The mechanisms leading to aneurysm occlusion after treatment with flow‐diverting devices are not fully understood. Flow modification induces thrombus formation within the aneurysm cavity, but fibrin can simultaneously accumulate and cover the device scaffold, leading to further flow modification. However, the interplay and relative importance of these processes are not clearly understood. A computational model of fibrin accumulation and flow modification after flow diversion treatment of cerebral aneurysms has been developed under the guidance of in vitro experiments and observations. The model is based on the loose coupling of flow and transport‐reaction equations that are solved separately by independent codes. Interaction or reactive terms account for thrombin production from prothrombin stimulated by thrombogenic metallic wires and inhibition by antithrombin as well as fibrin production from fibrinogen stimulated by thrombin and flow shear stress, and fibrin adhesion to device wires and already attached fibrin. The computational model was demonstrated and tested on idealized vessel and aneurysm geometries. The model was able to reproduce the salient features of fibrin accumulation after the deployment of flow‐diverting devices in idealized in vitro models of cerebral aneurysms. Namely, fibrin production in regions of high shear stress, initial accumulation at the inflow zone, and progressive occlusion of the device and corresponding flow attenuation. The computational model linking flow dynamics to fibrin production, transport, and adhesion can be used to investigate and better understand the effects that lead to fibrin accumulation and the resulting aneurysm inflow reduction and intra‐aneurysmal flow modulation.
Due to their effect on aneurysm hemodynamics, flow diverters (FD) have become a routine endovascular therapy for intracranial aneurysms. Since over- and undersizing affect the device’s hemodynamic abilities, selecting the correct device diameter and accurately simulating FD placement can improve patient-specific outcomes. The purpose of this study was to validate the accuracy of virtual flow diverter deployments in the novel Derivo® 2 device. We retrospectively analyzed blood flows in ten FD placements for which 3D DSA datasets were available pre- and post-intervention. All patients were treated with a second-generation FD Derivo® 2 (Acandis GmbH, Pforzheim, Germany) and post-interventional datasets were compared to virtual FD deployment at the implanted position for implanted stent length, stent diameters, and curvature analysis using ANKYRAS (Galgo Medical, Barcelona, Spain). Image-based blood flow simulations of pre- and post-interventional configurations were conducted. The mean length of implanted FD was 32.61 (±11.18 mm). Overall, ANKYRAS prediction was good with an average deviation of 8.4% (±5.8%) with a mean absolute difference in stent length of 3.13 mm. There was a difference of 0.24 mm in stent diameter amplitude toward ANKYRAS simulation. In vessels exhibiting a high degree of curvature, however, relevant differences between simulated and real-patient data were observed. The intrasaccular blood flow activity represented by the wall shear stress was qualitatively reduced in all cases. Inflow velocity decreased and the pulsatility over the cardiac cycle was weakened. Virtual stenting is an accurate tool for FD positioning, which may help facilitate flow FDs’ individualization and assess their hemodynamic impact. Challenges posed by complex vessel anatomy and high curvatures must be addressed.
26 December 2024 in International Journal for Numerical Methods in Biomedical Engineering
As the number of cerebral aneurysms treated with flow diverters continues to increase, it is important to understand what factors influence not only thrombus formation within the aneurysm cavity but also fibrin accumulation across the device and its associated disruption and blockage of the inflow stream. Both processes contribute to the eventual occlusion of the aneurysm or its continued patency and incomplete occlusion which may require future re‐treatment. To investigate fibrin accumulation on flow diverters placed across the neck of cerebral aneurysms, a previously developed computational model that couples flow and fibrin dynamics is used in combination with experimental in vitro models of cerebral aneurysms treated with flow diverters. Fibrin accumulation was previously investigated in four glass models of cerebral aneurysms with varying parent artery geometries placed in a flow loop at different flow rates. Corresponding computational models were constructed and compared with the experimental findings. The computational model based on fibrin production stimulated from flow shear stress and subsequent adhesion to device wires was able to reproduce and explain the fibrin accumulation patterns observed in the experimental aneurysms treated with flow diverters. Specifically, these models indicated that increasing vessel curvature, flow rate, and thrombin concentration induced faster fibrin accumulation and associated aneurysm inflow disruption and blockage. The models described and tested in this paper are valuable to understand the detailed mechanisms leading to aneurysm occlusion and healing or incomplete occlusions after treatment with flow diverting devices.
Minimally-invasive therapies are well-established treatment methods for saccular intracranial aneurysms (SIAs). Knowledge concerning fusiform IAs (FIAs) is low, due to their wide and alternating lumen and their infrequent occurrence. However, FIAs carry risks like ischemia and thus require further in-depth investigation. Six patient-specific IAs, comprising three position-identical FIAs and SIAs, with the FIAs showing a non-typical FIA shape, were compared, respectively. For each model, a healthy counterpart and a treated version with a flow diverting stent were created. Eighteen time-dependent simulations were performed to analyze morphological and hemodynamic parameters focusing on the treatment effect (TE). The stent expansion is higher for FIAs than SIAs. For FIAs, the reduction in vorticity is higher (35–75% case 2/3) and the reduction in the oscillatory velocity index is lower (15–68% case 2/3). Velocity is reduced equally for FIAs and SIAs with a TE of 37–60% in FIAs and of 41–72% in SIAs. Time-averaged wall shear stress (TAWSS) is less reduced within FIAs than SIAs (30–105%). Within this study, the positive TE of FDS deployed in FIAs is shown and a similarity in parameters found due to the non-typical FIA shape. Despite the higher stent expansion, velocity and vorticity are equally reduced compared to identically located SIAs.
Objectives: To systematically review the literature on all reports of magnetic resonance imaging (MRI) use in patients with external fixators and evaluate for adverse events. Data Sources: MEDLINE, Embase, and Cochrane were searched for English-language articles from January 1, 1995, to July 14, 2024. Study Selection: Studies that described MRI use in a patient with an external fixator and measured whether adverse events occurred while the patient underwent MRI were included for analysis. Data Extraction: Two reviewers independently reviewed, selected included studies, and extracted data. A third reviewer resolved any discrepancies. Data Synthesis: Six studies (Level IV evidence) were identified, including 358 MRI instances. The quality of the studies was evaluated using the Institute of Health Economics checklist for the quality appraisal of case series studies. No descriptive statistics were performed. Results: Overall, we found no reports (0.0%) of serious patient harm, including burns and changes in the stability of the external fixation. Four (1.1%) reports of patients feeling discomfort or pain led to early termination of the MRI with no long-term sequelae. Conclusions: Overall, no patient harm events were reported in our systematic review of the available literature. Further studies are recommended to help develop future guidelines on using MRI in patients with external fixation. Currently, there is no known clinical evidence to suggest that MRI is not safe in the setting of a patient with an extremity external fixator; however, this topic remains controversial. The benefits of using MRI likely outweigh potential minor risks in this patient population, and the authors recommend against blanket restrictions prohibiting the use of MRI in patients with external fixation. Level of Evidence: Therapeutic Level IV.