5 July 2023 in Biomechanics and Modeling in Mechanobiology
Adverse ventricular remodeling following acute myocardial infarction (MI) may induce ventricular dilation, fibrosis, and loss of global contractile function, possibly resulting in heart failure (HF). Understanding the relation between the time-dependent changes in material properties of the myocardium and the contractile function of the heart may further our understanding of the development of HF post-MI and guide the development of novel therapies. A finite element model of cardiac mechanics was used to model MI in a thick-walled truncated ellipsoidal geometry. Infarct core and border zone comprised 9.6 and 8.1% of the LV wall volume, respectively. Acute MI was modeled by inhibiting active stress generation. Chronic MI was modeled by the additional effect of infarct material stiffening, wall thinning and fiber reorientation. In acute MI, stroke work decreased by 25%. In the infarct core, fiber stress was reduced but fiber strain was increased, depending on the degree of infarct stiffening. Fiber work density was equal to zero. Healthy tissue adjacent to the infarct showed decreased work density depending on the degree of infarct stiffness and the orientation of the myofibers with respect to the infarct region. Thinning of the wall partially restored this loss in work density while the effects of fiber reorientation were minimal. We found that the relative loss in pump function in the infarcted heart exceeds the relative loss in healthy myocardial tissue due to impaired mechanical function in healthy tissue adjacent to the infarct. Infarct stiffening, wall thinning and fiber reorientation did not affect pump function but did affect the distribution of work density in tissue adjacent to the infarct.
31 August 2023 in Computational Mechanics
The finite element method (FEM) is commonly used in computational cardiac simulations. For this method, a mesh is constructed to represent the geometry and, subsequently, to approximate the solution. To accurately capture curved geometrical features many elements may be required, possibly leading to unnecessarily large computation costs. Without loss of accuracy, a reduction in computation cost can be achieved by integrating geometry representation and solution approximation into a single framework using the isogeometric analysis (IGA) paradigm. In this study, we propose an IGA framework suitable for echocardiogram data of cardiac mechanics, where we show the advantageous properties of smooth splines through the development of a multi-patch anatomical model. A nonlinear cardiac model is discretized following the IGA paradigm, meaning that the spline geometry parametrization is directly used for the discretization of the physical fields. The IGA model is benchmarked with a state-of-the-art biomechanics model based on traditional FEM. For this benchmark, the hemodynamic response predicted by the high-fidelity FEM model is accurately captured by an IGA model with only 320 elements and 4700 degrees of freedom. The study is concluded by a brief anatomy-variation analysis, which illustrates the geometric flexibility of the framework. The IGA framework can be used as a first step toward an efficient workflow for an improved understanding of, and clinical decision support for, the treatment of cardiac diseases like heart rhythm disorders.
1 August 2024 in Biomechanics and Modeling in Mechanobiology
Acute myocardial infarction (MI) leads to a loss of cardiac function which, following adverse ventricular remodeling (AVR), can ultimately result in heart failure. Tissue-engineered contractile patches placed over the infarct offer potential for restoring cardiac function and reducing AVR. In this computational study, we investigate how improvement of pump function depends on the orientation of the cardiac patch and the fibers therein relative to the left ventricle (LV). Additionally, we examine how model outcome depends on the choice of material properties for healthy and infarct tissue. In a finite element model of LV mechanics, an infarction was induced by eliminating active stress generation and increasing passive tissue stiffness in a region comprising 15% of the LV wall volume. The cardiac patch was modeled as a rectangular piece of healthy myocardium with a volume of 25% of the infarcted tissue. The orientation of the patch was varied from 0 to $$150^ \circ $$ relative to the circumferential plane. The infarct reduced stroke work by 34% compared to the healthy heart. Optimal patch support was achieved when the patch was oriented parallel to the subepicardial fiber direction, restoring 9% of lost functionality. Typically, about one-third of the total recovery was attributed to the patch, while the remainder resulted from restored functionality in native myocardium adjacent to the infarct. The patch contributes to cardiac function through two mechanisms. A contribution of tissue in the patch and an increased contribution of native tissue, due to favorable changes in mechanical boundary conditions.
11 June 2025 in Journal of Biomechanical Engineering
Tissue-engineered contractile patches offer a promising therapeutic strategy to restore cardiac function following myocardial infarction (MI) and mitigate adverse ventricular remodeling, a key contributor to the progression of heart failure (HF). However, experimental and numerical studies indicate that their functionality may be affected by the mechanical properties of the underlying infarct. In this computational study, we investigate how infarct tissue stiffness and wall thickness influence the ability of a contractile cardiac patch to restore cardiac function. A model of cardiac mechanics was used to model MI in a region comprising 15% of the left ventricle. In this region, active stress generation was eliminated, and passive tissue stiffness and wall thickness were varied. The cardiac patch was modeled as a rectangular piece of healthy myocardium with a volume of 25% of the infarcted tissue. Following MI, stroke work decreased by 32% compared to the healthy heart. This loss increased with increasing infarct tissue stiffness and decreasing infarct wall thickness. In the most favorable case, the cardiac patch restored up to 15% of this loss, of which about one-third was attributed to a direct contribution of the patch and two-thirds to improved function in adjacent healthy myocardium. Decreasing tissue stiffness improved restoration of cardiac pump function and the relative contribution of the patch. Conversely, while reduced wall thickness improved restoration of pump function, it decreased the relative contribution of the patch. Lower infarct stiffness, either through tissue stiffness or wall thinning, allows more cardiac function to be restored via patch implantation.
19 June 2024 in Heritage Science
The recent multi-analytical study carried out on the Van Eyck’s Ghent Altarpiece showed the simultaneous presence of several kinds of metal carboxylates in oil-rich glaze layers. This outcome raised the question whether these carboxylates had already formed during the preparation of the oil binder by the artists. In the case of early-stage formation, they may have had an impact on the drying rate of the resulting oil, as well as on its handling properties. This hypothesis was investigated using a model system of in-house-prepared linseed oil containing incremental concentrations (2–5–10 wt.%) of relevant metal carboxylates (i.e. Ca-, Zn-, Cu-, and Pb oleates and stearates). This paper describes the influence of these type of molecules on the drying rate of linseed oil and, to an extent, on its viscosity. The drying time of the linseed oil, to which one or more metal carboxylates were added, was measured with a drying recorder while the viscosity was assessed with a rheometer. When introduced together, some of these metal carboxylates act in synergy to shorten the drying time with respect to the situation when the same metal carboxylates were added separately to linseed oil. Mixtures of Ca- and Zn-oleates proved to have a larger effect than other binary combinations. Addition of two metal oleates (combination of Ca/Zn/Cu/Pb) reduced the drying time even more. On the other hand, specific combinations of three metal stearates and/or oleates also demonstrated a significant synergistic effect towards increasing the viscosity of the binder. Especially combinations of Ca/Zn/Cu and Ca/Zn/Pb stearates and oleates gave rise to the highest level of linseed oil viscosity increase, when compared to the situation in which the same metal carboxylates were added separately.