Shijie Li

Shijie Li

Auto-generated profile, based on publicly available information

Shijie Li

College of Electrical Engineering, Sichuan University, Chengdu, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2024 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
ZZZixuan Zheng
Zixuan Zheng
SLShijie Li
Shijie Li
CHChunjun Huang
Chunjun Huang
YCYunzhu Chen
Yunzhu Chen
JMJunhao Ma
Junhao Ma
QFQiang Fu
Qiang Fu
Energy routers present a viable option for harvesting renewable energy sources (RESs) and ensure dependable electricity provision in industrial microgrids. This paper presents a multi-functional, grid-forming energy router (GFMER), accompanied by a hierarchical proactive control approach. The lower-layer controller handles the coordination strategies among photovoltaic (PV) systems, battery energy storage units (BESU), and DC/AC converters. In this layer, an optimized multi-objective droop control mechanism is presented to proactively regulate AC grid-side voltage imbalances and deviations. Meanwhile, the upper-layer control is deployed to maintain the DC bus voltage, and a novel power allocation module has been designed to enhance the dynamic transient support for grids. The effectiveness and practical value of this proposed methodology have been validated through MATLAB/Simulink and hardware-in-the-loop (HIL) experiments.

28 June 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
ZZZixuan Zheng
Zixuan Zheng
SLShijie Li
Shijie Li
XCXulin Chen
Xulin Chen
CLChangsong Li
Changsong Li
In order to meet the composite demand of premium power supply and energy consumption reduction of data centers, this paper presents a reliable 2N power supply architecture for data centers including superconducting magnetic energy storage systems (SMES). The architecture features two distinct DC voltage levels: 575 V and 240 V. The 575 V DC bus integrates distributed generation (DG) and uninterruptible power supplies (UPS) to enhance energy efficiency, while the 240 V DC bus interfaces directly with the data center. Additionally, an energy management strategy is devised for this power supply configuration, and a control approach for SMES based on event-triggered mechanisms is proposed to guarantee uninterrupted power supply to the data center. A 2N architecture power system is modelled using MATLAB/Simulink, and the results validate the effectiveness and reliability of the proposed approach.

22 September 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
MZMingshun Zhang
Mingshun Zhang
XXXianyong Xiao
Xianyong Xiao
ZZZixuan Zheng
Zixuan Zheng
YCYunzhu Chen
Yunzhu Chen
SLShijie Li
Shijie Li
Xiaoyuan ChenXiaoyuan Chen
Xiaoyuan Chen
DC microgrid is regarded as a promising architecture for integrating renewable energy generators, energy storage devices, and sensitive loads with multiple voltage/current levels in oil/gas field systems. However, with the increasing penetration of renewables and power electronics, voltage sag/swell power quality issues and rapid, high-magnitude over-currents challenges under various transient and fault conditions need urgent attention. This paper presents a novel solution of multiport current-limiting interline dynamic voltage restorer (MCL-IDVR), which employs a shared one-battery energy storage unit and an N+1-port improved active full-bridge converter topology to achieve coordinated compensation among multiple circuits. The multiple output ports of this device can be simultaneously connected in series to DC lines with different voltage and current levels, enabling two coordinated functions of voltage sag/swell compensation and customizable energy-feedback fault current limiting. The working principles, control strategies, and operational modes of the MCL-IDVR are elaborated in detail. Its technical performance is validated through MW-class oilfield DC microgrid simulations and kW-class scaled-down experimental tests. Results demonstrate the device’s efficacy in mitigating voltage fluctuations and suppressing fault currents, proving the feasibility and practicality of the MCL-IDVR solution.

1 July 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
XCXulin Chen
Xulin Chen
ZZZixuan Zheng
Zixuan Zheng
SLShijie Li
Shijie Li
JRJie Ren
Jie Ren
The multiple beam pumping motors (BPMs) DC microgrid enables energy inter-feeding between motors. However, conventional voltage regulation method for this kinds of DC microgrid is achieved by voltage-threshold-based coordinated control, which suffers from response lag. To overcome the limitations of existing rule-based control methods, this paper proposed a voltage derivative-based control scheme to maintain DC bus voltage under AC faults and the load fluctuations of BPMS. Firstly, the capacity calculation method of superconducting magnetic energy storage (SMES) is given by analyzing the possible regenerative braking energy from motor loads. Then, a voltage derivative-based coordination control strategy and reference power calculation method for SMES is proposed. Compared simulation results obtained in MATLAB/Simulink leverages the fast response characteristics of SMES to mitigate voltage fluctuations.