p < 0.005), except for all Filtek Ultimate subgroups. The changes in VHNs of the groups from 24 h to 30 days were significant for all enamel and Gradia Direct Anterior X YOUPLUS, Gradia Posterior X YOUPLUS, Sunlife Immuvit, and Sambucol groups (p < 0.05). In terms of ΔE00, significant differences were observed between the 7 days and 30 days in the enamel (p = 0.047), Gradia Direct Anterior (p = 0.019), and Gradia Direct Posterior groups (p = 0.038).Conclusions: Daily consumption of effervescent vitamin tablets can increase surface roughness, decrease microhardness, and influence the color of human enamel and contemporary anterior, posterior, and universal composite resins after a 30‐day period.

23 March 2026 in Clinical Oral Investigations
Verified
Journal Article
Open access
PDF file
IYIrem Sozen Yanik
Irem Sozen Yanik
DHDilara Sahin Hazir
Dilara Sahin Hazir
GAGuliz Aktas
Guliz Aktas
MGM. Baris Guncu
M. Baris Guncu
Objectives: This laboratory study aimed to investigate the effects of toothbrushing with different toothpaste formulations on the color stability and surface roughness of CAD/CAM restorative materials following coffee-staining thermocycling. Materials and methods: A total of 160 specimens were prepared from four restorative materials: IPS e.max CAD, CEREC Tessera, Shofu Block HC, and VITA Enamic ( n = 40 each). Following initial measurements, specimens underwent thermocycling in a coffee solution (5000 cycles) to simulate staining. Each group was subsequently divided and brushed with either a whitening toothpaste containing hydrated silica and hydrogen peroxide or a non-whitening toothpaste containing hydrated silica only. A total of 10,000 brushing cycles were performed under standardized conditions. Color stability was assessed using ΔE₀₀ values, and surface roughness was quantified using the Ra parameter at baseline, after thermocycling, and after brushing. Data were analyzed using Kruskal–Wallis and Mann–Whitney U tests with the significance threshold set at p < 0.05. SEM analysis was conducted on one randomly selected specimen per group (x1000). Results: Statistically significant differences in color stability, as assessed by ΔE₀₀ values, were observed among the tested materials ( p < 0.001). Resin-based groups, particularly Shofu Block HC, exhibited the greatest reduction in color stability after coffee thermocycling and subsequent brushing (ΔE₀₀ = 1.069, p < 0.001), whereas glass-ceramics (IPS e.max CAD and CEREC Tessera) demonstrated superior color stability (ΔE₀₀ ≤ 0.520). Surface roughness increased significantly in resin-containing materials (VITA Enamic ΔRa = 0.036; Shofu Block HC ΔRa = 0.020) compared with glass-ceramics ( p < 0.001). No significant differences were detected between whitening and non-whitening toothpastes for either parameter across all groups ( p > 0.05). Ra changes were also concluded by SEM. Conclusion: The performance of restorative materials under staining and mechanical aging stressors is material-dependent. Glass-ceramics displayed superior color stability after coffee exposure and greater resistance to brushing-related surface degradation, whereas resin-containing materials were more vulnerable. The choice of toothpaste formulation did not significantly affect color stability or surface characteristics, suggesting that intrinsic material properties play a more critical role in long-term esthetic outcomes. Clinical relevance: Selection of restorative materials plays a decisive role in ensuring the long-term esthetic success of dental restorations. Since intrinsic material properties strongly influence color stability and resistance to surface degradation, clinicians should carefully consider material choice during treatment planning to achieve durable and predictable outcomes.

11 April 2026 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
STSaliha Senol Tekdemir
Saliha Senol Tekdemir
BGBarış Güncü
Barış Güncü
IYIrem Sozen Yanik
Irem Sozen Yanik
GAGuliz Aktas
Guliz Aktas
RKRasit Karakus
Rasit Karakus
NANesrin Anil
Nesrin Anil

18 February 2025 in TURKISH JOURNAL OF MEDICAL SCIENCES
Verified
Journal Article
Open access
PDF file
IYİrEm Sozen Yani̇k
İrEm Sozen Yani̇k
UAUfuk Adali̇
Ufuk Adali̇
JYJamila Yassine
Jamila Yassine
FSFranziska Schmidt
Franziska Schmidt
WHWolfgang Hannak
Wolfgang Hannak
BEBahadir Ersu
Bahadir Ersu
Background/aim: This in vitro study aimed to evaluate and compare the retentive forces of novel nonmagnetic abutment designs developed as an alternative to conventional magnetic abutments for facial prostheses.Materials and methods: A plexiglass model was constructed and two extraoral implants were placed in these blocks in a parallel position. Nonmagnetic abutments made of titanium were fabricated and screwed onto the implants. The nonmagnetic systems represent a novel design and include two different abutment designs (Type 1 and Type 2) with silicone attachments. Retentive force values for three abutment types: Conventional Magnetic System (CMS), Nonmagnetic abutment Type 1 System (NMS1), and Nonmagnetic abutment Type 2 System (NMS2) were measured at 0th, 120th, 360th, 720th, and 1440th dislodging cycles using a test machine. Given the data's distribution characteristics, non-parametric tests were used for analysis. The Kruskal-Wallis test evaluated significant differences among groups, followed by Dunn's post-hoc test for specific group comparisons. The Friedman test compared the number of dislodging cycles for each group, and the Benjamini-Hochberg adjusted Wilcoxon sign-rank test was used for pairwise comparisons.Results: Both NMS1 and NMS2 groups exhibited significantly higher retentive forces compared to CMS for each of the same dislodging cycles (p<0.01). The NMS1 group showed the highest initial retentive force (9.98±0.89 N), followed by the NMS2 group (9.65±0.35 N), but this difference was not statistically significant. Significant differences in retention force values were observed among the three groups across the dislodging cycles (p<0.001). The lowest retentive force in the last dislodging cycle was observed in the CMS group (3.39±0.04 N). Additionally, the retention forces decreased in all groups with each increasing dislodging cycle.Conclusion: The two newly developed nonmagnetic systems displayed higher retentive forces compared to the magnetic systems and can be considered a viable alternative abutment option for facial prostheses.