Yunzhu Chen

Yunzhu Chen

Auto-generated profile, based on publicly available information

Yunzhu Chen

College of Electrical Engineering, Sichuan University, Chengdu, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YWYing Wang
Ying Wang
HHHai-Shan He
Hai-Shan He
XXXian-Yong Xiao
Xian-Yong Xiao
SLShun-Yi Li
Shun-Yi Li
YCYun-Zhu Chen
Yun-Zhu Chen
HMHai-Xing Ma
Hai-Xing Ma
Knowledge of the disturbance of the concerned bus is essential to make decisions to mitigate voltage sags. The most commonly used method is to estimate the state of voltage sag in the absence of a monitor. However, the traditional state estimation method, which is designed for rectangular voltage sags, is difficult to apply to multi-stage voltage sags (MSVSs). This study proposes an MSVS state-estimation method based on event-deduction models. First, we propose a method to identify the causes of MSVSs. Second, we present a method to calculate the matrix of relay protection trips (MRPT), which corresponds to the fault clearing time of the relay protection and a method to calculate the fault power line set to reduce the computing workload of the MRPT-based estimation method. Third, we propose a method to calculate the impedance matrix of a power system under different disturbance events, resulting in different stages of the MSVS and an event-deduction model based on this impedance matrix to deduce these events. Furthermore, we present a model to estimate the state of voltage sag for MSVS based on the event deduction result. Finally, we use the IEEE-118 system to validate the proposed method.

2 November 2020 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
YCYun‐Zhu Chen
Yun‐Zhu Chen
XXXian‐Yong Xiao
Xian‐Yong Xiao
YWYing Wang
Ying Wang
HZHua‐Ying Zhang
Hua‐Ying Zhang
HLHong‐Xin Li
Hong‐Xin Li
QWQing Wang
Qing Wang
Economic losses caused by power disturbances such as voltage sags and short interruptions have become an important concern for high‐tech enterprises in recent years. A potential solution to address this challenge is to provide value‐added services such as voltage sag insurance to help enterprises to manage voltage sag risks. This study presents a severity index‐based voltage sag insurance scheme including the liability, period, premium and compensation. Voltage sag severity is used as the index of insurance to define the trigger and limit of liability. The production value of enterprises suffered with voltage sags is obtained by introducing economics thus can accurately quantify the interaction between technical indexes of voltage sag and the economic indexes required for premium. Finally, case studies of three high‐tech enterprises located in China have proved the correctness and rationality of the proposed insurance scheme.

30 July 2018 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
XXXian‐Yong Xiao
Xian‐Yong Xiao
YCYun‐Zhu Chen
Yun‐Zhu Chen
YWYing Wang
Ying Wang
YMYuan‐Qian Ma
Yuan‐Qian Ma
Nowadays, more and more high‐tech enterprises pay great attention to the enormous losses and risks caused by voltage sag. There is an urgent desire for voltage sag insurance. However, a feasible insurance mechanism is not yet available. Relationships among stakeholders (customers, insurance institution, power utility and government) are studied based on the analysis of insurability of voltage sag loss risk, and three possible voltage sag insurance mechanisms are proposed. Multi‐objective two‐stage decision‐making method is introduced to combine the expectations of attributes of mechanisms for different stakeholders; the proposed method can simplify the fuzziness and the complexity of evaluating the process. This method combines the integrating scattered information into effective evaluation information, and it can reflect the recognition of different mechanisms by all the stakeholders objectively. This method can determine voltage sag insurance mechanisms, which are with the high feasibility to satisfy the requirement of all the stakeholders and to make sure all attributes are in good condition. Finally, the results of case studies for three high‐tech customers located in the high‐tech park have proved the correctness and rationality of the recommended insurance mechanism.

15 November 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YCYun-Zhu Chen
Yun-Zhu Chen
YWYing Wang
Ying Wang
XXXian-Yong Xiao
Xian-Yong Xiao
ZZZixuan Zheng
Zixuan Zheng
HZHua-Ying Zhang
Hua-Ying Zhang
XWXian Wu
Xian Wu
Voltage sag insurance (VSI) is an effective measure to reduce the voltage sag loss and risk for enterprises with insufficient mitigation confidence or economic ability. However, due to the lack of understanding of voltage sag risk (VSR), it is difficult for power utilities to identify the enterprises with VSI demands, and it is also unable to realize differentiated premium according to different enterprises' situations. To solve the above problems, this paper proposes an improved voltage sag premium model based on VSR. Firstly, the VSR factors are analyzed, such as the hazard, the vulnerability, the exposure. The process immune time is introduced to describe the vulnerability. Based on the traditional consideration of only the ability of users to resist voltage sag, the ability of users to recover from voltage sag is further considered. Then, the risk evaluation model of voltage sag is established. The evaluation results can help power utilities to judge whether enterprises have the demand of VSI. Finally, the improved premium model of VSI based on VSR is constructed to ensure the differentiation and rationalization of the premium. The correctness and rationality of this method are proved by ten manufacturing enterprises in China by analyzing the VSR and comparing the premium before and after the improvement.

8 May 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YWYing Wang
Ying Wang
DTDajie Tu
Dajie Tu
QWQing Wang
Qing Wang
HZHuaying Zhang
Huaying Zhang
YCYunzhu Chen
Yunzhu Chen
A perturbation injection device has become a key tool for obtaining impedance information by administering a perturbation signal to the system under investigation. It is important to reasonably design the injected perturbation signals in order to obtain impedance curves quickly and accurately. This article proposes a multistage design strategy for a broadband perturbation signal (BPS) intended for impedance measurement. First, initial BPS is designed considering various factors affecting the measurement accuracy, including peak, selectable frequencies, and frequency coupling. Then, an error estimation technique is introduced to assess measurement precision, with the ensuing findings applied to the subsequent BPS design stage. The iterative application of these stages allows for the continuous approximation of the real impedance curve. The article concludes with a series of simulations demonstrating both the practicality and precision of the proposed technique.

26 December 2024 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
ZZZixuan Zheng
Zixuan Zheng
SLShijie Li
Shijie Li
CHChunjun Huang
Chunjun Huang
YCYunzhu Chen
Yunzhu Chen
JMJunhao Ma
Junhao Ma
QFQiang Fu
Qiang Fu
Energy routers present a viable option for harvesting renewable energy sources (RESs) and ensure dependable electricity provision in industrial microgrids. This paper presents a multi-functional, grid-forming energy router (GFMER), accompanied by a hierarchical proactive control approach. The lower-layer controller handles the coordination strategies among photovoltaic (PV) systems, battery energy storage units (BESU), and DC/AC converters. In this layer, an optimized multi-objective droop control mechanism is presented to proactively regulate AC grid-side voltage imbalances and deviations. Meanwhile, the upper-layer control is deployed to maintain the DC bus voltage, and a novel power allocation module has been designed to enhance the dynamic transient support for grids. The effectiveness and practical value of this proposed methodology have been validated through MATLAB/Simulink and hardware-in-the-loop (HIL) experiments.