Andre Campos De Moura

Andre Campos De Moura

Auto-generated profile, based on publicly available information

Andre Campos De Moura

Universidade Estadual de Londrina, Brazil

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in DYNA
Verified
Journal Article
Open access
PDF file
Gersson Fernando Barreto SandovalGersson Fernando Barreto Sandoval
Gersson Fernando Barreto Sandoval
Isaac GalobardesIsaac Galobardes
Isaac Galobardes
NSNicole Schwantes-Cezario
Nicole Schwantes-Cezario
AMAndré Campos Moura
André Campos Moura
BTBerenice Martins Toralles
Berenice Martins Toralles
The aim of this study was to propose a correlation for the hydraulic parameters of pervious concrete (PC). Thus, three aggregates from civil construction waste and one basalt aggregate (reference) were used to produce PC. The ratio c/a (cement: aggregate) 1:3.26 and a w/c ratio of 0.34 were used in all mixtures. Compressive and flexure tensile strength tests were performed to mechanically characterize the mixtures produced, whereas porosity and constant head permeability tests were also carried out to assess the material hydraulic properties.Firstly, the experimental results were compared with the requirements established in international guidelines (ACI 522R-10, NBR 16416(2015) and VTT-R-080225-13). The results complied with the guidelines indicating it is feasible to produce pervious concretes with the sustainable aggregates used in the study in low structural applications such as walkways. On the other hand, a correlation between permeability and porosity was proposed based on Darcy’s and Bernoulli’s laws. The proposed equation, obtained by means of a non-linear regression, is an exponential equation that characterizes the hydraulic efficiency of the internal channels of the material considering the pores interconnection. The correlation between porosity and permeability was finally validated using results from the literature showing the same trend found in laboratory, and therefore it was demonstrated that the proposed correlation in an efficient tool to predict the hydraulic efficiency of pervious concrete.

1 May 2020 in Journal of Building Engineering
Verified
Journal Article
Closed access
Gersson Fernando Barreto SandovalGersson Fernando Barreto Sandoval
Gersson Fernando Barreto Sandoval
Isaac GalobardesIsaac Galobardes
Isaac Galobardes
ACAndré Campos
André Campos
BTBerenice.M. Toralles
Berenice.M. Toralles

9 June 2022 in Journal of Cleaner Production
Verified
Journal Article
Closed access
Gersson Fernando Barreto SandovalGersson Fernando Barreto Sandoval
Gersson Fernando Barreto Sandoval
RPRicardo Pieralisi
Ricardo Pieralisi
KRKathleen Dall Bello de Souza Risson
Kathleen Dall Bello de Souza Risson
AMAndre Campos de Moura
Andre Campos de Moura
BTBerenice M. Toralles
Berenice M. Toralles

1 December 2020 in Case Studies in Construction Materials
Verified
Journal Article
Open access
Gersson Fernando Barreto SandovalGersson Fernando Barreto Sandoval
Gersson Fernando Barreto Sandoval
Isaac GalobardesIsaac Galobardes
Isaac Galobardes
AMAndre Campos De Moura
Andre Campos De Moura
BTBerenice M. Toralles
Berenice M. Toralles

1 December 2021 in Case Studies in Construction Materials
Verified
Journal Article
Open access
KRKathleen Dall Bello de Souza Risson
Kathleen Dall Bello de Souza Risson
Gersson Fernando Barreto SandovalGersson Fernando Barreto Sandoval
Gersson Fernando Barreto Sandoval
FPFrancieli S. Cofani Pinto
Francieli S. Cofani Pinto
MCMarcos Vinício Camargo
Marcos Vinício Camargo
AMAndré Campos De Moura
André Campos De Moura
BTBerenice Martins Toralles
Berenice Martins Toralles

1 June 2019 in Revista IBRACON de Estruturas e Materiais
Verified
Journal Article
Open access
Gersson Fernando Barreto SandovalGersson Fernando Barreto Sandoval
Gersson Fernando Barreto Sandoval
Isaac GalobardesIsaac Galobardes
Isaac Galobardes
CDC. Dias
C. Dias
ACA. Campos
A. Campos
BTB. M. Toralles
B. M. Toralles
The objective of this work is to make feasible the use of FEA slag instead of the conventional bulk aggregate in the pervious concrete (PC) production, reaching the minimum parameters required by NBR16416/2015 and ACI 522R-10. This substitution would minimize the use of natural aggregates, besides taking advantage of a residue that has no specific destination. In order to reach the objective, three FEAs with different grain sizes were chosen: 6-10 mm (A), 10-20 mm (B) and finally a mixture of the two previous ones (C) in the proportion 30-70 respectively. In order to evaluate its mechanical behavior, tests of compressive strength and flexural tensile tests were carried out, while the evaluation of the hydraulic behavior, porosity and constant head permeability test were performed. The compressive strength varies from 19-31MPa and 3-4MPa for flexural tensile strength was obtained. In hydraulic terms, the porosity varied from 15-20% and the permeability coefficient was 10-12mm/s. There is also a direct influence of grains of size less than 4.8 mm (small aggregate) on the compressive strength and permeability of PCs. At the end of the results, it was possible to establish a correlation between the compressive strength, the permeability and the percentage of grains inferior to 4.8mm (sand%), being this positive in relation to the studied variables, that is, the mechanical and hydraulics. Therefore, it has been concluded that the total substitution of conventional aggregates by FEA in CoPe manufacturing will comply with the minimum parameters of NBR 16416/2015.