Currently, photoplethysmography (PPG) is a frequently studied optical blood pulsation detection technique among biophotonic and biomedical researchers due to the fact that it shows high potential for estimating the arterial stiffness (AS). The extraction of diagnostically useful information requires standardized measurement procedure with good repeatability. However, the effects of a crucially important factor—the optimal contact pressure (CP) of the probe—are often ignored. Also, CP values are not reported to evaluate those effects. It is hypothesized that AS estimated from PPG pulse wave 2nd derivative parameter is strongly inconsistent when recorded at nonoptimal probe CP. Our pilot study confirmed this during in vivo PPG recordings from conduit artery sites on five healthy subjects at variable probe CP (0 to 15 kPa) by using 880 nm reflectance type sensor, force transducer, and PPG alternating current (AC) signal pulse area derived optimal CP criterion. The values, calculated from PPG with variable CP, showed variation . In contrast, at the optimal CP, the showed high repeatability (coefficient of variability ). The effect has been explained with exponential pulse pressure-volume relationship model which indicates the optimal CP range.
16 May 2019 in Intensive Care Medicine Experimental
Conduit arteries, especially the aorta, play a major role in ensuring efficient cardiac function and optimal microvascular flow due to their viscoelastic properties. Studies in animals and on isolated arteries show that acute systemic inflammation can cause aortic stiffening which affects hemodynamic efficiency. Carotid-femoral pulse wave velocity, a measure of aortic stiffness, may be useful as a bedside investigational method in patients with early sepsis admitted to intensive care, as circulatory changes can lead to multiple organ failure and increased mortality. This study aims to investigate arterial stiffness in early sepsis and its association with clinical outcomes. This prospective observational study included adult patients with severe sepsis or septic shock admitted to our intensive care unit (n = 45). Their carotid-femoral pulse wave velocity was measured within 24 h of admission. We assessed the progression of multiple organ as well as cardiovascular failure by sequential SOFA scores. Prediction models for the progression of multiple organ and cardiovascular failure were constructed using multivariate logistic regression with pulse wave velocity and vasopressor use as predictors. A Cox proportional hazards model was used to examine the relationship between pulse wave velocity and survival time. The median pulse wave velocity for the cohort was 14.6 (8.1–24.7) m/s. There was no association between pulse wave velocity and the progression of multiple organ failure, before or after adjustment for vasopressor use. No association was found between pulse wave velocity and subsequent improvement in cardiovascular failure in the subgroup of patients who had cardiovascular instability at baseline. Cox regression and survival analyses with age, APACHE II, and baseline SOFA as confounders showed a shorter hospital survival time for patients with pulse wave velocity > 24.7 m/s (HR = 9.45, 95% CI 1.24–72.2; P = 0.03). Patients with severe sepsis and septic shock admitted to intensive care have higher arterial stiffness than in the general population. No convincing association was found between pulse wave velocity at admission and the progression of multiple organ or cardiovascular failure, although the group with pulse wave velocity > 24.7 m/s had shorter survival time.
The present study introduces a recently developed compact hybrid device for real-time monitoring of skin oxygen saturation and temperature distribution. The prototype involves a snapshot hyperspectral camera, multi-wavelength illuminator, thermal camera, and built-in computer with custom-developed software. To validate this device in-vivo we performed upper arm vascular occlusion on eight healthy volunteers. Palm skin oxygen saturation maps were analyzed in real-time using k-means segmentation algorithm and two-layer optical diffuse model. The prototype system demonstrated a satisfying performance of skin hyperspectral measurements in the spectral range of 507–625 nm. The results confirmed the reliability of the proposed system for in-vivo assessment of skin hemoglobin saturation with oxygen and microcirculation.
About 2% of the world’s population suffers from small nerve fiber dysfunction, neuropathy, which can result in severe pain. This condition is caused by damage to the small nerve fibers and its assessment is challenging, due to the lack of simple and objective diagnostic techniques. The present study aimed to develop a contactless photoplethysmography system using simple instrumentation, for objective and non-invasive assessment of small cutaneous sensory nerve fiber function. The approach is based on the use of contactless photoplethysmography for the characterization of skin flowmotions and topical heating evoked vasomotor responses. The feasibility of the technique was evaluated on volunteers (n = 14) using skin topical anesthesia, which is able to produce temporary alterations of cutaneous nerve fibers function. In the treated skin region in comparison to intact skin: neurogenic and endothelial component of flowmotions decreased by ~61% and 41%, the local heating evoked flare area decreased by ~44%, vasomotor response trend peak and nadir were substantially reduced. The results indicate for the potential of the remote photoplethysmography in the assessment of the cutaneous nerve fiber function. It is believed that in the future this technique could be used in the clinics as an affordable alternative to laser Doppler imaging technique.
Skin capillary blood oxygen saturation is a clinically important diagnostic parameter, which provides valuable information for timely treatment of pathological conditions e.g. sepsis, hypoxemia or decompression illness. Hyperspectral imaging is non-invasive optical techniques with high clinical potential, however its use for skin blood oxygen saturation detection is still challenging, therefore in the present study, a method for in-vivo manipulation of skin oxygen saturation was developed, and reliability of the method evaluated by means of hyperspectral imaging in detection of oxygen saturation. In order to produce alterations of skin capillary blood parameters and oxygen saturation, the proximal phalanx of the right middle finger was occluded with a pneumatic cuff for 25 minutes. During the last minute of occlusion, the hyperspectral cubes (HIS) of both occluded and intact finger were captured, and capillary blood sample was collected for analysis with portable whole blood analyzer (REF). The group mean values for SaO2 in intact finger skin was HIS: 89.46%±8.79% versus REF: 95.13±1.46 % and in occluded finger HSI: 25.85% ±14.00%, versus REF: 22.73±9.09 % displaying a small difference between two independent techniques, which indicate the reliability of finger occlusion model.
Background and Objectives: Sepsis, a leading global health challenge, accounts for around 20% of deaths worldwide. The complexity of sepsis, especially the difference between bacterial and viral etiologies, requires an effective assessment of microcirculation during resuscitation. This study aimed to evaluate the impact of infusion therapy on microcirculation in patients with sepsis, focusing on bacterial- and COVID-19-associated sepsis using remote photoplethysmography (rPPG) and the automated capillary refill time (aCRT). Materials and Methods: This single-center prospective study was conducted in the ICU of Pauls Stradins Clinical University Hospital, including 20 patients with sepsis/septic shock. The patients were selected based on hemodynamic instability and divided into COVID-19 and Bacterial Septic Shock groups. Fluid responsiveness was assessed using the Passive Leg Raising Test (PLRT). Systemic hemodynamics and microcirculation were monitored through MAP CRT, rPPG, and serum lactate levels. Statistical analyses compared responses within and between the groups across different stages of the protocol. Results: The Bacterial group exhibited higher initial serum lactate levels and more pronounced microcirculatory dysfunction than the COVID-19 group. rPPG was more sensitive in detecting perfusion changes, showing significant differences between the groups. The automated CRT demonstrated greater sensitivity compared to the manual CRT, revealing significant differences during PLRT stages between bacterial- and COVID-19-associated sepsis. Both groups had a transient hemodynamic response to PLRT, with subsequent stabilization upon fluid infusion. Conclusions: When managing patients with sepsis in intensive care, monitoring microcirculation is of paramount importance in infusion therapy. Our study highlights the potential of rPPG and aCRT as tools for this purpose. These techniques can be used in conjunction with routine parameters, such as lactate levels and systemic hemodynamic parameters, to provide a comprehensive assessment of a patient’s condition.