Nicol E. McGruer

Nicol E. McGruer

Auto-generated profile, based on publicly available information

Nicol E. McGruer

Department of Electrical and Computer Engineering, Northeastern University, Boston, MA, USA

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
VRVageeswar Rajaram
Vageeswar Rajaram
ZQZhenyun Qian
Zhenyun Qian
SKSungho Kang
Sungho Kang
SCSila Deniz Calisgan
Sila Deniz Calisgan
NMNicol E. McGruer
Nicol E. McGruer
MRMatteo Rinaldi
Matteo Rinaldi
Micromechanical photoswitches (MPs) have shown orders of magnitude lower standby power consumption compared to their solid-state technology-based counterparts. In this paper, we demonstrate that the infrared detection threshold (i.e., the lowest detectable power of incident infrared radiation) of this new type of photoswitch can be effectively decreased by applying a bias voltage across the switch without compromising its key feature of near-zero standby power consumption and low false-alarm rate. We show that by exploiting the electrostatic pull-in effect (using bias voltage of ~7 V), a threshold as low as 76 nW can be achieved, which is the lowest threshold demonstrated to date for MPs. A mathematical model predicting the device threshold under a bias voltage is derived and verified by experiments. Furthermore, the effects of the bias on the device's stability are carefully studied suggesting the existence of a tradeoff between the detection threshold and the false-alarm rate when the bias is higher than 85% of the pull-in voltage. The source of the instability that causes false alarms is found to originate from charge accumulation over time in the dielectric substrate surrounding the bottom contact, which we believe can be mitigated by an improved contact design. Another effect associated with high bias is the contact stiction after infrared-triggered pull-in. To address this, a microheater is integrated into the switch to reopen the contacts while consuming only ~0.5 μJ per operation. This paper thus presents an effective solution for post-fabrication threshold adjustment of MPs, which is useful for applications requiring variable thresholds.

8 June 1998
Verified
Conference Paper
Open access
NMN.E. McGruer
N.E. McGruer
PZP.M. Zavracky
P.M. Zavracky
SMS. Majumder
S. Majumder
GAG.G. Adams
G.G. Adams
RMR. Morrison
R. Morrison

14 November 1999
Verified
Conference Paper
Closed access
PDF file
TTThieu Q. Truong
Thieu Q. Truong
TBTerrence G. Barnes
Terrence G. Barnes
Xiaoqing LuXiaoqing Lu
Xiaoqing Lu
GAGeorge G. Adams
George G. Adams
NMNicol E. McGruer
Nicol E. McGruer
Contact/bending sensors have been designed, analyzed, fabricated, and tested. These sensors are to be mounted on flexible antennae in order to provide a sense of touch for ambulatory underwater robotic lobsters. These biomimetic vehicles are designed to mimic some of the behavior patterns of real lobsters and are being built in order to search for and destroy mines in the littoral zone [1]. Two contact/bending sensors have been developed — a “standard” sensor and a “stopper” sensor. The standard sensor and stopper sensor are cantilever beam type microswitches fabricated on a thin flexible substrate. These sensors were fabricated using the Northeastern University Metal Micromachining (NUMEM) process [2]. The purpose of the stopper sensor design is to increase the dynamic range and alleviate the sensitivity limitations that are inherent in the standard sensor design. Tests have shown the standard sensors close at a substrate radius of curvature that is 25% greater than the design values. Tests and SEM micrographs of the stopper sensors have shown that there are some processing issues which need to be addressed.