Robin Willems

Mr. Robin Willems

Eindhoven University of Technology
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2023 in Computational Mechanics
Verified
Journal Article
Open access
PDF file
RWRobin Willems
Robin Willems
KJKoen L. P. M. Janssens
Koen L. P. M. Janssens
PBPeter H. M. Bovendeerd
Peter H. M. Bovendeerd
CVClemens Verhoosel
Clemens Verhoosel
OSOlaf Van der Sluis
Olaf Van der Sluis
The finite element method (FEM) is commonly used in computational cardiac simulations. For this method, a mesh is constructed to represent the geometry and, subsequently, to approximate the solution. To accurately capture curved geometrical features many elements may be required, possibly leading to unnecessarily large computation costs. Without loss of accuracy, a reduction in computation cost can be achieved by integrating geometry representation and solution approximation into a single framework using the isogeometric analysis (IGA) paradigm. In this study, we propose an IGA framework suitable for echocardiogram data of cardiac mechanics, where we show the advantageous properties of smooth splines through the development of a multi-patch anatomical model. A nonlinear cardiac model is discretized following the IGA paradigm, meaning that the spline geometry parametrization is directly used for the discretization of the physical fields. The IGA model is benchmarked with a state-of-the-art biomechanics model based on traditional FEM. For this benchmark, the hemodynamic response predicted by the high-fidelity FEM model is accurately captured by an IGA model with only 320 elements and 4700 degrees of freedom. The study is concluded by a brief anatomy-variation analysis, which illustrates the geometric flexibility of the framework. The IGA framework can be used as a first step toward an efficient workflow for an improved understanding of, and clinical decision support for, the treatment of cardiac diseases like heart rhythm disorders.

1 April 2024 in Computer Methods in Applied Mechanics and Engineering
Verified
Journal Article
Open access
RWRobin Willems
Robin Willems
LVLex Verberne
Lex Verberne
OSOlaf Van der Sluis
Olaf Van der Sluis
CVClemens Verhoosel
Clemens Verhoosel

16 June 2023
Verified
Book Chapter
Closed access
PDF file
RWRobin Willems
Robin Willems
EKE. Kruithof
E. Kruithof
KJK. L. P. M. Janssens
K. L. P. M. Janssens
MCM. J. M. Cluitmans
M. J. M. Cluitmans
OSO. van der Sluis
O. van der Sluis
CVC. V. Verhoosel
C. V. Verhoosel

Verified
Journal Article
Open access
PDF file
RWRobin Willems
Robin Willems
Léo FriedrichLéo Friedrich
Léo Friedrich
CVClemens Verhoosel
Clemens Verhoosel
Axial-Flux Permanent Magnet (AFPM) machines have gained popularity over the past few years due to their compact design. Their application can be found, for example, in the automotive and medical sectors. For typically considered materials, excessive heat can be generated, causing possible irreversible damage to the magnets, bonding, or other structural parts. In order to optimize cooling, knowledge of the flow and the consequent temperature distribution is required. This paper discusses the flow types and heat transfer present inside a typical AFPM machine. An Isogeometric Analysis (IGA) laminar-energy model is developed using the Nutils open-source Python package. The developed analysis tool is used to study the effects of various important design parameters, such as the air-inlet, the gap-length, and the rotation speed on the heat transfer in an AFPM machine. It is observed that the convective heat transfer at the stator core is negatively affected by adding an air-inlet. However, the heat dissipation of the entire stator improves as convective heat transfer occurs within the air-inlet.

13 November 2024 in arXiv
Verified
Preprint
Open access
PDF file
RWRobin Willems
Robin Willems
PFPeter Förster
Peter Förster
SSSebastian Schöps
Sebastian Schöps
OSOlaf van der Sluis
Olaf van der Sluis
CVClemens V. Verhoosel
Clemens V. Verhoosel
Cardio-mechanical models can be used to support clinical decision-making. Unfortunately, the substantial computational effort involved in many cardiac models hinders their application in the clinic, despite the fact that they may provide valuable information. In this work, we present a probabilistic reduced-order modeling (ROM) framework to dramatically reduce the computational effort of such models while providing a credibility interval. In the online stage, a fast-to-evaluate generalized one-fiber model is considered. This generalized one-fiber model incorporates correction factors to emulate patient-specific attributes, such as local geometry variations. In the offline stage, Bayesian inference is used to calibrate these correction factors on training data generated using a full-order isogeometric cardiac model (FOM). A Gaussian process is used in the online stage to predict the correction factors for geometries that are not in the training data. The proposed framework is demonstrated using two examples. The first example considers idealized left-ventricle geometries, for which the behavior of the ROM framework can be studied in detail. In the second example, the ROM framework is applied to scan-based geometries, based on which the application of the ROM framework in the clinical setting is discussed. The results for the two examples convey that the ROM framework can provide accurate online predictions, provided that adequate FOM training data is available. The uncertainty bands provided by the ROM framework give insight into the trustworthiness of its results. Large uncertainty bands can be considered as an indicator for the further population of the training data set.

3 May 2023 in arXiv
Verified
Preprint
Open access
PDF file
RWRobin Willems
Robin Willems
KJKoen L. P. M. Janssens
Koen L. P. M. Janssens
PBPeter H. M. Bovendeerd
Peter H. M. Bovendeerd
CVClemens V. Verhoosel
Clemens V. Verhoosel
OSOlaf van der Sluis
Olaf van der Sluis
The finite element method (FEM) is commonly used in computational cardiac simulations. For this method, a mesh is constructed to represent the geometry and, subsequently, to approximate the solution. To accurately capture curved geometrical features many elements may be required, possibly leading to unnecessarily large computation costs. Without loss of accuracy, a reduction in computation cost can be achieved by integrating geometry representation and solution approximation into a single framework using the Isogeometric Analysis (IGA) paradigm. In this study, we propose an IGA framework suitable for echocardiogram data of cardiac mechanics, where we show the advantageous properties of smooth splines through the development of a multi-patch anatomical model. A nonlinear cardiac model is discretized following the IGA paradigm, meaning that the spline geometry parametrization is directly used for the discretization of the physical fields. The IGA model is benchmarked with a state-of-the-art biomechanics model based on traditional FEM. For this benchmark, the hemodynamic response predicted by the high-fidelity FEM model is accurately captured by an IGA model with only 320 elements and 4,700 degrees of freedom. The study is concluded by a brief anatomy-variation analysis, which illustrates the geometric flexibility of the framework. The IGA framework can be used as a first step toward an efficient workflow for an improved understanding of, and clinical decision support for, the treatment of cardiac diseases like heart rhythm disorders.