Daniel Rohrbach

Daniel Rohrbach

Auto-generated profile, based on publicly available information

Daniel Rohrbach

Verasonics Inc. 11335 NE 122nd Way Kirkland WA 98034 United States

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
DRDaniel Rohrbach
Daniel Rohrbach
JMJonathan Mamou
Jonathan Mamou
Quantitative acoustic microscopy (QAM) at frequencies exceeding 100 MHz has become an established imaging tool to depict acoustical and mechanical properties of soft biological tissues at microscopic resolutions. In this study we investigate a novel autoregressive (AR) model to improve signal processing and parameter estimation and to test its applicability to QAM. The performance of the AR model for estimating acoustical parameters of soft tissues (i.e., acoustic impedance, speed of sound, and attenuation) was compared to the performance of the Hozumi model using simulated ultrasonic QAM-signals and using experimentally measured signals from thin (i.e., 12 and 6 μm) sections of human lymph-node and pig-cornea tissue specimens. Results showed that the AR and Hozumi methods performed equally well (i.e., produced an estimation error of 0) in signals with low, linear attenuation in the tissue and high impedance contrast between the tissue and the coupling medium. However, the AR model outperformed the Hozumi model in estimation accuracy and stability (i.e., parameter error variation and number of outliers) in cases of (1) thin tissuesample thickness and high tissue-sample speed of sound, (2) small impedance contrast between the tissue sample and the coupling medium, (3) high attenuation in the tissue sample and (4) nonlinear attenuation in the tissue sample. Furthermore, the ARmodel allows estimating the exponent of non-linear attenuation. The results of this study suggest that the AR-model approach can improve current QAM by providing more-reliable, quantitative, tissue-property estimates, and also provides additional values of parameters related to non-linear attenuation.

3 April 2024 in Batteries & Supercaps
Verified
Journal Article
Open access
SMSimon Montoya‐Bedoya
Simon Montoya‐Bedoya
EGEsteban Garcia‐Tamayo
Esteban Garcia‐Tamayo
DRDaniel Rohrbach
Daniel Rohrbach
JGJuan Pablo Gaviria‐Cardona
Juan Pablo Gaviria‐Cardona
HMHader V. Martinez‐Tejada
Hader V. Martinez‐Tejada
MBMiguel Bernal
Miguel Bernal
Diagnosing lithium‐ion battery degradation is a crucial part of managing energy storage systems. Recent research has explored ultrasonic testing for non‐invasive health assessment as an alternative to traditional, time‐consuming, electrical‐only methods. Assessing the state of health is vital for determining quality at end of ‘first’ life, with retired batteries at 70–80 % health still holding value for secondlife applications. Over the coming years, tens of GWh of salvaged batteries will hit the market, requiring rapid noninvasive methods to classify retired batteries according to their state of health. This study uses a 64 – element ultrasonic array to obtain mid‐band quantitative ultrasound spectroscopy parameters – including mid‐band fit, spectral slope, and intercept – from circumferential waves around cylindrical batteries. Thirteen cylindrical cells were used to evaluate the methodology: three pristine and ten retired from the same source. The mid‐band fit showed the ability to track the state of charge and discriminate between the state of health levels in accelerated degradation experiments both with pristine batteries, and also with recovered secondlife batteries with unknown historical use. Linear‐array ultrasonic transducers, coupled with quantitative spectral parameters, show promise for future non‐destructive battery health screening methods, offering valuable insights for the emerging used battery market.

4 March 2015 in Connective Tissue Research
Verified
Journal Article
Closed access
DRDaniel Rohrbach
Daniel Rohrbach
QGQuentin Grimal
Quentin Grimal
PVPeter Varga
Peter Varga
FPFrancoise Peyrin
Francoise Peyrin
MLMax Langer
Max Langer
KRKay Raum
Kay Raum
Cortical bone properties are determined by tissue composition and structure at several hierarchical length scales. In this study, the spatial distribution of micro- and mesoscale elastic properties within a human femoral shaft has been investigated. Microscale tissue degree of mineralization (DMB), cortical vascular porosity Ct.Po and the average transverse isotropic stiffness tensor C(Micro) of cylindrical-shaped samples (diameter: 4.4 mm, N = 56) were obtained from cortical regions between 20 and 85% of the total femur length and around the periphery (anterior, medial, posterior and lateral quadrants) by means of synchrotron radiation µCT (SRµCT) and 50-MHz scanning acoustic microscopy (SAM). Within each cylinder, the volumetric bone mineral density (vBMD) and the mesoscale stiffness tensor C(Meso) were derived using a numerical homogenization approach. Moreover, microelastic maps of the axial elastic coefficient c33 measured by SAM at distinct cross-sectional locations along the femur were used to construct a 3-D multiscale elastic model of the femoral shaft. Variations of vBMD (6.1%) were much lower than the variations of mesoscale elastic coefficients (11.1-21.3%). The variation of DMB was only a minor predictor for variations of the mesoscale elastic properties (0.05 ≤ R(2) ≤ 0.34). Instead, variations of the mesoscale elastic properties could be explained by variations of cortical porosity and microscale elastic properties. These data were suitable inputs for numerical evaluations and may help to unravel the relations between structure and composition on the elastic function in cortical bone.

1 January 2012 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
BPBernd Preininger
Bernd Preininger
BHBernhard Hesse
Bernhard Hesse
DRDaniel Rohrbach
Daniel Rohrbach
PVPeter Varga
Peter Varga
HGHinnerk Gerigk
Hinnerk Gerigk
KRKay Raum
Kay Raum
Contrast between not fully mineralized tissues is weak and limits conventional computed tomography (CT). An automated grayscale histogram-based analysis features could improve the sensitivity to tissue alterations during early bone healing. Tissue formation in a rat osteotomy model was analyzed using in vivo micro-CT and classified histologically (mineralized, cartilage, and connective tissues). A conventional threshold-based method including manual contouring was compared to a novel moment-based method: after removing the background peak, the histograms of each slice were characterized by their moments and analyzed as a function of the position along the long bone axis. The threshold-based method could differentiate between the mineralized and connective tissue (R = 0.73). The moment-based approach yielded a clear distinction between all 3 groups with a classification accuracy up to R = 0.93. The moment-based evaluation outperforms the conventional threshold-based CT analysis in sensitivity to the healing stage, user independence, and time consumption.

1 September 2017
Verified
Conference Paper
Open access
Jae-Hoon KimJae-Hoon Kim
Jae-Hoon Kim
PHP.R. Hill
P.R. Hill
NCN. Canagarajah
N. Canagarajah
DRD. Rohrbach
D. Rohrbach
DKD. Kouame
D. Kouame
ABA. Basarab
A. Basarab
Scanning acoustic microscopy is a well-accepted modality for forming quantitative 2D maps of acoustic properties of soft tissues at microscopic scales. In our studies, the sample is raster-scanned with a spatial step size of 2 μm using a 250 MHz transducer resulting in 3D RF data cubes. Each RF signal is processed to obtain, for each spatial location, acoustic parameters, e.g., the speed of sound. The scanning time is directly dependent on the sample size and can range from few minutes to hours. In order to maintain constant experimental conditions for the sensitive thin sectioned samples, the scanning time is an important practical issue. Hence, the main objective of this work is to reduce the scanning time by reconstructing acoustic microscopy images from spatially under sampled measurements, based on the theory of compressive sampling. A recently proposed approximate message passing method using a Cauchy maximum a posteriori image denoising algorithm is thus employed to account for the non-Gaussianity of quantitative acoustic microscopy wavelet coefficients.